1 
    2 
    3 
    4 
    5 
    6 
    7 
    8 
    9 
   10 
   11 
   12               MULTICS MR12.7 ERROR MESSAGE DOCUMENTATION
   13 
   14                          February 17, 2020^L
   15 
   16 
   17 INTRODUCTION
   18 
   19      This  document  has  been  prepared  automatically  from the
   20 system source by Multics Software Support.  Every effort has been
   21 made  to supply  documentation for  each and  every message  that
   22 could appear either on the system console, or in the system logs.
   23 However,  some of the  system messages are  not provided in  this
   24 document due  to the messages developed prior  to the development
   25 of  the  error  messages  document,  or  omitted  in  error.  The
   26 following is a list of modules  that are known to be missing from
   27 this document:
   28 
   29 
   30 as_access_audit_.pl1             monitor_cache.pl1
   31 as_any_other_handler_.pl1        mos_edac_summary.pl1
   32 as_ibm3270_mpx_.pl1              mos_edac_summary.pl1
   33 as_send_user_mail_.pl1           mpc_data_summary.pl1
   34 as_send_user_message_.pl1        mseg_error_v3_.pl1
   35 as_uncp_mpx_.pl1                 mseg_error_v4_.pl1
   36 as_vip7760_mpx_.pl1              multiplexer_mgr_.pl1
   37 asr_com_channel_info_srvr_.pl1   pc_recover_sst.pl1
   38 asum_error_.pl1                  pdir_volume_manager_.pl1
   39 bootload_fs_.pl1                 poll_fnp.pl1
   40 cancel_abs_request.pl1           poll_mpc.pl1
   41 dir_dump.pl1                     polled_vip_mpx.pl1
   42 display_cpu_error.pl1            print_syserr_msg_.pl1
   43 display_cpu_error.pl1            print_syserr_msg_.pl1
   44 ec_shift_config_change_.pl1      protocol_mpx.pl1
   45 emergency_shutdown.alm           rcp_mount_timer_poll_.pl1
   46 extract_msg_doc_.pl1             rcp_pre_claim_.pl1
   47 find_rpv_subsystem.pl1           rcprm_verify_registries_.pl1
   48 fnp_data_summary.pl1             read_disk_label.pl1
   49 hc_device_acct_.pl1              salv_directory.pl1
   50 hc_tune.pl1.pmac                 salv_err_msg.pl1
   51 hc_tune.pl1.pmac                 salvager.pl1
   52 heals_collect_data_.pl1          sc_admin_mode_.pl1
   53 initial_error_handler.pl1        sys_log_.pl1
   54 initial_error_handler.pl1        syserr.alm
   55 install_ttt_.pl1                 syserr_log_daemon.pl1
   56 io_error_summary.pl1             tty_read.pl1
   57 io_error_summary.pl1             uc_create_process_.pl1
   58 io_reconfig.pl1                  uc_create_process_check_.pl1
   59 ioi_page_table.pl1               uc_dial_.pl1
   60 iom_switches.pl1                 uc_list_disconnected_procs_.pl1
   61 level_error.pl1                  uc_login_.pl1
   62 list_abs_requests.pl1            uc_logout_.pl1
   63 ls_request_server_.pl1           uc_ls_create_request_.pl1
   64 mc_check_acs_.pl1                uc_ls_destroy_request_.pl1
   65 mc_con_rec_.pl1                  uc_ls_dial_request_.pl1
   66 mc_wakeups_.pl1                  uc_ls_disconnect_request_.pl1
   67 mcs_timer_daemon.pl1             uc_ls_list_request_.pl1
   68 mdc_check_mdcs_.pl1              uc_ls_logout_request_.pl1
   69 monitor_cache.pl1                uc_ls_new_proc_request_.pl1
   70 
   71 
   72                                 2             08/21/20     MR12.7^L
   73 
   74 
   75 uc_ls_operator_request_.pl1      uc_setup_process_connect_.pl1
   76 uc_ls_process_request_.pl1       uncp.pl1
   77 uc_ls_rq_server_wakeup_.pl1      uncp_boot_interrupt.pl1
   78 uc_ls_validate_request_.pl1      uncp_multiplexer.pl1
   79 uc_proc_term_handler_.pl1        uncp_util.pl1
   80 uc_send_ls_response_.pl1         up_cdt_.pl1
   81 uc_set_pit_tty_info_.pl1         user_table_mgr_.pl1
   82 
   83 EXPLANATION OF ERROR MESSAGES
   84 
   85      For each message,  an example of the text of  the message is
   86 provided, followed by four  paragraphs:  Severity, Time, Meaning,
   87 and Action.
   88 
   89 Message Example
   90 
   91      The message example  is a literal copy of  the message, with
   92 substitutable fields  shown in all capitals.   Each substitutable
   93 field is described in the Meaning paragraph.
   94 
   95 Output
   96 
   97      The output  field describes how the message  is output.  For
   98 hardcore  messages  it  shows  the  interpretation  of  the first
   99 argument to SYSERR, which  determines whether the system crashes,
  100 sounds  the  beeper,  etc.   For  answering  service messages, it
  101 describes the output stream and source.
  102 
  103 Time
  104 
  105      The  time section  describes the  time when  the message  is
  106 possible.
  107 
  108 Meaning
  109 
  110      The meaning paragraph describes  the situation that prompted
  111 the  message and the  probable cause of  the situation.  It  then
  112 describes  the  consequences  of  the  situation.   Substitutable
  113 parameters in the message example are explained here.
  114 
  115 Action
  116 
  117      The  action  paragraph  describes  what  operator  action is
  118 required when the message occurs.
  119 
  120 
  121 
  122 
  123 
  124 
  125 
  126 
  127 
  128 
  129 
  130                                 3             08/21/20     MR12.7^L
  131 
  132 
  133                [rldr_arg_reader_.pl1]
  134                rldr_arg_reader_:  Implementation Restriction, the
  135                RPV  must  be  reloaded  separately  to obtain the
  136                required physical volume information.
  137 
  138 
  139 
  140      Stream:   BOS Typewriter.
  141 
  142      Time:     While system is running.
  143 
  144      Meaning:  Due to an implementation restriction, the RPV must
  145                be  reloaded separately   from the  other physical
  146                volumes.  Reload the RPV first, then re-invoke the
  147                reload_volue  command  with   the  other  physical
  148                volume names to be reloaded.
  149 
  150      Action:   Enter a corrected command line.
  151 
  152 
  153                [scas_init.pl1]
  154                "scas_init:   MEM Y.   Tags greater  than "D"  not
  155                supported by DPS8 CPUs",
  156 
  157 
  158      Stream:   BOS Typewriter (Crashes system)
  159 
  160      Time:     System Intialization.
  161 
  162      Meaning:  The  physical configuration  or the  configuration
  163                deck is  incorrect.  DPS8 CPUs have  only 4 memory
  164                ports, therefore Multics systems comprised of DPS8
  165                cpus or  mixed systems of  DPS, L68 and  DPS8 cpus
  166                can  only  have   4  memories  configured.   (i.e.
  167                Memory tags A, B, C, and D).
  168 
  169      Action:   Correct  the  physical  configuration  and/or  the
  170                configuration deck and reboot.
  171 
  172 
  173                [sc_process_command_line_.pl1]
  174                (input on SWITCH_NAME) REQUEST_LINE
  175 
  176 
  177      Stream:   as (severity 0)
  178 
  179      Time:     In response to an operator command.
  180 
  181      Meaning:  Logs a  REQUEST_LINE typed by the  operator, or by
  182                another   user  via   the  send_admin_command   or
  183                send_initializer_command commands.
  184 
  185      Action:   No operator action is required.
  186 
  187 
  188 abs ACTION                      4             08/21/20     MR12.7^L
  189 
  190 
  191 
  192 
  193                [absentee_utility_.pl1]
  194                abs ACTION:  N requests ACTIONed.
  195 
  196 
  197      Stream:   as (severity1)
  198 
  199      Time:     In  response  to  an  abs  defer  or  abs  release
  200                command.
  201 
  202      Meaning:  Indicates  success  or  failure  of  the  command.
  203                ACTION can be defer or  release, and N can be "no"
  204                or the number of requests acted upon.
  205 
  206      Action:   Confirm that the expected results were obtained.
  207 
  208 
  209                [absentee_utility_.pl1]
  210                abs  run:   job   selection  arguments  matched  N
  211                requests; be more specific.
  212 
  213 
  214      Stream:   as (severity1)
  215 
  216      Time:     In response to an abs run command.
  217 
  218      Meaning:  The  specified arguments  matched either  zero, or
  219                more than one, request, and so no job was run.
  220 
  221      Action:   Re-enter  the command  with correct  arguments, to
  222                select exactly one job for running.
  223 
  224 
  225 
  226                [absentee_utility_.pl1]
  227                abs run:  request PATH ID is already running.
  228 
  229 
  230      Stream:   as (severity1)
  231 
  232      Time:     In response to an abs run command.
  233 
  234      Meaning:  The specified job is already running.
  235 
  236      Action:   If  a  mistake  was   made,  repeat  the  command,
  237                specifying the correct job.
  238 
  239 
  240                [absentee_user_manager_.pl1]
  241                absentee_user_manager_  (abs   run):   System  too
  242                full; no absentee jobs can be started now.
  243 
  244 
  245 
  246 absentee_user_manager_ (abs run)5             08/21/20     MR12.7^L
  247 
  248 
  249      Stream:   as (severity1)
  250 
  251      Time:     In response to an abs run command.
  252 
  253      Meaning:  The system  is too near the upper  limit on logged
  254                in users to start any absentee jobs.
  255 
  256      Action:   If the immediate running  of the job is essential,
  257                use  "abs  stop  queue  all"  to  halt  all  other
  258                absentee logins, change the login word to halt all
  259                interactive logins, and either  wait for a process
  260                to log out, or bump  one, before repeating the abs
  261                run command.
  262 
  263 
  264 
  265                [absentee_user_manager_.pl1]
  266                absentee_user_manager_$init:    MESSAGE.    Cannot
  267                truncate absentee_user_table.
  268 
  269 
  270      Stream:   as (severity1)
  271 
  272      Time:     System Intialization.
  273 
  274      Meaning:  It    was    not    possible    to    clear    the
  275                absentee_user_table segment.
  276 
  277      Action:   Contact the system programming staff.
  278 
  279 
  280                [absentee_user_manager_.pl1]
  281                absentee_user_manager_:    ERROR   attempting   to
  282                cancel reservation R for USER.PROJ absN
  283 
  284 
  285      Stream:   as (severity1)
  286 
  287      Time:     While system is running.
  288 
  289      Meaning:  The  system  was  unable   to  cancel  a  resource
  290                reservation for an absentee  process that is being
  291                destroyed.     The   resource(s)    might   remain
  292                unavailable to other users.  There is some problem
  293                in the resource reservation mechanism.
  294 
  295      Action:   Contact the system programming staff.
  296 
  297 
  298                [absentee_user_manager_.pl1]
  299                absentee_user_manager_:    ERROR   attempting   to
  300                pre-claim reservation R for USER.PROJ absN
  301 
  302 
  303 
  304 absentee_user_manager_          6             08/21/20     MR12.7^L
  305 
  306 
  307      Stream:   as (severity1)
  308 
  309      Time:     While system is running.
  310 
  311      Meaning:  The  system  was  unable   to  assign  a  resource
  312                reservation  to  an  absentee  job  that  is being
  313                logged in.  The job will be run, but it might fail
  314                if the resources it needs happen to be unavailable
  315                when it  requests them.  There is  some problem in
  316                the resource reservation mechanism.
  317 
  318      Action:   Contact the system programming staff.
  319 
  320 
  321                [absentee_user_manager_.pl1]
  322                absentee_user_manager_:   Error   in  initializing
  323                absentee.  Don't bring up absentee facility
  324 
  325 
  326      Stream:   as (severity1)
  327 
  328      Time:     While system is running.
  329 
  330      Meaning:  The absentee mechanism will not initialize.
  331 
  332      Action:   Contact the system programming  staff.  Do _^Hn_^Ho_^Ht try
  333                to initialize the absentee facility.
  334 
  335 
  336 
  337                [absentee_user_manager_.pl1]
  338                absentee_user_manager_:  Error:  CONDITION
  339 
  340 
  341      Stream:   as (severity2)
  342 
  343      Time:     While system is running.
  344 
  345      Meaning:  An unexpected fault  has occurred while performing
  346                some  absentee function such  as logging in  a new
  347                absentee user.  The  system automatically performs
  348                an Answering Service dump and attempts to recover.
  349 
  350      Action:   No  action   is  required  unless   the  condition
  351                persists.  If this  message occurs repeatedly, try
  352                stopping   the  absentee   facility;  inform   the
  353                programming staff.
  354 
  355 
  356 
  357                [absentee_user_manager_.pl1]
  358                absentee_user_manager_:    ERROR_MESSAGE.   Cannot
  359                create absentee event channel
  360 
  361 
  362 absentee_user_manager_          7             08/21/20     MR12.7^L
  363 
  364 
  365      Stream:   as (severity2)
  366 
  367      Time:     System Intialization.
  368 
  369      Meaning:  The absentee facility could not create part of its
  370                communications mechanism.  No absentee process can
  371                be logged in.
  372 
  373      Action:   Try the abs start  command again.  If the absentee
  374                facility  still  fails,   inform  the  programming
  375                staff.
  376 
  377 
  378 
  379                [absentee_user_manager_.pl1]
  380                absentee_user_manager_:   ERROR_MESSAGE.  Creating
  381                proc for NAME.PROJ
  382 
  383 
  384      Stream:   as (severity2)
  385 
  386      Time:     While system is running.
  387 
  388      Meaning:  A storage system error prevented the absentee user
  389                from logging in.  This is due to some error in the
  390                process  creating  mechanism.   The  user  is  not
  391                logged in.
  392 
  393      Action:   Contact the  system programming staff.   Shut down
  394                the absentee facility with an  abs bump * * and an
  395                abs stop if this message occurs repeatedly.
  396 
  397 
  398 
  399                [absentee_user_manager_.pl1]
  400                absentee_user_manager_:  ERROR_MESSAGE.  Trying to
  401                wakeup   PERSON.PROJECT.TAG   process   after  abs
  402                release.
  403 
  404 
  405 
  406      Stream:   as (severity 0)
  407 
  408      Time:     Called  in  response  to  an  operator abs release
  409                command.
  410 
  411      Meaning:  A failure  occurred while sending a  wakeup to the
  412                absentee process being released.  ERROR_MESSAGE is
  413                the text  associated with the error  code returned
  414                by hcs_$wakeup.
  415 
  416      Action:   No operator action is required.
  417 
  418 
  419 
  420 absentee_user_manager_          8             08/21/20     MR12.7^L
  421 
  422 
  423 
  424 
  425                [absentee_user_manager_.pl1]
  426                absentee_user_manager_:  event calls were masked.
  427 
  428 
  429      Stream:   sc (user_output)
  430 
  431      Time:     While system is running.
  432 
  433      Meaning:  This  message  indicates  a  serious  error in the
  434                Initializer  programs.   The  system  attempts  to
  435                recover and keep running.
  436 
  437      Action:   Contact the system programming staff.
  438 
  439 
  440                [absentee_user_manager_.pl1]
  441                absentee_user_manager_:  Premature stopstop for ID
  442 
  443 
  444      Stream:   as (severity0)
  445 
  446      Time:     While system is running.
  447 
  448      Meaning:  An error has occurred  while trying to destroy the
  449                absentee  process  ID.   The  system  recovers and
  450                continues.
  451 
  452      Action:   No operator action is required.
  453 
  454 
  455                [absentee_user_manager_.pl1]
  456                absentee_user_manager_:      Process    terminated
  457                USER.PROJ ID MESSAGE.
  458 
  459 
  460      Stream:   as (severity0)
  461 
  462      Time:     While system is running.
  463 
  464      Meaning:  The   absentee  process    ID  of   USER.PROJ  has
  465                terminated for  the reason specified, and  will be
  466                logged out.
  467 
  468      Action:   No operator action is required.
  469 
  470 
  471                [absentee_user_manager_.pl1]
  472                absentee_user_manager_:   Strange   event  message
  473                WWWWWWWWWWWW    WWWWWWWWWWWW   from    user   proc
  474                WWWWWWWWWWWW
  475 
  476 
  477 
  478 absentee_user_manager_          9             08/21/20     MR12.7^L
  479 
  480 
  481      Stream:   as (severity1)
  482 
  483      Time:     While system is running.
  484 
  485      Meaning:  This message  is similar to the  preceding message
  486                described above,  except that the signal  does not
  487                come  from  the  Initializer  but  from some other
  488                process.  The process ID of the sending process is
  489                printed  in octal.   The event  message was  not a
  490                valid  item.  The  system ignores  the signal  and
  491                goes on.
  492 
  493      Action:   If absentee  jobs will no  longer run, try  an abs
  494                stop  and   an  abs  start.   Inform   the  system
  495                programming staff.
  496 
  497 
  498 
  499                [absentee_user_manager_.pl1]
  500                absentee_user_manager_:   Strange   event  message
  501                WWWWWWWWWWWW WWWWWWWWWWWW from Initializer
  502 
  503 
  504      Stream:   as (severity1)
  505 
  506      Time:     While system is running.
  507 
  508      Meaning:  An unrecognizable event  message has been received
  509                from the Answering Service.   Its value is printed
  510                in octal.  Usually, the first word is the function
  511                code  and the  second word   is the  index in  the
  512                absentee user  table.  This condition is  due to a
  513                error  in   the  Answering  Service   or  absentee
  514                programs.  The system ignores  the signal and goes
  515                on.  The absentee facility may cease to operate.
  516 
  517      Action:   If absentee  jobs will no  longer run, try  an abs
  518                stop  and   an  abs  start.   Inform   the  system
  519                programming staff.
  520 
  521 
  522 
  523                [absentee_user_manager_.pl1]
  524                absentee_user_manager_:   Strange   event  message
  525                WWWWWWWWWWWW WWWWWWWWWWWW from NAME.PROJ TTY
  526 
  527 
  528      Stream:   as (severity1)
  529 
  530      Time:     While system is running.
  531 
  532      Meaning:  This message is similar  to the preceding message,
  533                except that the name, project, and tty name of the
  534 
  535 
  536 absentee_user_manager_          10            08/21/20     MR12.7^L
  537 
  538 
  539                user sending  the wakeup are printed.   The system
  540                ignores the signal and goes on.
  541 
  542      Action:   No operator action is required.
  543 
  544 
  545                [absentee_user_manager_.pl1]
  546                absentee_user_manager_:  Trace ....
  547 
  548 
  549      Stream:   as (severity1)
  550 
  551      Time:     While system is running.
  552 
  553      Meaning:  This is trace output.   It begins coming out about
  554                every          five         minutes          after
  555                absentee_user_manager_$aum_trace_on is called.
  556 
  557      Action:   No  operator  action  is  required.   To shut this
  558                message                 off,                 type:
  559                absentee_user_manager_$aum_trace_off    while   in
  560                admin mode.
  561 
  562 
  563 
  564                [absentee_utility_.pl1]
  565                absentee_utility_ (abs run):  Request PATH ID will
  566                be  run  in   spite  of  unavailable  resource(s):
  567                RESOURCE
  568 
  569 
  570      Stream:   as (severity1)
  571 
  572      Time:     In response to an abs run command.
  573 
  574      Meaning:  The  job selected  by  the  abs run  command needs
  575                RESOURCE, which  is unavailable.  The job  will be
  576                logged in anyway.
  577 
  578      Action:   If the job is critical, the resource could be made
  579                available  by force  detaching it  from some other
  580                process.  This is a drastic action, and should not
  581                be   taken  without  the   System  Administrator's
  582                approval.
  583 
  584 
  585 
  586                [absentee_utility_.pl1]
  587                absentee_utility_  (setup_queue):   Invalid  queue
  588                number:  QUEUE
  589 
  590 
  591      Stream:   as (severity2)
  592 
  593 
  594 absentee_utility_ (setup_queue) 11            08/21/20     MR12.7^L
  595 
  596 
  597      Time:     While system is running.
  598 
  599      Meaning:  The internal queue number in absentee_utility_ was
  600                invalid when trying to  find an absentee to login.
  601                If  this  occurs,  there   is  a  logic  error  in
  602                absentee_utility_.
  603 
  604      Action:   Contact the system programming staff.
  605 
  606 
  607                [absentee_utility_.pl1]
  608                absentee_utility_:      >sc1>absentee_data     has
  609                overflowed its limit of N entries.
  610 
  611 
  612      Stream:   as (severity2)
  613 
  614      Time:     While system is running.
  615 
  616      Meaning:  The  absentee facility  keeps a  list of  absentee
  617                jobs  that   are  either  deferred   or  currently
  618                running.  This list has a capacity of about 13,000
  619                entries.  It is extremely  unlikely that this data
  620                area  will fill  up unless  some user  program has
  621                entered a loop and is submitting requests for jobs
  622                faster than the jobs are being run.
  623 
  624      Action:   Contact the system programming staff.
  625 
  626 
  627                [absentee_utility_.pl1]
  628                absentee_utility_:   >sc1>absentee_data   will  be
  629                rebuilt.
  630 
  631 
  632      Stream:   as (severity1)
  633 
  634      Time:     While system is running.
  635 
  636      Meaning:  An  attempt will  be made  to rebuild  the request
  637                lists  in  absentee_data   to  correct  the  error
  638                reported by the previous message.
  639 
  640      Action:   Note for system programmer action.
  641 
  642 
  643                [absentee_utility_.pl1]
  644                absentee_utility_:  Absentee processing suspended.
  645                Contact system programmer.
  646 
  647 
  648      Stream:   as (severity2)
  649 
  650 
  651 
  652 absentee_utility_               12            08/21/20     MR12.7^L
  653 
  654 
  655      Time:     While system is running.
  656 
  657      Meaning:  Absentee processing has  been suspended because of
  658                the error  described in the previous  message.  No
  659                more jobs will be started, but logged in jobs will
  660                continue running.   The absentee facility  has not
  661                been stopped,  and an "abs start"  command will be
  662                rejected.  After the error has been corrected, the
  663                "abs start queue N" command  may be used to resume
  664                the processing of  requests from queues unaffected
  665                by the error.
  666 
  667      Action:   Contact the system programming staff.
  668 
  669 
  670                [absentee_utility_.pl1]
  671                absentee_utility_:  Attempt to  set defer timer to
  672                time in past (TIME).  Setting  it to a minute from
  673                now.
  674 
  675 
  676      Stream:   as (severity0)
  677 
  678      Time:     While system is running.
  679 
  680      Meaning:  An attempt  was made to set  the absentee deferred
  681                request timer to a time in the past.
  682 
  683      Action:   No operator action is required.
  684 
  685 
  686                [absentee_utility_.pl1]
  687                absentee_utility_:  Attempting to reserve RESOURCE
  688                for PERS.PROJ (PATH)
  689 
  690 
  691      Stream:   as (severity2)
  692 
  693      Time:     While system is running.
  694 
  695      Meaning:  An error occurred during  the attempt to reserve a
  696                resource for an absentee job.  The job is deferred
  697                and  the  attempt  to   reserve  the  resource  is
  698                repeated  at   some  later  time.    The  absentee
  699                facility continues to operate.  There is something
  700                wrong with  the resource reservation  mechanism or
  701                with some other part of RCP.
  702 
  703      Action:   Contact the system programming staff.
  704 
  705 
  706                [absentee_utility_.pl1]
  707 
  708 
  709 
  710 absentee_utility_               13            08/21/20     MR12.7^L
  711 
  712 
  713                absentee_utility_:   BUG:   lc  ineligible (INDEX)
  714                not at head of resource list.
  715 
  716 
  717      Stream:   as (severity2)
  718 
  719      Time:     While system is running.
  720 
  721      Meaning:  The  current  absentee  request,  which  would  be
  722                deferred by  load control, is  not at the  head of
  723                the  absentee list.   If this  occurs, there  is a
  724                logic error in absentee_utility_.
  725 
  726      Action:   Contact the system programming staff.
  727 
  728 
  729                [absentee_utility_.pl1]
  730                absentee_utility_:  Entry not found.  Creating new
  731                >sc1>absentee_data
  732 
  733 
  734      Stream:   as (severity1)
  735 
  736      Time:     During startup of the absentee facility.
  737 
  738      Meaning:  The  absentee data segment  was missing and  a new
  739                one has been created.
  740 
  741      Action:   Note for system programmer action.
  742 
  743 
  744                [absentee_utility_.pl1]
  745                absentee_utility_:  Entry not found.  Creating new
  746                >sc1>absentee_N.ms
  747 
  748 
  749      Stream:   as (severity1)
  750 
  751      Time:     During startup of the absentee facility.
  752 
  753      Meaning:  The  absentee  message  segment  for  queue  N was
  754                missing,  and a  new  one  has been  created.  Any
  755                previously submitted absentee jobs  in queue N are
  756                not executed.
  757 
  758      Action:   If  the  absentee  queues  never  existed  or were
  759                deliberately  deleted  or  removed,  this  message
  760                should be ignored.  Otherwise, it may be necessary
  761                to inform  users via the  message of the  day that
  762                the  absentee  requests  for  queue  N  were lost.
  763                Contact the  system programming staff for  help in
  764                recovering the queue.
  765 
  766 
  767 
  768 absentee_utility_               14            08/21/20     MR12.7^L
  769 
  770 
  771 
  772 
  773                [absentee_utility_.pl1]
  774                absentee_utility_:   ERROR_MESSAGE Dropping  queue
  775                >sc1>absentee_N.ms due to M consecutive errors
  776 
  777 
  778      Stream:   as (severity2)
  779 
  780      Time:     While system is running.
  781 
  782      Meaning:  This  message is printed  when a series  of errors
  783                prevents the  absentee facility from  reading jobs
  784                from a given queue.   Absentee requests in queue N
  785                are ignored until the absentee facility is stopped
  786                and restarted, or the command abs start queue N is
  787                used to restart the dropped queue.
  788 
  789      Action:   Note for system programmer action.
  790 
  791 
  792                [absentee_utility_.pl1]
  793                absentee_utility_:     ERROR_MESSAGE    Truncating
  794                absentee_data.
  795 
  796 
  797      Stream:   as (severity2)
  798 
  799      Time:     While system is running.
  800 
  801      Meaning:  An error  occurred during the attempt  to truncate
  802                absentee_data prior to rebuilding it.  It will not
  803                be possible to rebuild it.
  804 
  805      Action:   Contact the system programming staff.
  806 
  807 
  808                [absentee_utility_.pl1]
  809                absentee_utility_:    ERROR_MESSAGE.    Error   in
  810                creating defer event channel
  811 
  812 
  813      Stream:   as (severity2)
  814 
  815      Time:     During startup of the absentee facility.
  816 
  817      Meaning:  The  event  channel  used  in  processing absentee
  818                requests  that  are  deferred  until  a later time
  819                cannot  be  created.   No  deferred  requests  are
  820                activated.
  821 
  822      Action:   Issue  an  abs  stop  command  and  wait until all
  823                absentees run  to completion.  Then, issue  an abs
  824 
  825 
  826 absentee_utility_               15            08/21/20     MR12.7^L
  827 
  828 
  829                start  command.   If  this  same  message  recurs,
  830                contact the system programming staff.
  831 
  832 
  833 
  834                [absentee_utility_.pl1]
  835                absentee_utility_:    ERROR_MESSAGE.   Unable   to
  836                create >sc1>absentee_data
  837 
  838 
  839      Stream:   as (severity2)
  840 
  841      Time:     During startup of the absentee facility.
  842 
  843      Meaning:  The  absentee data  segment could  not be created.
  844                Faults  will   probably  occur  in   the  absentee
  845                facility  if the  system attempts  to run absentee
  846                jobs.
  847 
  848      Action:   Notify  the  system  programming  staff.   Do  _^Hn_^Ho_^Ht
  849                attempt to run absentee jobs.
  850 
  851 
  852 
  853                [absentee_utility_.pl1]
  854                absentee_utility_:    ERROR_MESSAGE.   Unable   to
  855                create >sc1>absentee_N.ms
  856 
  857 
  858      Stream:   as (severity1)
  859 
  860      Time:     During startup of the absentee facility.
  861 
  862      Meaning:  The absentee message segment for queue N cannot be
  863                created.  Users cannot queue  jobs in queue N, and
  864                jobs in queue N cannot be executed.
  865 
  866      Action:   Contact the system programming staff.
  867 
  868 
  869                [absentee_utility_.pl1]
  870                absentee_utility_:  ERROR_MESSAGE.  Unable to open
  871                new >sc1>absentee_N.ms
  872 
  873 
  874      Stream:   as (severity1)
  875 
  876      Time:     During startup of the absentee facility.
  877 
  878      Meaning:  The  absentee  message  segment  for  queue N just
  879                created  cannot be  found.  No  absentee jobs  are
  880                run.
  881 
  882 
  883 
  884 absentee_utility_               16            08/21/20     MR12.7^L
  885 
  886 
  887      Action:   Contact the system programming staff.
  888 
  889 
  890                [absentee_utility_.pl1]
  891                absentee_utility_:  ERROR_MESSAGE.   Unable to set
  892                access on >sc1>absentee_data
  893 
  894 
  895      Stream:   as (severity1)
  896 
  897      Time:     During startup of the absentee facility.
  898 
  899      Meaning:  The newly-created segment  absentee_data cannot be
  900                given correct access.   The system should continue
  901                to run.
  902 
  903      Action:   Note for system programmer action.
  904 
  905 
  906                [absentee_utility_.pl1]
  907                absentee_utility_:    ERROR_MESSAGE.   Unable   to
  908                terminate >sc1>absentee_data
  909 
  910 
  911      Stream:   as (severity1)
  912 
  913      Time:     During shutdown of the absentee facility.
  914 
  915      Meaning:  While  shutting down   the absentee  facility, the
  916                system   attempted   to   terminate   the  segment
  917                absentee_data   and  received   an  error.    This
  918                condition is not serious.
  919 
  920      Action:   Note for system programmer action.
  921 
  922 
  923                [absentee_utility_.pl1]
  924                absentee_utility_:  ERROR_MESSAGE.   Attempting to
  925                cancel reservation REQUEST for USER (ABSENTEE)
  926 
  927 
  928      Stream:   Logged in SYSERR log.
  929 
  930      Time:     While system is running.
  931 
  932      Meaning:  An   error  occurred   while  cancelling   an  RCP
  933                reservation for an absentee being deferred.
  934 
  935      Action:   No operator action is required.
  936 
  937 
  938                [absentee_utility_.pl1]
  939 
  940 
  941 
  942 absentee_utility_               17            08/21/20     MR12.7^L
  943 
  944 
  945                absentee_utility_:      ERROR_MESSAGE.     Closing
  946                >sc1>absentee_N.ms
  947 
  948 
  949      Stream:   as (severity1)
  950 
  951      Time:     While shutting down the absentee facility.
  952 
  953      Meaning:  A  storage system  error occurred  as part  of the
  954                processing  of  "abs  stop"  while  attempting  to
  955                terminate the  absentee message segment  for queue
  956                N.   Absentee requests for  queue N may  have been
  957                lost.
  958 
  959      Action:   If  you are  shutting down  the absentee  facility
  960                because  of some  previous message-segment  error,
  961                contact  the system  programming staff  and do not
  962                try  to restart  the absentee  facility.  If  this
  963                absentee  shutdown is   a normally  scheduled one,
  964                notify the  system programmers of the  message and
  965                do not try to  restart the absentee facility again
  966                until they have looked at the problem.
  967 
  968 
  969 
  970                [absentee_utility_.pl1]
  971                absentee_utility_:    ERROR_MESSAGE.     queue   N
  972                >sc1>absentee_N.ms
  973 
  974 
  975      Stream:   as (severity1)
  976 
  977      Time:     While system is running.
  978 
  979      Meaning:  An  error occurred   while reading,  rewriting, or
  980                deleting  a request from  queue N.  An  attempt is
  981                made to correct the error and retry the operation.
  982                Additional  messages are  printed if  this attempt
  983                fails.
  984 
  985      Action:   Contact the system programming staff.
  986 
  987 
  988                [absentee_utility_.pl1]
  989                absentee_utility_:     ERROR_MESSAGE.    Searching
  990                queue QUEUE skip list for USER (ABSENTEE)
  991 
  992 
  993      Stream:   Logged in SYSERR log.
  994 
  995      Time:     While system is running.
  996 
  997 
  998 
  999 
 1000 absentee_utility_               18            08/21/20     MR12.7^L
 1001 
 1002 
 1003      Meaning:  An  error occurred  while searching  the skip list
 1004                for an absentee request.
 1005 
 1006      Action:   No operator action is required.
 1007 
 1008 
 1009                [absentee_utility_.pl1]
 1010                absentee_utility_:  ERROR_MESSAGE.  Searching skip
 1011                list for USER (ABSENTEE)
 1012 
 1013 
 1014      Stream:   Logged in SYSERR log.
 1015 
 1016      Time:     While system is running.
 1017 
 1018      Meaning:  An  error occurred  while searching  the skip list
 1019                for an absentee request.
 1020 
 1021      Action:   No operator action is required.
 1022 
 1023 
 1024                [absentee_utility_.pl1]
 1025                absentee_utility_:   ERROR_MESSAGE.  Sending  TYPE
 1026                wakeup to PROCID (ABS-EVENT)
 1027 
 1028 
 1029      Stream:   Logged in SYSERR log.
 1030 
 1031      Time:     While system is running.
 1032 
 1033      Meaning:  An  error occurred  while sending  an "aum_ctl" or
 1034                "login" wakeup to the specified absentee process.
 1035 
 1036      Action:   No operator action is required.
 1037 
 1038 
 1039                [absentee_utility_.pl1]
 1040                absentee_utility_:    ERROR_MESSAGE.   Unable   to
 1041                delete request for USER (ABSENTEE); queue:  QUEUE;
 1042                index:  QUEUE_INDEX
 1043 
 1044 
 1045      Stream:   as (severity0)
 1046 
 1047      Time:     While system is running.
 1048 
 1049      Meaning:  An  error occurred  while deleting  a request from
 1050                the absentee queue.
 1051 
 1052      Action:   No operator action is required.
 1053 
 1054 
 1055                [absentee_utility_.pl1]
 1056 
 1057 
 1058 absentee_utility_               19            08/21/20     MR12.7^L
 1059 
 1060 
 1061                absentee_utility_:    ERROR_MESSAGE.   Unable   to
 1062                notify user USER of absentee event.
 1063 
 1064 
 1065      Stream:   Logged in SYSERR log.
 1066 
 1067      Time:     While system is running.
 1068 
 1069      Meaning:  An error occurred while  sending a message to USER
 1070                as notification of an absentee event.
 1071 
 1072 
 1073 
 1074                [absentee_utility_.pl1]
 1075                absentee_utility_:  ERROR_MESSAGE.   Unable to set
 1076                extended access on >sc1>absentee_N.ms
 1077 
 1078 
 1079      Stream:   as (severity1)
 1080 
 1081      Time:     During startup of the absentee facility.
 1082 
 1083      Meaning:  The  absentee  message  segment  for  queue N just
 1084                created cannot be set up  so that users can access
 1085                it  properly.  Users  will not  be able  to submit
 1086                absentee requests.
 1087 
 1088      Action:   Contact the system programming staff.
 1089 
 1090 
 1091                [absentee_utility_.pl1]
 1092                absentee_utility_:  ERROR_MESSAGE.   While reading
 1093                message  MESSAGE   from  USER  (ABSENTEE)   to  be
 1094                rewritten.
 1095 
 1096 
 1097      Stream:   Logged in SYSERR log.
 1098 
 1099      Time:     While system is running.
 1100 
 1101      Meaning:  An error occurred while reading a request from the
 1102                absentee queue.
 1103 
 1104      Action:   No operator action is required.
 1105 
 1106 
 1107                [absentee_utility_.pl1]
 1108                absentee_utility_:  ERROR_MESSAGE.   While reading
 1109                message MESSAGE to be rewritten.
 1110 
 1111 
 1112      Stream:   Logged in SYSERR log.
 1113 
 1114 
 1115 
 1116 absentee_utility_               20            08/21/20     MR12.7^L
 1117 
 1118 
 1119      Time:     While system is running.
 1120 
 1121      Meaning:  An  error  occurred   while  reading  an  absentee
 1122                request to be marked as "running".
 1123 
 1124      Action:   No operator action is required.
 1125 
 1126 
 1127                [absentee_utility_.pl1]
 1128                absentee_utility_:   Illegal  proxy  for NAME.PROJ
 1129                from NAME1.PROJ1 for job JJJJ
 1130 
 1131 
 1132      Stream:   as (severity1)
 1133 
 1134      Time:     While system is running.
 1135 
 1136      Meaning:  This message is printed  whenever a proxy absentee
 1137                job is  submitted by some user who  is not allowed
 1138                to submit a proxy.  User NAME1.PROJ1 submitted job
 1139                JJJJ to be run with the user ID NAME.PROJ, but the
 1140                absentee facility  will not do so  and ignores the
 1141                request.
 1142 
 1143      Action:   Note for system programmer action.
 1144 
 1145 
 1146                [absentee_utility_.pl1]
 1147                absentee_utility_:   Illegal queue  number (QUEUE)
 1148                for USER (ABSENTEE)
 1149 
 1150 
 1151      Stream:   as (severity0)
 1152 
 1153      Time:     While system is running.
 1154 
 1155      Meaning:  The queue number specified for the absentee job in
 1156                the absentee user table has an illegal value.
 1157 
 1158      Action:   No operator action is required.
 1159 
 1160 
 1161                [absentee_utility_.pl1]
 1162                absentee_utility_:   Loop in PROC,  searching NAME
 1163                list for queue N.
 1164 
 1165 
 1166      Stream:   as (severity1)
 1167 
 1168      Time:     While system is running.
 1169 
 1170      Meaning:  A software error has  damaged the list of requests
 1171                in absentee_data.   The error was detected  by the
 1172 
 1173 
 1174 absentee_utility_               21            08/21/20     MR12.7^L
 1175 
 1176 
 1177                internal procedure, PROC, while searching the NAME
 1178                list belonging  to queue N.  The  system makes one
 1179                attempt to rebuild  the list.  Additional messages
 1180                are printed if this attempt fails.
 1181 
 1182      Action:   Contact the system programming staff.
 1183 
 1184 
 1185                [absentee_utility_.pl1]
 1186                absentee_utility_:  Loop occurred while rebuilding
 1187                absentee_data after previous loop.
 1188 
 1189 
 1190      Stream:   as (severity2)
 1191 
 1192      Time:     While system is running.
 1193 
 1194      Meaning:  The  error   reported  by  the   previous  message
 1195                occurred  while  absentee_data  was  being rebuilt
 1196                following an  earlier error.  The  rebuild attempt
 1197                will not be repeated.
 1198 
 1199      Action:   Contact the system programming staff.
 1200 
 1201 
 1202                [absentee_utility_.pl1]
 1203                absentee_utility_:  rejected request  ID (PATH) in
 1204                queue N from PERS.PROJ:  REASON
 1205 
 1206 
 1207      Stream:   as (severity1)
 1208 
 1209      Time:     While system is running.
 1210 
 1211      Meaning:  This message is printed  if a message that appears
 1212                to be garbled or  meaningless is found in absentee
 1213                queue  N.  The  garbled message  is ignored.  This
 1214                condition  may be  evidence of  damage to absentee
 1215                queue N, unless REASON indicates otherwise.
 1216 
 1217      Action:   Note for system programmer action.
 1218 
 1219 
 1220                [absentee_utility_.pl1]
 1221                absentee_utility_:   Timer  rang  and  no deferred
 1222                request found.
 1223 
 1224 
 1225      Stream:   as (severity0)
 1226 
 1227      Time:     While system is running.
 1228 
 1229 
 1230 
 1231 
 1232 absentee_utility_               22            08/21/20     MR12.7^L
 1233 
 1234 
 1235      Meaning:  The  deferred  request  timer   went  off  and  no
 1236                deferred absentee jobs were found.
 1237 
 1238      Action:   No operator action is required.
 1239 
 1240 
 1241                [accept_fs_disk.pl1]
 1242                accept_fs_disk:   part NAME  on PVNAME  (dskX_NNS)
 1243                from AAA for BBB overlaps pages from CCC
 1244 
 1245 
 1246      Stream:   BOS Typewriter.
 1247 
 1248      Time:     When accepting a disk volume.
 1249 
 1250      Meaning:  The  supervisor checks  the partitions  defined in
 1251                the  volume  label  against  the  beginning of the
 1252                paging  partition when  it accepts  a volume.  The
 1253                partition  NAME  overlaps  the  paging  area.  The
 1254                volume label may have been damaged.
 1255 
 1256      Action:   Be  careful not  to destroy  the contents  of part
 1257                NAME, since this will destory the contents of user
 1258                segments.  Note for system programmer action.
 1259 
 1260 
 1261 
 1262                [accept_rpv.pl1]
 1263                accept_rpv:  Error ERRORMESSAGE accepting RPV
 1264 
 1265 
 1266      Stream:   BOS Typewriter (Crashes system)
 1267 
 1268      Time:     System Intialization.
 1269 
 1270      Meaning:  Some problem was encountered  trying to set up the
 1271                use  of the  RPV for  normal segment  creation and
 1272                activation.   The label of  the RPV may  have been
 1273                damaged, or encountered  disk errors, as indicated
 1274                by the ERRORMESSAGE.
 1275 
 1276      Action:   Make  sure that  the RPV  label area  (first eight
 1277                records), or a dump of it, is available for system
 1278                programmer inspection.  Note for system programmer
 1279                action.
 1280 
 1281                Message:  accept_rpv:  HC part on dskX_NN used XXX
 1282                out of YYY records.
 1283 
 1284      Stream:   This message is printed on  the console if an HCPT
 1285                card  is in  the  config  deck.  Otherwise,  it is
 1286                logged into the syserr_log.
 1287 
 1288 
 1289 
 1290 accept_rpv                      23            08/21/20     MR12.7^L
 1291 
 1292 
 1293      Time:     System Intialization.
 1294 
 1295      Meaning:  The  message appears  for each  disk volume  which
 1296                contains  a  Hardcore  Partition  (PART  HC).   It
 1297                indicates  how  many  records  were  actually used
 1298                (XXX) in the partition, which had size YYY.
 1299 
 1300      Action:   No operator action is required.
 1301 
 1302 
 1303                [accept_rpv.pl1]
 1304                accept_rpv:  pv PVNAME lv  LVNAME (DSKX_NN) is not
 1305                part of root.
 1306 
 1307 
 1308      Stream:   BOS Typewriter (Crashes system)
 1309 
 1310      Time:     System Intialization.
 1311 
 1312      Meaning:  The pack on the drive DSKX_NN, with pv name and lv
 1313                name as  read from its label, is  specified on the
 1314                ROOT  CONFIG card,  but is  not part  of the  same
 1315                logical volume as the RPV.
 1316 
 1317      Action:   Check the ROOT CONFIG  card for errors.  Check for
 1318                the proper packs.  Reboot the system.
 1319 
 1320 
 1321 
 1322                [access_audit_.pl1]
 1323                access_audit_$ENTRY:    (USER_ID)    Called   with
 1324                insufficient      arguments     (#args=      ^d).(
 1325                Caller=""CALLING_PROC".)
 1326 
 1327 
 1328      Stream:   BOS Typewriter.
 1329 
 1330      Time:     While system is running.
 1331 
 1332      Meaning:  This indicates a logic error in the supervisor, or
 1333                CPU  or memory  hardware problems.   access_audit_
 1334                was  invoked with   an improper  calling sequence.
 1335                There  may have  been enough  arguments to display
 1336                the offending caller name.
 1337 
 1338      Action:   Contact the system programming staff.
 1339 
 1340 
 1341                [access_audit_.pl1]
 1342                access_audit_$ENTRY:      (USER_ID)    Encountered
 1343                illegal   meter    index.    OperCode=XXXXXXXXXXXX
 1344                EventFlags=YYYYYYYYYYYY.( Caller="CALLING_PROC".)
 1345 
 1346 
 1347 
 1348 access_audit_$ENTRY             24            08/21/20     MR12.7^L
 1349 
 1350 
 1351      Stream:   Logged in SYSERR log.
 1352 
 1353      Time:     While system is running.
 1354 
 1355      Meaning:  This indicates a logic error in the supervisor, or
 1356                CPU or memory hardware problems.  The access audit
 1357                meters  in  active_hardcore_data  are inconsistant
 1358                with the format of the process access flags or the
 1359                supplied operation code and/or event flags.
 1360 
 1361      Action:   Contact the system programming staff.
 1362 
 1363 
 1364                [access_audit_.pl1]
 1365                access_audit_$ENTRY:      (USER_ID)    Encountered
 1366                illegal           parameter           combination.
 1367                OperCode=XXXXXXXXXXXX    EventFlags=YYYYYYYYYYYY.(
 1368                Caller="CALLING_PROC".)
 1369 
 1370 
 1371      Stream:   BOS Typewriter.
 1372 
 1373      Time:     While system is running.
 1374 
 1375      Meaning:  This indicates a logic error in the supervisor, or
 1376                CPU  or  memory  hardware  problems.   There is an
 1377                error  in  the  access_operations_  entry  or  the
 1378                eventflags passed to access  audit.  The error was
 1379                detected  in the  code which  decides whether  the
 1380                caller needs  to audit its event.   Because of the
 1381                error, the event will be audited regardless of the
 1382                process audit flags.
 1383 
 1384      Action:   Contact the system programming staff.
 1385 
 1386 
 1387                [access_audit_.pl1]
 1388                access_audit_$ENTRY:   (USER_ID) Improper  calling
 1389                sequence   (from   "get_entry_pointer_and_class").
 1390                Caller="CALLING_PROC".
 1391 
 1392 
 1393      Stream:   BOS Typewriter.
 1394 
 1395      Time:     While system is running.
 1396 
 1397      Meaning:  This indicates a logic error in the supervisor, or
 1398                CPU  or memory  hardware problems.   The entry was
 1399                called  with  an  improper  argument  combination.
 1400                Most    likely   the     entry   will    be   (log
 1401                check)_obj_ptr_(user)  and  the  obj_ptr  supplied
 1402                will be null.
 1403 
 1404 
 1405 
 1406 access_audit_$ENTRY             25            08/21/20     MR12.7^L
 1407 
 1408 
 1409      Action:   Contact the system programming staff.
 1410 
 1411 
 1412                [access_audit_.pl1]
 1413                access_audit_$ENTRY:  (USER_ID) Unable to generate
 1414                path   for  entry   at  PTR   due  to   "MESSAGE".
 1415                Caller="CALLING_PROC".
 1416 
 1417 
 1418      Stream:   Logged in SYSERR log.
 1419 
 1420      Time:     While system is running.
 1421 
 1422      Meaning:  This indicates a logic error in the supervisor, or
 1423                CPU  or  memory  hardware  problems.   A  call  to
 1424                get_pathname_ returned an unexpected error code.
 1425 
 1426      Action:   Contact the system programming staff.
 1427 
 1428 
 1429                [access_audit_.pl1]
 1430                access_audit_$ENTRY:   (USER_ID)   Unable  to  get
 1431                entry  pointer   for  seg  [#N  |   PATH]  due  to
 1432                "MESSAGE".
 1433 
 1434 
 1435      Stream:   Logged in SYSERR log.
 1436 
 1437      Time:     While system is running.
 1438 
 1439      Meaning:  This indicates a logic error in the supervisor, or
 1440                CPU  or  memory  hardware  problems.   A  call  to
 1441                sum$getbranch_root_my   or   dc_find$obj_for_audit
 1442                returned an unexpected error code.
 1443 
 1444      Action:   Contact the system programming staff.
 1445 
 1446 
 1447                [access_audit_.pl1]
 1448                access_audit_$ENTRY:  (USER_ID) Unable  to get raw
 1449                access  modes  for  entry  PTR  due  to "MESSAGE".
 1450                Caller="CALLER_PROC".
 1451 
 1452 
 1453      Stream:   Logged in SYSERR log.
 1454 
 1455      Time:     While system is running.
 1456 
 1457      Meaning:  This indicates a logic error in the supervisor, or
 1458                CPU  or memory   hardware problems.   Although the
 1459                directory   is  locked   a  failure   occurred  in
 1460                access_mode$raw.
 1461 
 1462 
 1463 
 1464 access_audit_$ENTRY             26            08/21/20     MR12.7^L
 1465 
 1466 
 1467      Action:   Contact the system programming staff.
 1468 
 1469 
 1470                [access_audit_.pl1]
 1471                access_audit_$ENTRY:  (USER_ID) Unable  to get UID
 1472                path  for  directory  seg  #N  due  to  "MESSAGE".
 1473                Caller="CALLER_PROC".
 1474 
 1475 
 1476      Stream:   Logged in SYSERR log.
 1477 
 1478      Time:     While system is running.
 1479 
 1480      Meaning:  This indicates a logic error in the supervisor, or
 1481                CPU  or memory   hardware problems.   Although the
 1482                directory  is   locked,  a  failure   occurred  in
 1483                uid_path_util$get.
 1484 
 1485      Action:   Contact the system programming staff.
 1486 
 1487 
 1488                [access_audit_.pl1]
 1489                access_audit_$ENTRY:   (USER_ID) Unexpected  error
 1490                obtaining        caller       text        pointer.
 1491                Caller="CALLING_PROC".
 1492 
 1493 
 1494      Stream:   BOS Typewriter.
 1495 
 1496      Time:     While system is running.
 1497 
 1498      Meaning:  This indicates a logic error in the supervisor, or
 1499                CPU or memory hardware  problems.  An error exists
 1500                in the calling sequence to access_audit_.
 1501 
 1502      Action:   Contact the system programming staff.
 1503 
 1504 
 1505                [access_audit_.pl1]
 1506                access_audit_$UNKNOWN:       (USER_ID)     Illegal
 1507                entrypoint      index     "N"      detected     in
 1508                form_audit_message_text.  Caller="CALLING_PROC".
 1509 
 1510 
 1511      Stream:   BOS Typewriter.
 1512 
 1513      Time:     While system is running.
 1514 
 1515      Meaning:  This indicates a logic error in the supervisor, or
 1516                CPU  or  memory  hardware  problems.   There  is a
 1517                coding error in access_audit_ where the entrypoint
 1518                index  is  uninitialized  or  set  to an incorrect
 1519                value.
 1520 
 1521 
 1522 access_audit_$UNKNOWN           27            08/21/20     MR12.7^L
 1523 
 1524 
 1525      Action:   Contact the system programming staff.
 1526 
 1527 
 1528                [access_audit_.pl1]
 1529                access_audit_:   Insufficient   room  to  allocate
 1530                [ssobj|link] data.
 1531 
 1532 
 1533      Stream:   BOS Typewriter.
 1534 
 1535      Time:     While system is running.
 1536 
 1537      Meaning:  This indicates a logic error in the supervisor, or
 1538                CPU  or memory   hardware problems.   An automatic
 1539                data area  is too small to  accomodate the storage
 1540                system object or link binary info.
 1541 
 1542      Action:   Contact the system programming staff.
 1543 
 1544 
 1545                [access_audit_log_fault_.pl1]
 1546                access_audit_log_fault_:   (USER_ID Unable  to get
 1547                path of seg #N due to "MESSAGE".
 1548 
 1549 
 1550      Stream:   BOS Typewriter.
 1551 
 1552      Time:     While system is running.
 1553 
 1554      Meaning:  This indicates a logic error in the supervisor, or
 1555                CPU  or  memory  hardware  problems.   A  call  to
 1556                get_pathname_ returned an unexpected error code.
 1557 
 1558      Action:   Contact the system programming staff.
 1559 
 1560 
 1561                [access_audit_log_fault_.pl1]
 1562                access_audit_log_fault_:   (USER_ID)  Called  with
 1563                bad machine conditions.
 1564 
 1565 
 1566      Stream:   BOS Typewriter.
 1567 
 1568      Time:     While system is running.
 1569 
 1570      Meaning:  This indicates a logic error in the supervisor, or
 1571                CPU      or     memory      hardware     problems.
 1572                access_audit_log_fault_    was    given    machine
 1573                conditions  for  a  fault  which  was  neither  an
 1574                illegal_procedure or an access_violation.
 1575 
 1576      Action:   Contact the system programming staff.
 1577 
 1578 
 1579 
 1580 access_audit_log_fault_         28            08/21/20     MR12.7^L
 1581 
 1582 
 1583 
 1584 
 1585                [access_audit_log_fault_.pl1]
 1586                access_audit_log_fault_:    (USER_ID)  Encountered
 1587                illegal meter index value.
 1588 
 1589 
 1590      Stream:   BOS Typewriter.
 1591 
 1592      Time:     While system is running.
 1593 
 1594      Meaning:  This indicates a logic error in the supervisor, or
 1595                CPU or memory hardware problems.  The access audit
 1596                meters  in  active_hardcore_data  are inconsistant
 1597                with the format of the process access flags.
 1598 
 1599      Action:   Contact the system programming staff.
 1600 
 1601 
 1602                [access_audit_log_fault_.pl1]
 1603                access_audit_log_fault_:  (USER_ID)  Unable to get
 1604                access mode for data seg #N due to "MESSAGE".
 1605 
 1606 
 1607      Stream:   BOS Typewriter.
 1608 
 1609      Time:     While system is running.
 1610 
 1611      Meaning:  This indicates a logic error in the supervisor, or
 1612                CPU  or  memory  hardware  problems.   A  call  to
 1613                fs_modes  failed unexpectedly.  The  AUDIT message
 1614                text  will  show  the  modes  as  "???"   and ring
 1615                brackets  of  7,7,7.    The  message  binary  will
 1616                reflect  null  access  mode  and  ring  bracket of
 1617                7,7,7.
 1618 
 1619      Action:   Contact the system programming staff.
 1620 
 1621 
 1622                [access_audit_log_fault_.pl1]
 1623                access_audit_log_fault_:  (USER_ID)  Unable to get
 1624                entry pointer for seg #N due to "MESSAGE".
 1625 
 1626 
 1627      Stream:   BOS Typewriter.
 1628 
 1629      Time:     While system is running.
 1630 
 1631      Meaning:  This indicates a logic error in the supervisor, or
 1632                CPU  or  memory  hardware  problems.   A  call  to
 1633                sum$getbranch_root_my returned an unexpected error
 1634                code.
 1635 
 1636 
 1637 
 1638 access_audit_log_fault_         29            08/21/20     MR12.7^L
 1639 
 1640 
 1641      Action:   Contact the system programming staff.
 1642 
 1643 
 1644                [access_audit_log_fault_.pl1]
 1645                access_audit_log_fault_:  (USER_ID)  Unable to get
 1646                raw access modes for entry PTR due to "MESSAGE".
 1647 
 1648 
 1649      Stream:   BOS Typewriter.
 1650 
 1651      Time:     While system is running.
 1652 
 1653      Meaning:  This indicates a logic error in the supervisor, or
 1654                CPU  or memory   hardware problems.   Although the
 1655                directory   is  locked   a  failure   occurred  in
 1656                access_mode$raw.
 1657 
 1658      Action:   Contact the system programming staff.
 1659 
 1660 
 1661                [access_audit_log_fault_.pl1]
 1662                access_audit_log_fault_:  (USER_ID)  Unable to get
 1663                UID path for directory seg #N due to "MESSAGE".
 1664 
 1665 
 1666      Stream:   BOS Typewriter.
 1667 
 1668      Time:     While system is running.
 1669 
 1670      Meaning:  This indicates a logic error in the supervisor, or
 1671                CPU  or memory   hardware problems.   Although the
 1672                directory  is   locked,  a  failure   occurred  in
 1673                uid_path_util$get.
 1674 
 1675      Action:   Contact the system programming staff.
 1676 
 1677 
 1678                [access_audit_log_fault_.pl1]
 1679                access_audit_log_fault_:  Link  entry where branch
 1680                expected (ep=PTR).
 1681 
 1682 
 1683      Stream:   BOS Typewriter (Crashes system)
 1684 
 1685      Time:     While system is running.
 1686 
 1687      Meaning:  This indicates a logic error in the supervisor, or
 1688                CPU or memory hardware  problems.  After getting a
 1689                directory  entry for  a specific  segno the branch
 1690                switch in the entry was found to be off.
 1691 
 1692      Action:   Follow normal recovery procedures.
 1693 
 1694 
 1695 
 1696 access_viol                     30            08/21/20     MR12.7^L
 1697 
 1698 
 1699 
 1700 
 1701                [access_viol.pl1]
 1702                access_viol:  associative memory fault.
 1703 
 1704 
 1705      Stream:   BOS Typewriter (Crashes system)
 1706 
 1707      Time:     While system is running.
 1708 
 1709      Meaning:  The  processor associative  memory has  detected a
 1710                usage count error.
 1711 
 1712      Action:   Notify Field Engineering personnel.
 1713 
 1714 
 1715                [act_ctl_.pl1]
 1716                act_ctl_$dp:    Net   accounting   array   version
 1717                (VERSION_RETURNED)   not    supported.    Expected
 1718                version (VERSION_SUPPORTED)
 1719 
 1720 
 1721 
 1722      Stream:   as (severity2).
 1723 
 1724      Time:     While system is running.
 1725 
 1726      Meaning:  network_accounting_gate_$read_and_reset_table
 1727                returned a  structure version which  act_ctl_ does
 1728                not  support.This indicates  a logic  error in the
 1729                supervisor, or CPU or memory hardware problems.
 1730 
 1731      Action:   Contact the system programming staff._sm
 1732 
 1733 
 1734                [act_ctl_.pl1]
 1735                act_ctl_$init:             cannot           locate
 1736                Initializer.SysDaemon pdt entry
 1737 
 1738 
 1739      Stream:   as (severity2)
 1740 
 1741      Time:     System Intialization.
 1742 
 1743      Meaning:  The  accounting  system  requires  the  entry  for
 1744                Initializer in the project SysDaemon to be present
 1745                because certain  system metering figures  are kept
 1746                there.  This entry cannot be found, either because
 1747                SysDaemon.pdt  has  been   lost,  or  because  its
 1748                contents  have been   destroyed.  The  system will
 1749                probably  encounter a   simfault_xxx error  and be
 1750                unable to start up.
 1751 
 1752 
 1753 
 1754 act_ctl_$init                   31            08/21/20     MR12.7^L
 1755 
 1756 
 1757      Action:   Contact  the  system  programming  staff.   Do not
 1758                attempt to  run the system until  this problem has
 1759                been fixed.
 1760 
 1761 
 1762 
 1763                [act_ctl_.pl1]
 1764                act_ctl_$init:  ERROR_MESSAGE.   Cannot unlock PDT
 1765                PATHNAME.
 1766 
 1767 
 1768      Stream:   as (severity2)
 1769 
 1770      Time:     System Intialization.
 1771 
 1772      Meaning:  This  message  occurs   during  answering  service
 1773                initialization when attempting to unlock all PDTs.
 1774                ERROR_MESSAGE  specifies the   the reason  for the
 1775                problem.  The PDT is  skipped.  Later problems may
 1776                arise because of this error.
 1777 
 1778      Action:   Contact the system programming staff.
 1779 
 1780 
 1781                [act_ctl_.pl1]
 1782                act_ctl_$init:   ERROR_MESSAGE.   creating  update
 1783                channel
 1784 
 1785 
 1786      Stream:   as (severity2)
 1787 
 1788      Time:     System Intialization.
 1789 
 1790      Meaning:  The timer  channel that causes  accounting updates
 1791                to  be  performed  could   not  be  created.   All
 1792                accounting updates will be  manual, triggered by a
 1793                user logging out.
 1794 
 1795      Action:   Contact the system programming staff.
 1796 
 1797 
 1798                [act_ctl_.pl1]
 1799                act_ctl_$init:  illegal value  (DD) for accounting
 1800                update interval in installation_parms.
 1801 
 1802 
 1803      Stream:   as (severity2)
 1804 
 1805      Time:     System Intialization.
 1806 
 1807      Meaning:  The value  given in installation_parms.acct_update
 1808                is   less   than   or    equal   to   zero.    The
 1809                installation_parms file is probabily damaged.
 1810 
 1811 
 1812 act_ctl_$init                   32            08/21/20     MR12.7^L
 1813 
 1814 
 1815      Action:   Contact  the  system  programming  staff.   Do not
 1816                attempt to  run the system until  this problem has
 1817                been fixed.
 1818 
 1819 
 1820 
 1821                [act_ctl_.pl1]
 1822                act_ctl_$init:  The PDT is damaged.  Cannot unlock
 1823                PATHNAME.
 1824 
 1825 
 1826      Stream:   as (severity2)
 1827 
 1828      Time:     System Intialization.
 1829 
 1830      Meaning:  This  message  occurs   during  answering  service
 1831                initialization when attempting to unlock all PDTs.
 1832                The  specified PDT  had its  damaged switch turned
 1833                on.  Because of this, it was not unlocked from the
 1834                previous bootload.  It is skipped.  Later problems
 1835                may  arise when  an attempt  is made  to reference
 1836                this PDT.
 1837 
 1838      Action:   Contact the system programming staff.
 1839 
 1840 
 1841                [act_ctl_.pl1]
 1842                act_ctl_$update:  Error from ROUTINE:  MESSAGE
 1843 
 1844 
 1845      Stream:   as (severity2).
 1846 
 1847      Time:     While system is running.
 1848 
 1849      Meaning:  The system encountered  problems while referencing
 1850                the         network_accounting_table.          The
 1851                network_accounting_   ROUTINE  being   called  and
 1852                MESSAGE text further describe the error.
 1853 
 1854      Action:   Contact the system programming staff.
 1855 
 1856 
 1857                [act_ctl_.pl1]
 1858                act_ctl_$update:   Net  accounting  array  version
 1859                (VERSION_RETURNED)   not    supported.    Expected
 1860                version (VERSION_SUPPORTED)
 1861 
 1862 
 1863 
 1864      Stream:   as (severity2).
 1865 
 1866      Time:     While system is running.
 1867 
 1868 
 1869 
 1870 act_ctl_$update                 33            08/21/20     MR12.7^L
 1871 
 1872 
 1873      Meaning:  network_accounting_gate_$read_and_reset_table
 1874                returned a  structure version which  act_ctl_ does
 1875                not  support.This indicates  a logic  error in the
 1876                supervisor, or CPU or memory hardware problems.
 1877 
 1878      Action:   Contact the system programming staff._sm
 1879 
 1880 
 1881                [act_ctl_.pl1]
 1882                act_ctl_$update:  Processid XXXXXXXX missing.  Not
 1883                charged  for  XX  pkt,  YY  byte  and  ZZ seconds;
 1884                was/was not purged.
 1885 
 1886 
 1887 
 1888      Stream:   as (severity2)
 1889 
 1890      Time:     While system is running.
 1891 
 1892      Meaning:  After  charging network  accounting usage  for all
 1893                users  on  the  system,  an  entry  was  found for
 1894                processid XXXXXXXX.  The XX,  YY and ZZ are counts
 1895                of the usage which the  process had.  If the entry
 1896                was for  a process which  is no longer  logged in,
 1897                the accounting record was  purged from the network
 1898                accounting file.
 1899 
 1900      Action:   Note for system programmer action.
 1901 
 1902 
 1903                [act_ctl_.pl1]
 1904                act_ctl_:  accounting disabled
 1905 
 1906 
 1907      Stream:   as (severity1)
 1908 
 1909      Time:     May occur at any time.
 1910 
 1911      Meaning:  The accounting system has  been disabled by a call
 1912                to act_ctl_$act_ctl_disable.
 1913 
 1914      Action:   No operator action is required.
 1915 
 1916 
 1917                [act_ctl_.pl1]
 1918                act_ctl_:  accounting enabled.
 1919 
 1920 
 1921      Stream:   as (severity1)
 1922 
 1923      Time:     May occur at any time.
 1924 
 1925 
 1926 
 1927 
 1928 act_ctl_                        34            08/21/20     MR12.7^L
 1929 
 1930 
 1931      Meaning:  The accounting  system has been  enabled, probably
 1932                after   a   special   session,   by   a   call  to
 1933                act_ctl_$act_ctl_reable.
 1934 
 1935      Action:   No operator action is required.
 1936 
 1937 
 1938                [act_ctl_.pl1]
 1939                act_ctl_:   alarm clock  late or  failing by XX.XX
 1940                mins
 1941 
 1942 
 1943      Stream:   as (severity1)
 1944 
 1945      Time:     While system is running.
 1946 
 1947      Meaning:  The  alarm   clock  channel  has  not   caused  an
 1948                accounting update to be performed when it was due.
 1949                (The time between updates is stored in the segment
 1950                installation_parms.)  The system performs a manual
 1951                accounting update.  This message may appear if the
 1952                system has entered BOS,  and Multics has then been
 1953                restarted  by the GO  command.  In such  case, the
 1954                message can be ignored.
 1955 
 1956      Action:   Note for system programmer action.
 1957 
 1958 
 1959                [act_ctl_.pl1]
 1960                act_ctl_:  bumping absNN  NAME.PROJ - inactive too
 1961                long
 1962 
 1963 
 1964      Stream:   as (severity1)
 1965 
 1966      Time:     While system is running.
 1967 
 1968      Meaning:  The  absentee job  on  absentee  slot NN  for user
 1969                NAME.PROJ  has remained   blocked too  long.  (The
 1970                inactive  time  limit  is  stored  in  the segment
 1971                installation_parms.)  The absentee job is bumped.
 1972 
 1973      Action:   No operator action is required.
 1974 
 1975 
 1976                [act_ctl_.pl1]
 1977                act_ctl_:  bumping absXX NAME.PROJ - too much time
 1978 
 1979 
 1980      Stream:   as (severity1)
 1981 
 1982      Time:     While system is running.
 1983 
 1984 
 1985 
 1986 act_ctl_                        35            08/21/20     MR12.7^L
 1987 
 1988 
 1989      Meaning:  The absentee job on absentee  slot XX for the user
 1990                NAME.PROJ has exceeded the  CPU time limit for the
 1991                queue.   (This  limit  is  stored  in  the segment
 1992                installation_parms.)  The absentee job is bumped.
 1993 
 1994      Action:   No operator action is required.
 1995 
 1996 
 1997                [act_ctl_.pl1]
 1998                act_ctl_:  bumping NAME.PROJ for inactivity
 1999 
 2000 
 2001      Stream:   as (severity1)
 2002 
 2003      Time:     While system is running.
 2004 
 2005      Meaning:  The user with name NAME  and project PROJ has been
 2006                inactive too  long, and is bumped  off the system.
 2007                The maximum inactive time is stored in the segment
 2008                installation_parms.
 2009 
 2010      Action:   No operator action is required.
 2011 
 2012 
 2013                [act_ctl_.pl1]
 2014                act_ctl_:  bumping NAME.PROJ.  REASON
 2015 
 2016 
 2017      Stream:   as (severity1)
 2018 
 2019      Time:     While system is running.
 2020 
 2021      Meaning:  The user with name NAME  and project PROJ has been
 2022                bumped  because  some   per-user  limit  has  been
 2023                exceeded.  REASON tells what was wrong; it will be
 2024                a  message such  as "User  resource limit  of $100
 2025                monthly exceeded,"  depending on which  user limit
 2026                has been exceeded.
 2027 
 2028      Action:   No operator action is required.
 2029 
 2030 
 2031                [act_ctl_.pl1]
 2032                act_ctl_:  changing shift from x to y
 2033 
 2034 
 2035      Stream:   as (severity1)
 2036 
 2037      Time:     While system is running.
 2038 
 2039      Meaning:  The  current accounting   shift has  changed.  The
 2040                table that tells the beginning time for each shift
 2041                is stored in the segment installation_parms.
 2042 
 2043 
 2044 act_ctl_                        36            08/21/20     MR12.7^L
 2045 
 2046 
 2047      Action:   No operator action is required.
 2048 
 2049 
 2050                [act_ctl_.pl1]
 2051                act_ctl_:  charged X, available Y mins
 2052 
 2053 
 2054      Stream:   as (severity0)
 2055 
 2056      Time:     While system is running.
 2057 
 2058      Meaning:  X is  the sum of  virtual CPU time  charged to all
 2059                processes and Y is the total virtual CPU time used
 2060                by  all  processes.   This  message  logs detailed
 2061                accounting  information and  appears whenever  the
 2062                message  "act_ctl_:   discrepancy  of  XX.XX mins"
 2063                appears.
 2064 
 2065      Action:   No operator action is required.
 2066 
 2067 
 2068                [act_ctl_.pl1]
 2069                act_ctl_:  discrepancy of XX.XX mins
 2070 
 2071 
 2072      Stream:   as (severity1)
 2073 
 2074      Time:     While system is running.
 2075 
 2076      Meaning:  The total time available from traffic control does
 2077                not  agree with  the total  time charged  to users
 2078                plus  the  Initializer  time  plus  the idle time.
 2079                Some process has escaped being accounted for.
 2080 
 2081      Action:   Contact the system programming staff._sa
 2082 
 2083 
 2084                [act_ctl_.pl1]
 2085                act_ctl_:    Lock  wait   time  exceeded.    While
 2086                destroying proc for NAME.PROJ
 2087 
 2088 
 2089      Stream:   as (severity2)
 2090 
 2091      Time:     While system is running.
 2092 
 2093      Meaning:  The accounting  system was unable to  lock the PDT
 2094                entry for the user NAME in the project PROJ within
 2095                its  time limit  (usually five  minutes) This user
 2096                attempted  to log out  or destroy a  process.  The
 2097                entry  was   probably  locked  because   a  system
 2098                administrator or  daemon process locked  the entry
 2099                and then failed.  The system attempts to continue.
 2100 
 2101 
 2102 act_ctl_                        37            08/21/20     MR12.7^L
 2103 
 2104 
 2105      Action:   Contact the system programming staff._sa
 2106 
 2107 
 2108                [act_ctl_.pl1]
 2109                act_ctl_:   MODE  update:    users  =  NN,  pf=XX,
 2110                vcpu=YY.Y, rt=ZZ.Z MESSAGE
 2111 
 2112 
 2113      Stream:   as (severity1)
 2114 
 2115      Time:     While system is running.
 2116 
 2117      Meaning:  Periodically,  the  accounting  programs  read and
 2118                store the  CPU usage for each  user.  This message
 2119                is printed when the update completes.  MODE may be
 2120                'Automatic', in which case  the update occurred at
 2121                the normal system  parameter time; 'Manual', where
 2122                the  normal update  didn't occur;  or 'Shift Cmnd'
 2123                where the update occurred  due to a shift command.
 2124                XX  is   the  number  of  page   faults  taken  by
 2125                Initializer for  update.  YY.Y is the  virtual CPU
 2126                time taken by Initializer for update.  ZZ.Z is the
 2127                real  time   taken  by  Initializer   for  update.
 2128                MESSAGE  may  be  one  or  both  of  the following
 2129                strings:   'answer  table  locked'  or 'install(s)
 2130                pending'
 2131 
 2132      Action:   No  operator action  is required.   The number  of
 2133                seconds  between accounting   updates is  a system
 2134                parameter that  an installation may change;  it is
 2135                stored in the segment installation_parms.
 2136 
 2137 
 2138 
 2139                [act_ctl_.pl1]
 2140                act_ctl_:   process   XXXXXXXXXXXX  for  NAME.PROJ
 2141                vanished
 2142 
 2143 
 2144      Stream:   as (severity2)
 2145 
 2146      Time:     While system is running.
 2147 
 2148      Meaning:  Traffic control cannot locate a process for a user
 2149                who should have one  according to accounting.  The
 2150                system attempts to run  normally, but this user is
 2151                not charged.  An attempt is  made to bump the user
 2152                in  question.  This  may be  the first  indication
 2153                that  the  segment  >system_control_1>answer_table
 2154                has been damaged.
 2155 
 2156      Action:   Note for system programmer action.
 2157 
 2158 
 2159 
 2160 act_ctl_                        38            08/21/20     MR12.7^L
 2161 
 2162 
 2163 
 2164 
 2165                [act_ctl_.pl1]
 2166                act_ctl_:  shutdown,  NNN WW.WW XX.XX  YY.YY ZZ.ZZ
 2167                HH:MM:SS $DDD.DD
 2168 
 2169 
 2170      Stream:   as (severity1)
 2171 
 2172      Time:     System shutdown.
 2173 
 2174      Meaning:  A successful shutdown of the accounting portion of
 2175                the system has been accomplished.  NNN logins were
 2176                recorded,  for a  total usage  of HH:MM:SS  of CPU
 2177                time charged.   The other numbers are  of interest
 2178                to  system administrators and  programmers.  WW.WW
 2179                is the average queue  length, XX.XX is the average
 2180                eligible, YY.YY  is the thrashing index,  ZZ.ZZ is
 2181                the  average  response,  and  DDD.DD  is the total
 2182                dollar  charge since  startup.  A  shutdown of the
 2183                hardcore system follows this message.
 2184 
 2185      Action:   No operator action is required.
 2186 
 2187 
 2188                [act_ctl_.pl1]
 2189                act_ctl_:  STRING for  USER.PROJ is negative (NUM)
 2190                at logout; set it to zero.
 2191 
 2192 
 2193 
 2194      Stream:   as (severity2)
 2195 
 2196      Time:     While system is running.
 2197 
 2198      Meaning:  A counter value of STRING was decremented by 1 and
 2199                went negative.  It was  noticed when attempting to
 2200                log out USER on the  PROJ project.  This is a sign
 2201                of possible damage to the PROJ pdt.
 2202 
 2203      Action:   Note for system programmer action.
 2204 
 2205 
 2206                [act_proc.pl1]
 2207                act_proc:  from grab_aste ERRORMESSAGE
 2208 
 2209 
 2210      Stream:   BOS Typewriter (Crashes system)
 2211 
 2212      Time:     While system is running.
 2213 
 2214      Meaning:  In  attempting  to  create  a  process, the system
 2215                could not  force the PDS or  descriptor segment of
 2216 
 2217 
 2218 act_proc                        39            08/21/20     MR12.7^L
 2219 
 2220 
 2221                that  process  to  be  activated  and held active.
 2222                ERRORMESSAGE  is  an  error_table_  message.  This
 2223                indicates a logic error  in the supervisor, or CPU
 2224                or memory hardware problems.
 2225 
 2226      Action:   Follow normal recovery procedures.
 2227 
 2228 
 2229                [act_proc.pl1]
 2230                act_proc:   KST size   specified (SIZE)  less than
 2231                minimum (MIN_SIZE).  Creating process for GROUPID.
 2232 
 2233 
 2234 
 2235      Stream:   Logged in SYSERR log.
 2236 
 2237      Time:     While system is running.
 2238 
 2239      Meaning:  The     project    administrator     (or    system
 2240                administrator) for  user GROUPID set  the kst_size
 2241                parameter in  the PDT to SIZE, which  is less than
 2242                the  valid minimum  MIN_SIZE.  The  process is not
 2243                created.   Note that  a process  with MINIMUM  KST
 2244                size will probably not be of any use.  The minimum
 2245                useful KST size is on the order of MINIMUM + 50.
 2246 
 2247      Action:   Change the PMF/PDT.
 2248 
 2249 
 2250                [activate.pl1]
 2251                activate:  activating into father PPPP
 2252 
 2253 
 2254      Stream:   BOS Typewriter (Crashes system)
 2255 
 2256      Time:     While system is running.
 2257 
 2258      Meaning:  The  AST  entry  pointer  returned  by get_aste is
 2259                identical to the AST  entry pointer for the parent
 2260                of the segment being  activated.  This indicates a
 2261                logic  error in the  supervisor, or CPU  or memory
 2262                hardware   problems.    BOS   Typewriter  (Crashes
 2263                system)es
 2264 
 2265      Action:   Follow normal recovery procedures.
 2266 
 2267 
 2268                [activate.pl1]
 2269                activate:  error on (deciduous) (dir) NAME
 2270 
 2271 
 2272      Stream:   Logged in SYSERR log.
 2273 
 2274 
 2275 
 2276 activate                        40            08/21/20     MR12.7^L
 2277 
 2278 
 2279      Time:     While system is running.
 2280 
 2281      Meaning:  An attempt  has been made to  activate a deciduous
 2282                segment, or to activate a segment when the VTOCE's
 2283                directory  switch  did  not  match  the branch.  A
 2284                connection  failure   is  returned  to   the  user
 2285                process.  This  information is logged for  the use
 2286                of system programmers.
 2287 
 2288      Action:   No operator action is required.
 2289 
 2290 
 2291                [activate.pl1]
 2292                activate:  Setting damaged switch on NAME at VTOCX
 2293                (dskX_NN{s}).  Filemap damaged.
 2294 
 2295 
 2296      Stream:   Logged in SYSERR log.
 2297 
 2298      Time:     While system is running.
 2299 
 2300      Meaning:  The segment's File Map in the VTOCE had an invalid
 2301                checksum,  which indicates   likely damage  to the
 2302                File Map.   The segment is marked  as damaged.  It
 2303                is  possible that  there  is  other damage  on the
 2304                physical  volume  due  to  invalid  or reused disk
 2305                addresses.  The count of volume inconsistencies is
 2306                incremented by 1.
 2307 
 2308      Action:   Examine the VTOCE for damage using dump_vtoce.  If
 2309                other   damage  is    evident,  delete   it  using
 2310                hp_delete_vtoce  -clear and  recover the  segment.
 2311                Run  the  physical  volume  scavenger  as  soon as
 2312                possible to detect and correct other damage on the
 2313                physical volume.
 2314 
 2315 
 2316 
 2317                [obs_reconfigure.pl1]
 2318                addcpu:  Associative  memories not enabled  on CPU
 2319                X.
 2320 
 2321 
 2322      Stream:   Initializer process output.
 2323 
 2324      Time:     In response to an operator command.
 2325 
 2326      Meaning:  The SDWAM  and/or PTWAM on  CPU X is  not enabled.
 2327                CPU X was not added.
 2328 
 2329      Action:   Set the  appropriate associative memory  switch on
 2330                and try addcpu again.
 2331 
 2332 
 2333 
 2334 addcpu                          41            08/21/20     MR12.7^L
 2335 
 2336 
 2337 
 2338 
 2339                [obs_reconfigure.pl1]
 2340                addcpu:  CPU X is already online.
 2341 
 2342 
 2343      Stream:   Initializer process output.
 2344 
 2345      Time:     In response to an operator command.
 2346 
 2347      Meaning:  A  redundant  addcpu  X  command  was  issued.  No
 2348                action was taken.
 2349 
 2350      Action:   Enter a corrected command line.
 2351 
 2352 
 2353                [obs_reconfigure.pl1]
 2354                addcpu:  CPU X is not configured.
 2355 
 2356 
 2357      Stream:   Initializer process output.
 2358 
 2359      Time:     In response to an operator command.
 2360 
 2361      Meaning:  There   is  no   CPU  card   for  CPU   X  in  the
 2362                configuration deck.  The CPU cannot be added.
 2363 
 2364      Action:   If  the CPU name  was mistyped, enter  a corrected
 2365                command.   If the  configuration deck  omitted the
 2366                CPU  card,  that  CPU  cannot  be  added until the
 2367                system is shut down and the deck corrected.
 2368 
 2369 
 2370 
 2371                [obs_reconfigure.pl1]
 2372                addcpu:  CPU X is not enabled at MEM Y.
 2373 
 2374 
 2375      Stream:   Initializer process output.
 2376 
 2377      Time:     In response to an operator command.
 2378 
 2379      Meaning:  CPU  X cannot  be  added  because the  PORT ENABLE
 2380                switch at MEM Y does not enable it.
 2381 
 2382      Action:   Fix the switches and try addcpu again.
 2383 
 2384 
 2385                [obs_reconfigure.pl1]
 2386                addcpu:  CPU X is not in Multics mode.
 2387 
 2388 
 2389      Stream:   Initializer process output.
 2390 
 2391 
 2392 addcpu                          42            08/21/20     MR12.7^L
 2393 
 2394 
 2395      Time:     In response to an operator command.
 2396 
 2397      Meaning:  CPU X  cannot be added because its  mode switch is
 2398                wrong.
 2399 
 2400      Action:   Fix the switch and try again.
 2401 
 2402 
 2403                [obs_reconfigure.pl1]
 2404                addcpu:   Illegal command or  subroutine argument.
 2405                BLAH
 2406 
 2407 
 2408      Stream:   Initializer process output.
 2409 
 2410      Time:     In response to an operator command.
 2411 
 2412      Meaning:  Invalid input was typed.
 2413 
 2414      Action:   Enter a corrected command line.
 2415 
 2416 
 2417                [obs_reconfigure.pl1]
 2418                addcpu:  Lockup fault trying to start CPU X.
 2419 
 2420 
 2421      Stream:   Initializer process output.
 2422 
 2423      Time:     In response to an operator command.
 2424 
 2425      Meaning:  This happens  occasionally.  The reason for  it is
 2426                unknown.
 2427 
 2428      Action:   Try addcpu a few more times.
 2429 
 2430 
 2431                [obs_reconfigure.pl1]
 2432                addcpu:  No response from CPU X.
 2433 
 2434 
 2435      Stream:   Initializer process output.
 2436 
 2437      Time:     In response to an operator command.
 2438 
 2439      Meaning:  CPU X did not start  up when commanded.  It may be
 2440                malfunctioning or in STEP.
 2441 
 2442      Action:   Check  the switches.   If any  are wrong,  correct
 2443                them  and retry  addcpu.  Otherwise,  notify Field
 2444                Engineering.
 2445 
 2446 
 2447 
 2448 
 2449 
 2450 addcpu                          43            08/21/20     MR12.7^L
 2451 
 2452 
 2453 
 2454 
 2455                [obs_reconfigure.pl1]
 2456                addcpu:  Reconfiguration database is locked.
 2457 
 2458 
 2459      Stream:   Initializer process output.
 2460 
 2461      Time:     In response to an operator command.
 2462 
 2463      Meaning:  Another  process   is  performing  reconfiguration
 2464                currently, or  a fault during  reconfiguration has
 2465                left the reconfiguration tables locked.
 2466 
 2467      Action:   If  it  is  certain   that  no  other  process  is
 2468                reconfiguring,   and   that    the   fault   which
 2469                interrupted  reconfiguration has  been cured,  the
 2470                reconfigure$force_unlock  command may  be used  to
 2471                clear the lock at the direction of system staff.
 2472 
 2473 
 2474 
 2475                [obs_reconfigure.pl1]
 2476                addcpu:  Startup fault trying to start CPU X.
 2477 
 2478 
 2479      Stream:   Initializer process output.
 2480 
 2481      Time:     In response to an operator command.
 2482 
 2483      Meaning:  This happens sometimes.  Nobody knows why.
 2484 
 2485      Action:   Try again a few times.
 2486 
 2487 
 2488                [obs_reconfigure.pl1]
 2489                addcpu:  The  following switches on CPU  X are set
 2490                incorrectly:
 2491                Fault Base
 2492                Processor Number
 2493                Port Assignment MEM Y
 2494                Port Enable MEM Y
 2495                Interlace MEM Y
 2496                Size MEM Y
 2497                Half/Full MEM Y
 2498 
 2499 
 2500 
 2501      Stream:   Initializer process output.
 2502 
 2503      Time:     In response to an operator command.
 2504 
 2505      Meaning:  The listed switches are set incorrectly.
 2506 
 2507 
 2508 addcpu                          44            08/21/20     MR12.7^L
 2509 
 2510 
 2511      Action:   Correct the switches and try addcpu again.
 2512 
 2513 
 2514                [obs_reconfigure.pl1]
 2515                addcpu:  Trouble fault trying to start CPU X.
 2516 
 2517 
 2518      Stream:   Initializer process output.
 2519 
 2520      Time:     In response to an operator command.
 2521 
 2522      Meaning:  This happens sometimes.  Nobody knows why.
 2523 
 2524      Action:   Try again a few times.
 2525 
 2526 
 2527                [obs_reconfigure.pl1]
 2528                addcpu:  Wrong number of arguments supplied.
 2529 
 2530 
 2531      Stream:   Initializer process output.
 2532 
 2533      Time:     In response to an operator command.
 2534 
 2535      Meaning:  Invalid input was typed.
 2536 
 2537      Action:   Enter a corrected command line.
 2538 
 2539 
 2540                [obs_reconfigure.pl1]
 2541                Added frame XXX.
 2542 
 2543 
 2544      Stream:   Initializer process output.
 2545 
 2546      Time:     In response to an operator command.
 2547 
 2548      Meaning:  This is  the response to a  successful addmain XXX
 2549                command.
 2550 
 2551      Action:   No operator action is required.
 2552 
 2553 
 2554                [obs_reconfigure.pl1]
 2555                Added frames XXX thru YYY.
 2556 
 2557 
 2558      Stream:   Initializer process output.
 2559 
 2560      Time:     In response to an operator command.
 2561 
 2562      Meaning:  This is the response to a successful addmain XXX N
 2563                command.
 2564 
 2565 
 2566 Added                           45            08/21/20     MR12.7^L
 2567 
 2568 
 2569      Action:   No operator action is required.
 2570 
 2571 
 2572                [disk_table_.pl1]
 2573                added pv PVNAME to mounted lv LVNAME.
 2574 
 2575 
 2576      Stream:   Initializer process output.
 2577 
 2578      Time:     While system is running.
 2579 
 2580      Meaning:  An av command  was used to increase the  size of a
 2581                mounted volume.
 2582 
 2583      Action:   No operator action is required.
 2584 
 2585 
 2586                [obs_reconfigure.pl1]
 2587                Added SCU X and its memory.
 2588 
 2589 
 2590      Stream:   Initializer process output.
 2591 
 2592      Time:     In response to an operator command.
 2593 
 2594      Meaning:  This  is the  response  to  a successful  addmem X
 2595                command.
 2596 
 2597      Action:   No operator action is required.
 2598 
 2599 
 2600                [obs_reconfigure.pl1]
 2601                Added SCU's X and Y (interlaced) and their memory.
 2602 
 2603 
 2604      Stream:   Initializer process output.
 2605 
 2606      Time:     In response to an operator command.
 2607 
 2608      Meaning:  This  is the  response  to  a successful  addmem X
 2609                command  when SCU's  X and  Y have  their memories
 2610                interlaced.
 2611 
 2612      Action:   No operator action is required.
 2613 
 2614 
 2615                [obs_reconfigure.pl1]
 2616                addmain:  Illegal command  or subroutine argument.
 2617                BLAH
 2618 
 2619 
 2620      Stream:   Initializer process output.
 2621 
 2622 
 2623 
 2624 addmain                         46            08/21/20     MR12.7^L
 2625 
 2626 
 2627      Time:     In response to an operator command.
 2628 
 2629      Meaning:  Invalid input was typed.
 2630 
 2631      Action:   Enter a corrected command line.
 2632 
 2633 
 2634                [obs_reconfigure.pl1]
 2635                addmain:  Reconfiguration database is locked.
 2636 
 2637 
 2638      Stream:   Initializer process output.
 2639 
 2640      Time:     In response to an operator command.
 2641 
 2642      Meaning:  Another  process   is  performing  reconfiguration
 2643                currently, or  a fault during  reconfiguration has
 2644                left the reconfiguration tables locked.
 2645 
 2646      Action:   If  it  is  certain   that  no  other  process  is
 2647                reconfiguring,   and   that    the   fault   which
 2648                interrupted  reconfiguration has  been cured,  the
 2649                reconfigure$force_unlock  command may  be used  to
 2650                clear the lock at the direction of system staff.
 2651 
 2652 
 2653 
 2654                [obs_reconfigure.pl1]
 2655                addmain:  Request is not  within range of a single
 2656                controller.  MAIN XXX
 2657 
 2658 
 2659      Stream:   Initializer process output.
 2660 
 2661      Time:     In response to an operator command.
 2662 
 2663      Meaning:  An addmain command  must specify memory completely
 2664                within the range of a single controller.
 2665 
 2666      Action:   Enter a corrected command line.
 2667 
 2668 
 2669                [obs_reconfigure.pl1]
 2670                addmain:  Wrong number of arguments supplied.
 2671 
 2672 
 2673      Stream:   Initializer process output.
 2674 
 2675      Time:     In response to an operator command.
 2676 
 2677      Meaning:  Invalid input was typed.
 2678 
 2679      Action:   Enter a corrected command line.
 2680 
 2681 
 2682 addmem                          47            08/21/20     MR12.7^L
 2683 
 2684 
 2685 
 2686 
 2687                [add_scu.pl1]
 2688                addmem:  Added MEM X.
 2689 
 2690 
 2691      Stream:   BOS Typewriter.
 2692 
 2693      Time:     In response to an operator command.
 2694 
 2695      Meaning:  The system control unit X has been added.
 2696 
 2697      Action:   No operator action is required.
 2698 
 2699 
 2700                [obs_reconfigure.pl1]
 2701                addmem:   Illegal command or  subroutine argument.
 2702                BLAH
 2703 
 2704 
 2705      Stream:   Initializer process output.
 2706 
 2707      Time:     In response to an operator command.
 2708 
 2709      Meaning:  Invalid input was typed.
 2710 
 2711      Action:   Enter a corrected command line.
 2712 
 2713 
 2714                [obs_reconfigure.pl1]
 2715                addmem:  MEM Y cannot be accessed by CPU X.
 2716 
 2717 
 2718      Stream:   Initializer process output.
 2719 
 2720      Time:     In response to an operator command.
 2721 
 2722      Meaning:  CPU   X  is   unable   to   access  MEM   Y.   The
 2723                configuration  deck may  be incorrect,  or the CPU
 2724                and SCU switches may be in the wrong settings.
 2725 
 2726      Action:   Check the  switches and make sure  that they agree
 2727                with  the  configuration  deck.   Then  try addmem
 2728                again.
 2729 
 2730 
 2731 
 2732                [obs_reconfigure.pl1]
 2733                addmem:  MEM Y does not  have mask assigned to CPU
 2734                X.
 2735 
 2736 
 2737      Stream:   Initializer process output.
 2738 
 2739 
 2740 addmem                          48            08/21/20     MR12.7^L
 2741 
 2742 
 2743      Time:     In response to an operator command.
 2744 
 2745      Meaning:  The  MASK/PORT  ASSIGNMENT  (4MW  SCU)  or EXECUTE
 2746                INTERRUPT MASK  ASSIGNMENT (6000 SCU)  switches on
 2747                SCU Y are incorrect.
 2748 
 2749      Action:   Fix the switches and try addmem again.
 2750 
 2751 
 2752                [obs_reconfigure.pl1]
 2753                addmem:  MEM  Y has duplicate mask  assignments to
 2754                CPU X.
 2755 
 2756 
 2757      Stream:   Initializer process output.
 2758 
 2759      Time:     In response to an operator command.
 2760 
 2761      Meaning:  The  MASK/PORT  ASSIGNMENT  (4MW  SCU)  or EXECUTE
 2762                INTERRUPT MASK  ASSIGNMENT (6000 SCU)  switches on
 2763                SCU Y are incorrect.
 2764 
 2765      Action:   Fix the switches and try addmem again.
 2766 
 2767 
 2768                [obs_reconfigure.pl1]
 2769                addmem:   MEM Y  has  mask  Z assigned  to non-CPU
 2770                port.
 2771 
 2772 
 2773      Stream:   Initializer process output.
 2774 
 2775      Time:     In response to an operator command.
 2776 
 2777      Meaning:  The  MASK/PORT  ASSIGNMENT  (4MW  SCU)  or EXECUTE
 2778                INTERRUPT MASK  ASSIGNMENT (6000 SCU)  switches on
 2779                SCU Y are incorrect.
 2780 
 2781      Action:   Fix the switches and try addmem again.
 2782 
 2783 
 2784                [obs_reconfigure.pl1]
 2785                addmem:  MEM Y is already online.
 2786 
 2787 
 2788      Stream:   Initializer process output.
 2789 
 2790      Time:     In response to an operator command.
 2791 
 2792      Meaning:  An  addmem Y  command was   typed when  SCU Y  was
 2793                already online.
 2794 
 2795      Action:   No operator action is required.
 2796 
 2797 
 2798 addmem                          49            08/21/20     MR12.7^L
 2799 
 2800 
 2801 
 2802 
 2803                [obs_reconfigure.pl1]
 2804                addmem:  MEM Y is not configured.
 2805 
 2806 
 2807      Stream:   Initializer process output.
 2808 
 2809      Time:     In response to an operator command.
 2810 
 2811      Meaning:  There is no MEM card  in the configuration for MEM
 2812                y.  The SCU cannot be added.
 2813 
 2814      Action:   If  the SCU name  was mistyped, enter  a corrected
 2815                command.   If the  configuration deck  omitted the
 2816                MEM card, the SCU cannot be added until the system
 2817                is shut down and the deck corrected.
 2818 
 2819 
 2820 
 2821                [obs_reconfigure.pl1]
 2822                addmem:  MEM Y is not enabled on CPU X.
 2823 
 2824 
 2825      Stream:   Initializer process output.
 2826 
 2827      Time:     In response to an operator command.
 2828 
 2829      Meaning:  The  ENABLE switch  on the  CONFIGURATION panel of
 2830                CPU X does not enable SCU Y.  The memory cannot be
 2831                added.
 2832 
 2833      Action:   Fix the switches and try addmem again.
 2834 
 2835 
 2836                [obs_reconfigure.pl1]
 2837                addmem:  MEM Y is not in PROGRAM mode.
 2838 
 2839 
 2840      Stream:   Initializer process output.
 2841 
 2842      Time:     In response to an operator command.
 2843 
 2844      Meaning:  The  MODE switch on  4MW SCU Y  is not in  PROGRAM
 2845                mode.  The SCU cannot be added.
 2846 
 2847      Action:   Fix the switches and try addmem again.
 2848 
 2849      Action:   No operator action is required.
 2850 
 2851 
 2852                [obs_reconfigure.pl1]
 2853                addmem:  Reconfiguration database is locked.
 2854 
 2855 
 2856 addmem                          50            08/21/20     MR12.7^L
 2857 
 2858 
 2859      Stream:   Initializer process output.
 2860 
 2861      Time:     In response to an operator command.
 2862 
 2863      Meaning:  Another  process   is  performing  reconfiguration
 2864                currently, or  a fault during  reconfiguration has
 2865                left the reconfiguration tables locked.
 2866 
 2867      Action:   If  it  is  certain   that  no  other  process  is
 2868                reconfiguring,   and   that    the   fault   which
 2869                interrupted  reconfiguration has  been cured,  the
 2870                reconfigure$force_unlock  command may  be used  to
 2871                clear the lock at the direction of system staff.
 2872 
 2873 
 2874 
 2875                [obs_reconfigure.pl1]
 2876                addmem:   Size   of  MEM  Y  disagrees   with  CPU
 2877                switches.
 2878 
 2879 
 2880      Stream:   Initializer process output.
 2881 
 2882      Time:     In response to an operator command.
 2883 
 2884      Meaning:  The memory size on  the configuration card for MEM
 2885                Y disagrees with the size on the CPU switches.
 2886 
 2887      Action:   If  the switches are  incorrect, fix them  and try
 2888                addmem  again.   If   the  configuration  deck  is
 2889                incorrect,  the system must  be shut down  and the
 2890                deck corrected before the SCU can be added.
 2891 
 2892 
 2893 
 2894                [obs_reconfigure.pl1]
 2895                addmem:  Switches for MEM  Y set improperly on CPU
 2896                X.
 2897 
 2898 
 2899      Stream:   Initializer process output.
 2900 
 2901      Time:     In response to an operator command.
 2902 
 2903      Meaning:  The  ADDRESS  ASSIGNMENT  switches  for  SCU Y are
 2904                incorrect on CPU X.
 2905 
 2906      Action:   Correct the switches and try addmem again.
 2907 
 2908 
 2909                [obs_reconfigure.pl1]
 2910                addmem:  Wrong number of arguments supplied.
 2911 
 2912 
 2913 
 2914 addmem                          51            08/21/20     MR12.7^L
 2915 
 2916 
 2917      Stream:   Initializer process output.
 2918 
 2919      Time:     In response to an operator command.
 2920 
 2921      Meaning:  Invalid input was typed.
 2922 
 2923      Action:   Enter a corrected command line.
 2924 
 2925 
 2926                [admin_.pl1]
 2927                admin_:   abs   ABS_FUNCTION:   Expected  argument
 2928                missing.  After PREV_ARG.
 2929 
 2930 
 2931      Stream:   as (severity 1)
 2932 
 2933      Time:     In response to an operator abs command.
 2934 
 2935      Meaning:  A required value to a control argument supplied in
 2936                the "abs" command line is missing.
 2937 
 2938      Action:   Reenter corrected command line.
 2939 
 2940 
 2941                [admin_.pl1]
 2942                admin_:  abs:  ABS_FUNCT:  error:  absentee not up
 2943 
 2944 
 2945      Stream:   as (severity 1)
 2946 
 2947      Time:     In response to an operator command.
 2948 
 2949      Meaning:  An  abs  command  was   given,  but  the  absentee
 2950                facility had never been started up.  No action was
 2951                taken on the command.
 2952 
 2953      Action:   Type abs start to start up the absentee facility.
 2954 
 2955 
 2956                [admin_.pl1]
 2957                admin_:  abs:  ABS_FUNCT:  error:  Invalid abs job
 2958                selection argument:  SSSS
 2959 
 2960 
 2961      Stream:   as (severity 1)
 2962 
 2963      Time:     In response to an operator command.
 2964 
 2965      Meaning:  The job selection argument  SSSS is not recognized
 2966                as valid.
 2967 
 2968      Action:   Type  "help abs"  for details  of the  abs command
 2969                usage and try again.
 2970 
 2971 
 2972 admin_                          52            08/21/20     MR12.7^L
 2973 
 2974 
 2975 
 2976 
 2977                [admin_.pl1]
 2978                admin_:  abs:  ABS_FUNCT:  error:  Job in absentee
 2979                slot X does not match absin entry name SSSS
 2980 
 2981 
 2982      Stream:   as (severity 1)
 2983 
 2984      Time:     In response to an operator command.
 2985 
 2986      Meaning:  The  entry  name  SSSS  of  the  absin  of the job
 2987                running  in specified  absentee slot  of absX does
 2988                not match the specified absin entry name.
 2989 
 2990      Action:   Recheck job specifications and try again.
 2991 
 2992 
 2993                [admin_.pl1]
 2994                admin_:  abs:  ABS_FUNCT:  error:  Job in absentee
 2995                slot    X    does    not    match    absin    path
 2996                DIR_PATH>ENTRY_NAME
 2997 
 2998 
 2999      Stream:   as (severity 1)
 3000 
 3001      Time:     In response to an operator command.
 3002 
 3003      Meaning:  The pathname  of the absin  of the job  running in
 3004                specified absentee slot of absX does not match the
 3005                specified absin pathname.
 3006 
 3007      Action:   Recheck job specifications and try again.
 3008 
 3009 
 3010                [admin_.pl1]
 3011                admin_:  abs:  ABS_FUNCT:  error:  Job in absentee
 3012                slot X does not match request ID YYYY
 3013 
 3014 
 3015      Stream:   as (severity 1)
 3016 
 3017      Time:     In response to an operator command.
 3018 
 3019      Meaning:  The  ID of the  job running in  specified absentee
 3020                slot of  absX does not  match the specified  ID of
 3021                YYYY.
 3022 
 3023      Action:   Recheck job specifications and try again.
 3024 
 3025 
 3026                [admin_.pl1]
 3027 
 3028 
 3029 
 3030 admin_                          53            08/21/20     MR12.7^L
 3031 
 3032 
 3033                admin_:  abs:  ABS_FUNCT:  error:  Job in absentee
 3034                slot X is not from queue DDDD
 3035 
 3036 
 3037      Stream:   as (severity 1)
 3038 
 3039      Time:     In response to an operator command.
 3040 
 3041      Meaning:  The  queue of  the absin   of the  job running  in
 3042                specified absentee slot of absX does not match the
 3043                queue number DDDD.
 3044 
 3045      Action:   Recheck job specifications and try again.
 3046 
 3047 
 3048                [admin_.pl1]
 3049                admin_:  abs:  ABS_FUNCT:  error:  Job in absentee
 3050                slot X is not from sender SSSS
 3051 
 3052 
 3053      Stream:   as (severity 1)
 3054 
 3055      Time:     In response to an operator command.
 3056 
 3057      Meaning:  The  sender of  the absin  of the  job running  in
 3058                specified absentee slot of absX does not match the
 3059                specified sender, SSSS.
 3060 
 3061      Action:   Recheck job specifications and try again.
 3062 
 3063 
 3064                [admin_.pl1]
 3065                admin_:  abs:  ABS_FUNCT:  error:  Job in absentee
 3066                slot X is not from user NAME.PROJ
 3067 
 3068 
 3069      Stream:   as (severity 1)
 3070 
 3071      Time:     In response to an operator command.
 3072 
 3073      Meaning:  The job running in specified absentee slot of absX
 3074                is not from specified user, NAME.PROJ.
 3075 
 3076      Action:   Recheck job specifications and try again.
 3077 
 3078 
 3079                [admin_.pl1]
 3080                admin_:  abs:   ABS_FUNCT:  error:  More  than one
 3081                specification of an attribute is present:  SSSS
 3082 
 3083 
 3084      Stream:   as (severity 1)
 3085 
 3086 
 3087 
 3088 admin_                          54            08/21/20     MR12.7^L
 3089 
 3090 
 3091      Time:     In response to an operator command.
 3092 
 3093      Meaning:  The SSSS  attribute has already been  specified to
 3094                select  an  absentee  job   on  the  operator  abs
 3095                command.  An attribute can only be used once.
 3096 
 3097      Action:   Enter a corrected command line.
 3098 
 3099 
 3100                [admin_.pl1]
 3101                admin_:   abs:   ABS_FUNCT:   error:   No  job  in
 3102                absentee slot X (status= SSSS).
 3103 
 3104 
 3105      Stream:   as (severity 1)
 3106 
 3107      Time:     In response to an operator command.
 3108 
 3109      Meaning:  The absentee slot absX has an entry status of SSSS
 3110                indicating that no user is using it.
 3111 
 3112      Action:   Enter a corrected command line.
 3113 
 3114 
 3115                [admin_.pl1]
 3116                admin_:  abs:  ABS_FUNCT:  error:  Personid NAME >
 3117                22 characters.
 3118 
 3119 
 3120      Stream:   as (severity 1)
 3121 
 3122      Time:     In response to an operator command.
 3123 
 3124      Meaning:  The "abs  ABS_FUNCT" operator command  specified a
 3125                user name that is longer than 22 characters.
 3126 
 3127      Action:   Enter a corrected command line.
 3128 
 3129 
 3130                [admin_.pl1]
 3131                admin_:  abs:  ABS_FUNCT:   error:  Projectid SSSS
 3132                is longer than 9 characters.
 3133 
 3134 
 3135      Stream:   as (severity 1)
 3136 
 3137      Time:     In response to an operator command.
 3138 
 3139      Meaning:  The  "abs ABS_FUNCT" operator  command incorrectly
 3140                specified  a project  name that  is longer  than 9
 3141                characters.
 3142 
 3143      Action:   Enter a corrected command line.
 3144 
 3145 
 3146 admin_                          55            08/21/20     MR12.7^L
 3147 
 3148 
 3149 
 3150 
 3151                [admin_.pl1]
 3152                admin_:    abs:    ABS_FUNCT:    error:   Relative
 3153                pathnames not allowed:  SSSS
 3154 
 3155 
 3156      Stream:   as (severity 1)
 3157 
 3158      Time:     In response to an operator command.
 3159 
 3160      Meaning:  The pathname of the absin was expected and it must
 3161                be  an  absolute  pathname,  starting  with  a ">"
 3162                character.
 3163 
 3164      Action:   Enter a corrected command line.
 3165 
 3166 
 3167                [admin_.pl1]
 3168                admin_:    abs:   ABS_FUNCT:    error:   Selection
 3169                arguments matched no running absentee jobs.
 3170 
 3171 
 3172      Stream:   as (severity 1)
 3173 
 3174      Time:     In response to an operator command.
 3175 
 3176      Meaning:  No  running   job  was  found  that   matched  the
 3177                selection  arguments supplied  on the  abs command
 3178                line.
 3179 
 3180      Action:   Recheck job specifications and try again.
 3181 
 3182 
 3183                [admin_.pl1]
 3184                admin_:  abs:   ABS_FUNCT:  error:  SSSS is  not a
 3185                valid Person.Project.
 3186 
 3187 
 3188      Stream:   as (severity 1)
 3189 
 3190      Time:     In response to an operator command.
 3191 
 3192      Meaning:  The  "abs  ABS_FUNCT"  operator  command  did  not
 3193                specify a valid Person.Project in the string SSSS.
 3194 
 3195      Action:   Enter a corrected command line.
 3196 
 3197 
 3198                [admin_.pl1]
 3199                admin_:    abs:   ABS_FUNCT:   error:    The  absN
 3200                argument is not valid.
 3201 
 3202 
 3203 
 3204 admin_                          56            08/21/20     MR12.7^L
 3205 
 3206 
 3207      Stream:   as (severity 1)
 3208 
 3209      Time:     In response to an operator command.
 3210 
 3211      Meaning:  The "abs ABS_FUNCT"  operator command cannot allow
 3212                use of the absN argument for job selection.
 3213 
 3214      Action:   Enter a corrected command line.
 3215 
 3216 
 3217                [admin_.pl1]
 3218                admin_:  abs:  ABS_FUNCT:   error:  User name (not
 3219                ""*"") must be given.
 3220 
 3221 
 3222      Stream:   as (severity 1)
 3223 
 3224      Time:     In response to an operator command.
 3225 
 3226      Meaning:  The "abs ABS_FUNCT" operator command requires that
 3227                a user name be supplied.  Cannot use "*".
 3228 
 3229      Action:   Enter a corrected command line.
 3230 
 3231 
 3232                [admin_.pl1]
 3233                admin_:  abs:  ABS_FUNCT:   error:  User name must
 3234                be given.
 3235 
 3236 
 3237      Stream:   as (severity 1)
 3238 
 3239      Time:     In response to an operator command.
 3240 
 3241      Meaning:  The "abs ABS_FUNCT" operator command requires that
 3242                a user name be supplied.
 3243 
 3244      Action:   Enter a corrected command line.
 3245 
 3246 
 3247                [admin_.pl1]
 3248                admin_:   abs:  ABS_FUNCT:   Invalid queue  number
 3249                DDDD
 3250 
 3251 
 3252      Stream:   as (severity 1)
 3253 
 3254      Time:     In response to an operator command.
 3255 
 3256      Meaning:  The value after the  -queue job selection argument
 3257                is  invalid.   It  must  be  the  strings  "fg" or
 3258                "foreground" or  a between the values of  1 and 4,
 3259                inclusive.
 3260 
 3261 
 3262 admin_                          57            08/21/20     MR12.7^L
 3263 
 3264 
 3265      Action:   Enter a corrected command line.
 3266 
 3267 
 3268                [admin_.pl1]
 3269                admin_:    abs:   ABS_FUNCT:   No   job  selection
 3270                arguments given.
 3271 
 3272 
 3273      Stream:   as (severity 1)
 3274 
 3275      Time:     In response to an operator command.
 3276 
 3277      Meaning:  After  processing   the  arguments  on   the  "abs
 3278                abs_funct"  operator  command,  no  job  selection
 3279                arguments were encountered.
 3280 
 3281      Action:   Type  "help abs"  for details  of the  abs command
 3282                usage and try again.
 3283 
 3284 
 3285                [admin_.pl1]
 3286                admin_:   abs:  absentee not  up, and will  not be
 3287                started automatically
 3288 
 3289 
 3290      Stream:   as (severity 1)
 3291 
 3292      Time:     When operator  entered "abs stop"  before absentee
 3293                facility was started.
 3294 
 3295      Meaning:  The command can be  entered at standard to prevent
 3296                the    absentee   facility   from    starting   up
 3297                automatically after a "startup" command is used.
 3298 
 3299      Action:   No operator action is required.
 3300 
 3301 
 3302                [admin_.pl1]
 3303                admin_:  abs:  All absentee  processes have run to
 3304                completion.
 3305 
 3306 
 3307      Stream:   as (severity 1)
 3308 
 3309      Time:     When shutting down the absentee facility.
 3310 
 3311      Meaning:  This  message is  printed after  the operator  has
 3312                issued  an  abs  stop  command  or  the system has
 3313                issued  an automatic  abs stop  prior to shutdown.
 3314                The system allows 30 minutes for all absentee jobs
 3315                to finish before logging them out, then prints the
 3316                message.
 3317 
 3318 
 3319 
 3320 admin_                          58            08/21/20     MR12.7^L
 3321 
 3322 
 3323      Action:   It is now safe to proceed with the shutdown.
 3324 
 3325 
 3326                [admin_.pl1]
 3327                admin_:  abs:   auto abs stop will  be at MM/DD/YY
 3328                HHMM.T
 3329 
 3330 
 3331      Stream:   as (severity 1)
 3332 
 3333      Time:     In  response to  an  operator  down command  or at
 3334                startup.
 3335 
 3336      Meaning:  This  is the  response to  a down  command if  the
 3337                absentee facility  is running, or to  an abs start
 3338                command if the absentee is brought up after a down
 3339                time has been set.  The  time for an automatic abs
 3340                stop is  20 minutes before  the system is  to shut
 3341                down.  An "abs stop now"  is done 10 minutes after
 3342                the  scheduled shutdown.   Refer also  to the stop
 3343                command description.
 3344 
 3345      Action:   No operator action is required.
 3346 
 3347 
 3348                [admin_.pl1]
 3349                admin_:   abs:   Bumping  all  remaining  absentee
 3350                processes.
 3351 
 3352 
 3353      Stream:   as (severity 1)
 3354 
 3355      Time:     System shutdown.
 3356 
 3357      Meaning:  The  absentee facility  waits 30  minutes for  all
 3358                absentee jobs  to run to completion  after the abs
 3359                stop command has been  issued.  Then it types this
 3360                message  and bumps  them all.   Refer also  to the
 3361                stop command description.
 3362 
 3363      Action:   No operator action is required.
 3364 
 3365 
 3366                [admin_.pl1]
 3367                admin_:  abs:   cpu_limit (MMMM), queues  1-4:  WW
 3368                XX YY ZZ (seconds)
 3369 
 3370 
 3371      Stream:   as (severity 1)
 3372 
 3373      Time:     In  response to   "abs cpu_limit"  command without
 3374                arguments.
 3375 
 3376 
 3377 
 3378 admin_                          59            08/21/20     MR12.7^L
 3379 
 3380 
 3381      Meaning:  Informative  message indicating current  values of
 3382                cpu_limit  for each  absentee queue.   MMM is  the
 3383                mode, "auto" or "manual".
 3384 
 3385      Action:   No operator action is required.
 3386 
 3387 
 3388                [admin_.pl1]
 3389                admin_:  abs:  cpu_limit:  error:  Usage is:  "abs
 3390                cpu_limit l1,l2,l3,l4" (limits in seconds)
 3391 
 3392 
 3393      Stream:   as (severity 1)
 3394 
 3395      Time:     In response to an operator command.
 3396 
 3397      Meaning:  Informative  message  that  is  displayed  when an
 3398                operator "abs cpu_limit" command without arguments
 3399                is entered.
 3400 
 3401      Action:   Enter a corrected command line.
 3402 
 3403 
 3404                [admin_.pl1]
 3405                admin_:   abs:  error:   The abs  CCCC command can
 3406                not be used before answering service startup.
 3407 
 3408 
 3409      Stream:   as (severity 1)
 3410 
 3411      Time:     In response to an operator abs command.
 3412 
 3413      Meaning:  Only  the "abs stop"  command may be  given before
 3414                the answering service starts  up.  This allows the
 3415                operator to stop the  absentee facility before the
 3416                system finishes initialzation.
 3417 
 3418      Action:   Enter a corrected command line.
 3419 
 3420 
 3421                [admin_.pl1]
 3422                admin_:   abs:  error:   unknown absentee  command
 3423                WXYZ
 3424 
 3425 
 3426      Stream:   as (severity 1)
 3427 
 3428      Time:     In response to an operator command.
 3429 
 3430      Meaning:  The  operator  typed  abs   WXYZ  where  WXYZ  was
 3431                unrecognizable  to  the  system.   No  action  was
 3432                taken.
 3433 
 3434 
 3435 
 3436 admin_                          60            08/21/20     MR12.7^L
 3437 
 3438 
 3439      Action:   Enter a corrected command line.
 3440 
 3441 
 3442                [admin_.pl1]
 3443                admin_:  abs:  ERROR_TABLE_MESSAGE PATHNAME
 3444 
 3445 
 3446      Stream:   as (severity 1)
 3447 
 3448      Time:     In response to the operator abs command.
 3449 
 3450      Meaning:  The   ERROR_TABLE_MESSAGE  was   encountered  when
 3451                trying  to  expand  the  PATHNAME  supplied in the
 3452                operator abs command line.
 3453 
 3454      Action:   Enter a corrected command line.
 3455 
 3456 
 3457                [admin_.pl1]
 3458                admin_:  abs:   list:  error:  No job  in absentee
 3459                slot X.
 3460 
 3461 
 3462      Stream:   as (severity 1)
 3463 
 3464      Time:     In response to an operator command.
 3465 
 3466      Meaning:  The absentee slot absX does not exist.
 3467 
 3468      Action:   Enter a corrected command line.
 3469 
 3470 
 3471                [admin_.pl1]
 3472                admin_:   abs:  list:   error:  The  absN argument
 3473                cannot be used when absentee is not up.
 3474 
 3475 
 3476      Stream:   as (severity 1)
 3477 
 3478      Time:     $reponse
 3479 
 3480      Meaning:  Cannot use the "absN"  argument to select absentee
 3481                jobs to list until  the absentee facility has been
 3482                started.
 3483 
 3484      Action:   Use  other  job  selection  criteria  or type "abs
 3485                start" and try again.
 3486 
 3487 
 3488                [admin_.pl1]
 3489                admin_:  abs:  maxq (MMMM):  Q
 3490 
 3491 
 3492 
 3493 
 3494 admin_                          61            08/21/20     MR12.7^L
 3495 
 3496 
 3497      Stream:   as (severity 1)
 3498 
 3499      Time:     In response to "abs maxq" without arguments.
 3500 
 3501      Meaning:  Informative  message indicating current  status of
 3502                maxq  and queue  last searched  (Q).  MMMM  is the
 3503                mode, "auto" or "manual".
 3504 
 3505      Action:   No operator action is required.
 3506 
 3507 
 3508                [admin_.pl1]
 3509                admin_:   abs:  maxq:    error:  abs  maxqueue has
 3510                invalid value:  XXX
 3511 
 3512 
 3513      Stream:   as (severity 1)
 3514 
 3515      Time:     In response to an operator command.
 3516 
 3517      Meaning:  An  abs  maxq  or  abs  start  command  had  as an
 3518                argument something  that was not a  number, or was
 3519                too big,  or was a negative number.   No action is
 3520                taken.
 3521 
 3522      Action:   Enter a corrected command line.
 3523 
 3524 
 3525                [admin_.pl1]
 3526                admin_:  abs:  maxu (MMMM):  UUUU
 3527 
 3528 
 3529      Stream:   as (severity 1)
 3530 
 3531      Time:     In response to "abs maxu" operator command without
 3532                arguments.
 3533 
 3534      Meaning:  Informative  message indicating current  status of
 3535                maxu and maximum absentee  users allowed.  MMMM is
 3536                the  mode,  "auto"  or   "manual".   UUUU  is  the
 3537                load_units.
 3538 
 3539      Action:   No operator action is required.
 3540 
 3541 
 3542                [admin_.pl1]
 3543                admin_:  abs:  maxu:  error:  abs maxusers may not
 3544                be greater than system maxusers:  SSSS
 3545 
 3546 
 3547      Stream:   as (severity 1)
 3548 
 3549      Time:     In response to an operator command.
 3550 
 3551 
 3552 admin_                          62            08/21/20     MR12.7^L
 3553 
 3554 
 3555      Meaning:  The  argument, SSSS,  to the  operator "abs  maxu"
 3556                command cannot be greater than the maximum allowed
 3557                users that can be on the system.
 3558 
 3559      Action:   Enter a corrected command line.
 3560 
 3561 
 3562                [admin_.pl1]
 3563                admin_:  abs:  maxu:  error:  abs maxusers may not
 3564                be negative:  SSSS
 3565 
 3566 
 3567      Stream:   as (severity 1)
 3568 
 3569      Time:     In response to an operator command.
 3570 
 3571      Meaning:  The  argument, SSSS,  to the  operator "abs  maxu"
 3572                command was not a  positive numeric or the string,
 3573                "auto".  The numeric value is  in tenths of a load
 3574                unit.
 3575 
 3576      Action:   Enter a corrected command line.
 3577 
 3578 
 3579                [admin_.pl1]
 3580                admin_:  abs:  maxu:  error:  abs maxusers must be
 3581                numeric or "auto":  SSSS
 3582 
 3583 
 3584      Stream:   as (severity 1)
 3585 
 3586      Time:     In response to an operator command.
 3587 
 3588      Meaning:  The  argument, SSSS,  to the  operator "abs  maxu"
 3589                command was not a  positive numeric or the string,
 3590                "auto".  The numeric value is  in tenths of a load
 3591                unit.
 3592 
 3593      Action:   Enter a corrected command line.
 3594 
 3595 
 3596                [admin_.pl1]
 3597                admin_:  abs:  qres (MMMM):  WW XX YY ZZ
 3598 
 3599 
 3600      Stream:   as (severity 1)
 3601 
 3602      Time:     In response to "abs maxq" without arguments.
 3603 
 3604      Meaning:  Informative  message indicating current  status of
 3605                absentee queue  reservation for each  queue.  MMMM
 3606                is the mode, "auto" or "manual".
 3607 
 3608 
 3609 
 3610 admin_                          63            08/21/20     MR12.7^L
 3611 
 3612 
 3613      Action:   No operator action is required.
 3614 
 3615 
 3616                [admin_.pl1]
 3617                admin_:  abs:  qres:  error:  abs qres has invalid
 3618                value:  DDDD
 3619 
 3620 
 3621      Stream:   as (severity 1)
 3622 
 3623      Time:     In response to an operator command.
 3624 
 3625      Meaning:  An  invalid  qres  argument  was  detected  in  an
 3626                operator "abs qres" command.  The argument must be
 3627                "auto" or a positive decimal number.
 3628 
 3629      Action:   Enter a corrected command line.
 3630 
 3631 
 3632                [admin_.pl1]
 3633                admin_:  abs:  queue limits:  WW XX YY ZZ
 3634 
 3635 
 3636      Stream:   as (severity 1)
 3637 
 3638      Time:     In response to "abs qres" operator command.
 3639 
 3640      Meaning:  Informative  message indicating the  current queue
 3641                reservation limits.
 3642 
 3643      Action:   No operator action is required.
 3644 
 3645 
 3646                [admin_.pl1]
 3647                admin_:  abs:  Queue errors (*=dropped):
 3648                admin_:  abs:  FG 0 1 2 3 4
 3649                admin_:  abs:  TT VV WW XX YY ZZ
 3650                admin_:  abs:  * * * * * *
 3651 
 3652 
 3653 
 3654      Stream:   as (severity 1)
 3655 
 3656      Time:     In response to "abs queue" operator command.
 3657 
 3658      Meaning:  Displays the  errors for each queue  and indicates
 3659                which  one has  been dropped.   If none  have been
 3660                dropped, the  last line will not  be displayed nor
 3661                will the string "(*=dropped)"  appear in the first
 3662                line.
 3663 
 3664      Action:   Contact the system programming staff.
 3665 
 3666 
 3667 
 3668 admin_                          64            08/21/20     MR12.7^L
 3669 
 3670 
 3671 
 3672 
 3673                [admin_.pl1]
 3674                admin_:  abs:   release:  error:  Job  in absentee
 3675                slot X is not suspended.
 3676 
 3677 
 3678      Stream:   as (severity 1)
 3679 
 3680      Time:     In response to an operator command.
 3681 
 3682      Meaning:  The specified job running in absentee slot of absX
 3683                is not suspended so a release does not apply.
 3684 
 3685      Action:   Recheck job specifications and try again.
 3686 
 3687 
 3688                [admin_.pl1]
 3689                admin_:    abs:    release:    error:    Selection
 3690                arguments   matched  no   deferred  or   suspended
 3691                absentee requests.
 3692 
 3693 
 3694      Stream:   as (severity 1)
 3695 
 3696      Time:     In response to an operator command.
 3697 
 3698      Meaning:  No suspended or deferred  job was found to release
 3699                with  the arguments  supplied on  the abs  release
 3700                command line.
 3701 
 3702      Action:   Recheck job specifications and try again.
 3703 
 3704 
 3705                [admin_.pl1]
 3706                admin_:  abs:  resetting auto abs stop
 3707 
 3708 
 3709      Stream:   as (severity 1)
 3710 
 3711      Time:     In response to an operator abs stop command.
 3712 
 3713      Meaning:  An  abs stop  command overrides  an automatic  abs
 3714                stop that was set up by a down command.
 3715 
 3716      Action:   No operator action is required.
 3717 
 3718 
 3719                [admin_.pl1]
 3720                admin_:  abs:  start:  error:  absentee already up
 3721 
 3722 
 3723      Stream:   as (severity 1)
 3724 
 3725 
 3726 admin_                          65            08/21/20     MR12.7^L
 3727 
 3728 
 3729      Time:     In response to an operator abs start command.
 3730 
 3731      Meaning:  abs start was typed twice.  No action was taken on
 3732                the second issuance of the command.
 3733 
 3734      Action:   No operator action is required.
 3735 
 3736 
 3737                [admin_.pl1]
 3738                admin_:   abs:  start:   error:  absentee  not up.
 3739                cannot restart queue X
 3740 
 3741 
 3742      Stream:   as (severity 1)
 3743 
 3744      Time:     In response to an operator command.
 3745 
 3746      Meaning:  Cannot use the "abs start queue" command until the
 3747                absentee facility has been started.
 3748 
 3749      Action:   Issue the "abs start" command and try again.
 3750 
 3751 
 3752                [admin_.pl1]
 3753                admin_:  abs:  start:  error:  invalid queue to be
 3754                restarted X
 3755 
 3756 
 3757      Stream:   as (severity 1)
 3758 
 3759      Time:     In response to an operator command.
 3760 
 3761      Meaning:  An  invalid  queue  number  was  specified  in  an
 3762                operator "abs start queue"  command line.  It must
 3763                be between 1 and 4 inclusive.
 3764 
 3765      Action:   Enter a corrected command line.
 3766 
 3767 
 3768                [admin_.pl1]
 3769                admin_:  abs:  start:   error:  system coming down
 3770                soon:  no abs start
 3771 
 3772 
 3773      Stream:   as (severity 1)
 3774 
 3775      Time:     In response to an operator command.
 3776 
 3777      Meaning:  The system  is shutting down within  30 minutes so
 3778                the absentee facility will not be started.
 3779 
 3780      Action:   No operator action is required.
 3781 
 3782 
 3783 
 3784 admin_                          66            08/21/20     MR12.7^L
 3785 
 3786 
 3787 
 3788 
 3789                [admin_.pl1]
 3790                admin_:  abs:  stop:  error:   abs stop queue only
 3791                works after answering service startup
 3792 
 3793 
 3794      Stream:   as (severity 1)
 3795 
 3796      Time:     In response to an operator abs stop queue command.
 3797 
 3798      Meaning:  The answering service must complete initialization
 3799                before the "abs stop queue" command can be used.
 3800 
 3801      Action:   Allow  the system  to complete  initialization and
 3802                try again.
 3803 
 3804 
 3805                [admin_.pl1]
 3806                admin_:   abs:  stop:    error:  absentee  stop in
 3807                progress
 3808 
 3809 
 3810      Stream:   as (severity 1)
 3811 
 3812      Time:     In response to an operator command.
 3813 
 3814      Meaning:  An  abs start,  abs stop,  abs maxu,  abs maxq, or
 3815                down  command   was  issued  while   the  absentee
 3816                facility was in the process of shutting down.
 3817 
 3818      Action:   Wait for  the message that all  absentee processes
 3819                have run to completion, then reissue the command.
 3820 
 3821 
 3822 
 3823                [admin_.pl1]
 3824                admin_:  abs:  stop:  error:   invalid queue to be
 3825                stopped:  DDDD
 3826 
 3827 
 3828      Stream:   as (severity 1)
 3829 
 3830      Time:     In  response  to  an  operator  "abs  stop  queue"
 3831                command.
 3832 
 3833      Meaning:  The value  of the queue number was  not within the
 3834                values of 1 and 4, inclusive.
 3835 
 3836      Action:   Enter a corrected command line.
 3837 
 3838 
 3839                [admin_.pl1]
 3840 
 3841 
 3842 admin_                          67            08/21/20     MR12.7^L
 3843 
 3844 
 3845                admin_:   abs:  stop:   error:  missing  argument:
 3846                queue to be stopped
 3847 
 3848 
 3849      Stream:   as (severity 1)
 3850 
 3851      Time:     In  response  to  an  operator  "abs  stop  queue"
 3852                command.
 3853 
 3854      Meaning:  The "abs  stop queue" command was  entered without
 3855                supplying the number of the queue to be stopped.
 3856 
 3857      Action:   Enter a corrected command line.
 3858 
 3859 
 3860                [admin_.pl1]
 3861                admin_:   abs:   stop:   error:   unknown argument
 3862                SSSS
 3863 
 3864 
 3865      Stream:   as (severity 1)
 3866 
 3867      Time:     In response to an operator "abs stop" command.
 3868 
 3869      Meaning:  An  unknown argument,  SSSS, was  supplied to  the
 3870                "abs stop" command.
 3871 
 3872      Action:   Type "help abs" for details of the abs command and
 3873                try again.
 3874 
 3875 
 3876                [admin_.pl1]
 3877                admin_:  abs:   suspend:  error:  Job  in absentee
 3878                slot X is already suspended.
 3879 
 3880 
 3881      Stream:   as (severity 1)
 3882 
 3883      Time:     In response to an operator command.
 3884 
 3885      Meaning:  The specified job running in absentee slot of absX
 3886                is  already  suspended  and  cannot  be  suspended
 3887                again.
 3888 
 3889      Action:   Recheck job specifications and try again.
 3890 
 3891 
 3892                [admin_.pl1]
 3893                admin_:   abs:    Warning:   cpu  limits   are  in
 3894                seconds.   You just  set  queue  QQ limit  to LLLL
 3895                seconds.
 3896 
 3897 
 3898 
 3899 
 3900 admin_                          68            08/21/20     MR12.7^L
 3901 
 3902 
 3903      Stream:   as (severity 1)
 3904 
 3905      Time:     In  response  to   "abs  cpu_limit"  command  with
 3906                arguments.
 3907 
 3908      Meaning:  The  cpu_limit (LLLL)  for  queue  QQ is  below 60
 3909                seconds  which is  likely  to  be a  mistake.  The
 3910                value already given will be still be accepted.
 3911 
 3912      Action:   Reenter  the  command  with  corrected  values  if
 3913                originally incorrect.
 3914 
 3915 
 3916                [admin_.pl1]
 3917                admin_:  abs:  Zero errors on all absentee queues.
 3918 
 3919 
 3920      Stream:   as (severity 1)
 3921 
 3922      Time:     In response to "abs queue" operator command.
 3923 
 3924      Meaning:  Informative message which  indicates that no queue
 3925                has  been dropped and  no errors recorded  for any
 3926                queue.
 3927 
 3928      Action:   No operator action is required.
 3929 
 3930 
 3931                [admin_.pl1]
 3932                admin_:  bump:  USER.PROJECT bumped.
 3933 
 3934 
 3935      Stream:   as (severity 1)
 3936 
 3937      Time:     In  response  to  the  bump  command  or  a system
 3938                shutdown.
 3939 
 3940      Meaning:  The  specified user has  been notified that  he or
 3941                she must get off the  system.  If a grace time was
 3942                specified, the user is allowed that amount of time
 3943                to  logout.  Otherwise,  the user  is removed from
 3944                the system immediately.
 3945 
 3946      Action:   No operator action is required.
 3947 
 3948 
 3949                [admin_.pl1]
 3950                admin_:  COMMAND:  error:  Invalid FNP tag:  X
 3951 
 3952 
 3953      Stream:   as (severity 1)
 3954 
 3955 
 3956 
 3957 
 3958 admin_                          69            08/21/20     MR12.7^L
 3959 
 3960 
 3961      Time:     Response  to an operator  "load_fnp", "fdump_fnp",
 3962                "dump_fnp", "start_fnp", or "stop_fnp" command.
 3963 
 3964      Meaning:  The supplied  FNP tag was more  than one character
 3965                or was not between a-h inclusive.
 3966 
 3967      Action:   Enter a corrected command line.
 3968 
 3969 
 3970                [admin_.pl1]
 3971                admin_:  COMMAND:  error:  No FNP tag specified.
 3972 
 3973 
 3974      Stream:   as (severity 1)
 3975 
 3976      Time:     Response  to an operator  "load_fnp", "fdump_fnp",
 3977                "dump_fnp", "start_fnp", or "stop_fnp" command.
 3978 
 3979      Meaning:  The operator did not supply an FNP identifier.
 3980 
 3981      Action:   Enter a corrected command line.
 3982 
 3983 
 3984                [admin_.pl1]
 3985                admin_:    COMMAND:     error:    No   multiplexer
 3986                specified.
 3987 
 3988 
 3989      Stream:   as (severity 1)
 3990 
 3991      Time:     Response  to an  operator "load_mpx",  "dump_mpx",
 3992                "start_mpx", "shutdown_mpx" or "stop_mpx" command.
 3993 
 3994      Meaning:  The operator did not supply a multiplexer name.
 3995 
 3996      Action:   Enter a corrected command line.
 3997 
 3998 
 3999                [admin_.pl1]
 4000                admin_:  COMMAND:  ERROR_TABLE_MESSAGE
 4001 
 4002 
 4003      Stream:   as (severity 1)
 4004 
 4005      Time:     In response to operator command, COMMAND.
 4006 
 4007      Meaning:  The  ERROR_TABLE_MESSAGE error was  encounted when
 4008                processing the operator command, COMMAND.
 4009 
 4010      Action:   Type "help  COMMAND" for details of  the command's
 4011                usage.
 4012 
 4013 
 4014 
 4015 
 4016 admin_                          70            08/21/20     MR12.7^L
 4017 
 4018 
 4019 
 4020 
 4021                [admin_.pl1]
 4022                admin_:  COMMAND:  PERSON.PROJECT has "nobump"
 4023 
 4024 
 4025      Stream:   as (severity 1)
 4026 
 4027      Time:     System shutdown.
 4028 
 4029      Meaning:  The  PERSON.PROJECT user  cannot be  bumped by the
 4030                automatic  shutdown  or  in  response  to the stop
 4031                command.   The nobump  attribute is  normally only
 4032                used by system administrator users.
 4033 
 4034      Action:   Try  to contact  the user   to arrange  a time  to
 4035                actually shutdown.  If necessary,  the user can be
 4036                bumped by specifying the  channel name in the bump
 4037                command.  This  will only work if  the process has
 4038                not been  disconnected.  Otherwise, you  will have
 4039                to answer "yes" to the shutdown command.
 4040 
 4041 
 4042 
 4043                [admin_.pl1]
 4044                admin_:  down:  auto shutdown  will be at MM/DD/YY
 4045                HHMM.T
 4046 
 4047 
 4048      Stream:   as (severity 1)
 4049 
 4050      Time:     In  response to  an  operator  down command  or at
 4051                startup.
 4052 
 4053      Meaning:  This  is the  response  to  the down  command.  It
 4054                indicates  the scheduled   shutdown time.   A down
 4055                command is issued  automatically at system startup
 4056                time after  a crash; if  a down command  was given
 4057                before  the crash  occurred, and  the time  of the
 4058                scheduled shutdown is more  than 30 minutes in the
 4059                future.
 4060 
 4061      Action:   If  the value  shown  in  the message  is correct,
 4062                proceed.   If not  correct, reset  the shutdown by
 4063                typing down 0 and then try again.
 4064 
 4065 
 4066 
 4067                [admin_.pl1]
 4068                admin_:    down:   error:    no  system   shutdown
 4069                scheduled
 4070 
 4071 
 4072 
 4073 
 4074 admin_                          71            08/21/20     MR12.7^L
 4075 
 4076 
 4077      Stream:   as (severity 1)
 4078 
 4079      Time:     In response to operator entering, "down 0".
 4080 
 4081      Meaning:  The "down  0" command line  cancels a down  but no
 4082                system  shutdown  was  scheduled.   No  action was
 4083                taken.
 4084 
 4085      Action:   No operator action is required.
 4086 
 4087 
 4088                [admin_.pl1]
 4089                admin_:   down:  error:    uptime is  earlier than
 4090                downtime.
 4091 
 4092 
 4093      Stream:   as (severity 1)
 4094 
 4095      Time:     In response to an operator down command.
 4096 
 4097      Meaning:  The  operator  down  command  specifies  that  the
 4098                expected time that the system will be up is before
 4099                the time that it is  scheduled to be shutdown.  No
 4100                action was taken.
 4101 
 4102      Action:   Enter a corrected command line.
 4103 
 4104 
 4105                [admin_.pl1]
 4106                admin_:  down:  error:  XXX invalid clock time.
 4107 
 4108 
 4109      Stream:   as (severity 1)
 4110 
 4111      Time:     In response to an operator down command.
 4112 
 4113      Meaning:  The  time  arguments  of  a  down  command must be
 4114                specified in 4-digit time  or some form acceptable
 4115                to convert_date_to_binary_.  No  action was taken.
 4116                If the second time argument is an invalid time, it
 4117                is considered  part of the message.   This message
 4118                is  also displayed if  the first time  argument is
 4119                not in the future.
 4120 
 4121      Action:   Enter a corrected command line.
 4122 
 4123 
 4124                [admin_.pl1]
 4125                admin_:   down:  Next  shutdown from  DATE_TIME to
 4126                DATE_TIME1 REASON
 4127 
 4128 
 4129      Stream:   as (severity 1)
 4130 
 4131 
 4132 admin_                          72            08/21/20     MR12.7^L
 4133 
 4134 
 4135      Time:     Response to an operator "down" command.
 4136 
 4137      Meaning:  This  message   tells  when  the   next  scheduled
 4138                shutdown is.
 4139 
 4140      Action:   No operator action is required.
 4141 
 4142 
 4143                [admin_.pl1]
 4144                admin_:  down:  No shutdown is scheduled.
 4145 
 4146 
 4147      Stream:   as (severity 1)
 4148 
 4149      Time:     In response to an operator down command.
 4150 
 4151      Meaning:  The operator  issued a down  0 command to  reset a
 4152                scheduled  automatic  shutdown  when  none  was in
 4153                effect.  No action was taken on the command.
 4154 
 4155      Action:   No operator action is required.
 4156 
 4157 
 4158                [admin_.pl1]
 4159                admin_:   down:   resetting  previous  shutdown at
 4160                MM/DD/YY HHMM.T
 4161 
 4162 
 4163      Stream:   as (severity 1)
 4164 
 4165      Time:     In response to an operator down command.
 4166 
 4167      Meaning:  A  second down  command has  been issued  before a
 4168                previously issued down  command has been executed.
 4169                The  new shutdown time  is honored instead  of the
 4170                previous one.
 4171 
 4172      Action:   No operator action is required.
 4173 
 4174 
 4175                [admin_.pl1]
 4176                admin_:  dump_fnp:  error:  unknown argument AAAA
 4177 
 4178 
 4179      Stream:   as (severity 1)
 4180 
 4181      Time:     In response to an operator dump_fnp command.
 4182 
 4183      Meaning:  An unknown argument, AAAA,  was encountered in the
 4184                dump_fnp  command  line.    This  is  an  obsolete
 4185                command.  No action was taken.
 4186 
 4187 
 4188 
 4189 
 4190 admin_                          73            08/21/20     MR12.7^L
 4191 
 4192 
 4193      Action:   Type "help  dump_mpx" for details of  the dump_mpx
 4194                command and try again.
 4195 
 4196 
 4197 
 4198                [admin_.pl1]
 4199                admin_:  dump_mpx:  error:  unknown argument AAAA
 4200 
 4201 
 4202      Stream:   as (severity 1)
 4203 
 4204      Time:     In response to an operator dump_mpx command.
 4205 
 4206      Meaning:  An unknown argument, AAAA,  was encountered in the
 4207                dump_mpx command line.  No action was taken.
 4208 
 4209      Action:   Type "help  dump_mpx" for details of  the dump_mpx
 4210                command and try again.
 4211 
 4212 
 4213 
 4214                [admin_.pl1]
 4215                admin_:  ERROR_MESSAGE SYSDIR>absentee_user_table
 4216 
 4217 
 4218      Stream:   as (severity 1)
 4219 
 4220      Time:     When operator entered abs command.
 4221 
 4222      Meaning:  The ERROR_MESSAGE gives reason  why system was not
 4223                able to find or  access the absentee_user_table in
 4224                the  SYSDIR directory.   Execution of  the command
 4225                was not completed.
 4226 
 4227      Action:   %inform
 4228 
 4229 
 4230                [admin_.pl1]
 4231                admin_:  ERROR_MESSAGE SYSDIR>answer_table
 4232 
 4233 
 4234      Stream:   as (severity 2)
 4235 
 4236      Time:     In  response  to  operator  commands  that require
 4237                access to the system answer_table.
 4238 
 4239      Meaning:  The ERROR_MESSAGE gives reason  why system was not
 4240                able  to find  or access  the answer_table  in the
 4241                SYSDIR  directory.  Execution  of the  command was
 4242                not completed.
 4243 
 4244      Action:   Contact the system programming staff.
 4245 
 4246 
 4247 
 4248 admin_                          74            08/21/20     MR12.7^L
 4249 
 4250 
 4251 
 4252 
 4253                [admin_.pl1]
 4254                admin_:  ERROR_MESSAGE SYSDIR>cdt
 4255 
 4256 
 4257      Stream:   as (severity 2)
 4258 
 4259      Time:     In  response  to  operator  commands  that require
 4260                access to the system cdt.
 4261 
 4262      Meaning:  The ERROR_MESSAGE gives reason  why system was not
 4263                able  to find  or access   the cdt  in the  SYSDIR
 4264                directory.   Execution  of  the  command  was  not
 4265                completed.
 4266 
 4267      Action:   Contact the system programming staff.
 4268 
 4269 
 4270                [admin_.pl1]
 4271                admin_:  ERROR_MESSAGE SYSDIR>installation_parms
 4272 
 4273 
 4274      Stream:   as (severity 2)
 4275 
 4276      Time:     In  response  to  operator  commands  that require
 4277                access to the system installation_parms.
 4278 
 4279      Meaning:  The ERROR_MESSAGE gives reason  why system was not
 4280                able to  find or access the  installation_parms in
 4281                the  SYSDIR directory.   Execution of  the command
 4282                was not completed.
 4283 
 4284      Action:   Contact the system programming staff.
 4285 
 4286 
 4287                [admin_.pl1]
 4288                admin_:  ERROR_MESSAGE SYSDIR>whotab
 4289 
 4290 
 4291      Stream:   as (severity 2)
 4292 
 4293      Time:     In  response  to  operator  commands  that require
 4294                access to the system whotab.
 4295 
 4296      Meaning:  The ERROR_MESSAGE gives reason  why system was not
 4297                able to  find or access  the whotab in  the SYSDIR
 4298                directory.   Execution  of  the  command  was  not
 4299                completed.
 4300 
 4301      Action:   Contact the system programming staff.
 4302 
 4303 
 4304 
 4305 
 4306 admin_                          75            08/21/20     MR12.7^L
 4307 
 4308 
 4309 
 4310 
 4311                [admin_.pl1]
 4312                admin_:  fdump_fnp:  error:  unknown argument AAAA
 4313 
 4314 
 4315      Stream:   as (severity 1)
 4316 
 4317      Time:     In response to an operator fdump_fnp command.
 4318 
 4319      Meaning:  An unknown argument, AAAA,  was encountered in the
 4320                fdump_fnp command.   This is an  obsolete command.
 4321                No action was taken.
 4322 
 4323      Action:   Type "help  dump_mpx" for details of  the dump_mpx
 4324                command and try again.
 4325 
 4326 
 4327 
 4328                [admin_.pl1]
 4329                admin_:  load_fnp:  unknown argument AAAA
 4330 
 4331 
 4332      Stream:   as (severity 1)
 4333 
 4334      Time:     In response to an operator load_fnp command.
 4335 
 4336      Meaning:  An unknown argument, AAAA,  was encountered in the
 4337                load_fnp  command  line.    This  is  an  obsolete
 4338                command.  No action was taken.
 4339 
 4340      Action:   Type "help  load_mpx" for details of  the load_mpx
 4341                command and try again.
 4342 
 4343 
 4344 
 4345                [admin_.pl1]
 4346                admin_:  load_mpx:  error:  unknown argument AAAA
 4347 
 4348 
 4349      Stream:   as (severity 1)
 4350 
 4351      Time:     In response to an operator load_mpx command.
 4352 
 4353      Meaning:  An unknown argument, AAAA,  was encountered in the
 4354                load_mpx command line.  No action was taken.
 4355 
 4356      Action:   Type "help  load_mpx" for details of  the load_mpx
 4357                command and try again.
 4358 
 4359 
 4360 
 4361 
 4362 
 4363 
 4364 admin_                          76            08/21/20     MR12.7^L
 4365 
 4366 
 4367 
 4368 
 4369                [admin_.pl1]
 4370                admin_:  load_mpx:  error:  unknown argument AAAA
 4371 
 4372 
 4373      Stream:   as (severity 1)
 4374 
 4375      Time:     In response to an operator load_mpx command.
 4376 
 4377      Meaning:  An unknown argument, AAAA,  was encountered in the
 4378                load_mpx command line.  No action was taken.
 4379 
 4380      Action:   Type  "help  load_mpx"  for  use  of  the load_mpx
 4381                command and try again.
 4382 
 4383 
 4384                [admin_.pl1]
 4385                admin_:  log:  MESSAGE
 4386 
 4387 
 4388      Stream:   as (severity 0)
 4389 
 4390      Time:     While system is running.
 4391 
 4392      Meaning:  The log command simply enters its arguments in the
 4393                system log.  It is  occasionally used by operators
 4394                and system programmers to record events.
 4395 
 4396      Action:   No operator action is required.
 4397 
 4398 
 4399                [admin_.pl1]
 4400                admin_:   login:   Entry  not  found.   No  MC ACS
 4401                segment for the source SSSS.
 4402 
 4403 
 4404      Stream:   as (severity 1)
 4405 
 4406      Time:     In response to operator login command.
 4407 
 4408      Meaning:  An MC  ACS was not found  in >sc1>mc_acs directory
 4409                for the source identifier, SSSS.
 4410 
 4411      Action:   Contact the system programming staff.
 4412 
 4413 
 4414                [admin_.pl1]
 4415                admin_:     login:     error:     Usage:     login
 4416                Person.Project SOURCE {-control_args}
 4417 
 4418 
 4419      Stream:   as (severity 1)
 4420 
 4421 
 4422 admin_                          77            08/21/20     MR12.7^L
 4423 
 4424 
 4425      Time:     In  response  to  operator  login  command with no
 4426                arguments.
 4427 
 4428      Meaning:  Informative  message to   operator when  the login
 4429                command was entered without arguments.
 4430 
 4431      Action:   Also  type  "help  login"  for  further details of
 4432                command line syntax.
 4433 
 4434 
 4435                [admin_.pl1]
 4436                admin_:   login:   ERROR_TABLE_MESSAGE  Login  not
 4437                permitted for message coordinator source SSSS.
 4438 
 4439 
 4440      Stream:   as (severity 1)
 4441 
 4442      Time:     In response to operator login command.
 4443 
 4444      Meaning:  The  error identified  by ERROR_TABLE_MESSAGE  was
 4445                encountered  attempting  to  check  the  access to
 4446                login the daemon whose source identifier is SSSS.
 4447 
 4448 
 4449 
 4450                [admin_.pl1]
 4451                admin_:     logout:    error:     Usage:    logout
 4452                Person.Project {SOURCE}
 4453 
 4454 
 4455      Stream:   as (severity 1)
 4456 
 4457      Time:     In  response  to   operator  logout  command  when
 4458                entered without arguments.
 4459 
 4460      Meaning:  Informative message indicating usage of the logout
 4461                command.
 4462 
 4463      Action:   Type "help logout" for  further details of command
 4464                usage.
 4465 
 4466 
 4467                [admin_.pl1]
 4468                admin_:  maxu:  (MMMM):  UUUU (DDDD normal users)
 4469 
 4470 
 4471 
 4472      Stream:   as (severity 1)
 4473 
 4474      Time:     When operator entered "maxu" command.
 4475 
 4476      Meaning:  This  is  an  informative  message  indicating the
 4477                current  values manipulated  by the  maxu command.
 4478 
 4479 
 4480 admin_                          78            08/21/20     MR12.7^L
 4481 
 4482 
 4483                MMMM is the mode, "auto"  or "level".  UUUU is the
 4484                load units  in tenths.  DDDD is the  load units in
 4485                whole numbers.
 4486 
 4487      Action:   No operator action is required.
 4488 
 4489 
 4490                [admin_.pl1]
 4491                admin_:  maxu:   Warning:  maxunits are  in tenths
 4492                of load units.
 4493                You just set maxu to UUUU, or DDDD normal users.
 4494 
 4495 
 4496 
 4497      Stream:   as (severity 1)
 4498 
 4499      Time:     When  operator entered  a maxu  command line  that
 4500                specified < 200 load units or 20 normal users.
 4501 
 4502      Meaning:  This message is a warning  to the operator that he
 4503                may have made a mistake  in setting the load units
 4504                of the  system.  A normal system is  not likely to
 4505                set its maximum load units to less than 200.
 4506 
 4507      Action:   Take corrective  action (reenter the  command with
 4508                corrected arguments).
 4509 
 4510 
 4511 
 4512                [admin_.pl1]
 4513                admin_:  maxunits:  error:   XXX invalid value for
 4514                maxunits
 4515 
 4516 
 4517      Stream:   as (severity 1)
 4518 
 4519      Time:     In response to an operator maxunits command.
 4520 
 4521      Meaning:  The  argument of  the maxunits  command was  not a
 4522                number, or  was zero, or negative.   No action was
 4523                taken.
 4524 
 4525      Action:   Enter a corrected command line.
 4526 
 4527 
 4528                [admin_.pl1]
 4529                admin_:  rcp:  error:  unknown rcp command RRRR
 4530 
 4531 
 4532      Stream:   as (severity 1)
 4533 
 4534      Time:     In response to an operator rcp command.
 4535 
 4536 
 4537 
 4538 admin_                          79            08/21/20     MR12.7^L
 4539 
 4540 
 4541      Meaning:  The operator  has entered an unknown  rcp operator
 4542                on the command line.
 4543 
 4544      Action:   Type "help rcp" for further details on rcp command
 4545                usage.
 4546 
 4547 
 4548                [admin_.pl1]
 4549                admin_:  shift:  error:  CCCC invalid clock time.
 4550 
 4551 
 4552      Stream:   as (severity 1)
 4553 
 4554      Time:     In response to an operator shift command.
 4555 
 4556      Meaning:  The time  argument of the  shift command is  not a
 4557                valid      clock      time      acceptable      to
 4558                convert_date_to_binary_.
 4559 
 4560      Action:   Enter a corrected command line.
 4561 
 4562 
 4563                [admin_.pl1]
 4564                admin_:   shift:  error:   CCCC is  not within the
 4565                next week.
 4566 
 4567 
 4568      Stream:   as (severity 1)
 4569 
 4570      Time:     In response to an operator shift command.
 4571 
 4572      Meaning:  The  time  argument  of  the  shift command cannot
 4573                specify a  time stamp that  is over a  week in the
 4574                future.
 4575 
 4576      Action:   Enter a corrected command line.
 4577 
 4578 
 4579                [admin_.pl1]
 4580                admin_:  shift:  error:  XXXX is not a legal shift
 4581                number.
 4582 
 4583 
 4584      Stream:   as (severity 1)
 4585 
 4586      Time:     In response to an operator shift command.
 4587 
 4588      Meaning:  A shift  argument to the  shift command was  not a
 4589                valid decimal number between 1 and 6 inclusive.
 4590 
 4591      Action:   Enter a corrected command line.
 4592 
 4593 
 4594 
 4595 
 4596 admin_                          80            08/21/20     MR12.7^L
 4597 
 4598 
 4599 
 4600 
 4601                [admin_.pl1]
 4602                admin_:  shift:  N until DATE_TIME
 4603 
 4604 
 4605      Stream:   as (severity 1)
 4606 
 4607      Time:     response to an operator "shift" command.
 4608 
 4609      Meaning:  The  operator has  issued the  shift command.   If
 4610                issued  with no  arguments this  command types the
 4611                current  setting.  If  issued with  arguments, the
 4612                command changes the shift and types the new value.
 4613 
 4614      Action:   No operator action is required.
 4615 
 4616 
 4617                [admin_.pl1]
 4618                admin_:   shutdown_mpx:  error:   unknown argument
 4619                AAAA
 4620 
 4621 
 4622      Stream:   as (severity 1)
 4623 
 4624      Time:     In response to an operator shutdown_mpx command.
 4625 
 4626      Meaning:  An unknown argument, AAAA,  was encountered in the
 4627                shutdown_mpx command line.  No action was taken.
 4628 
 4629      Action:   The  shutdown_mpx  command  is  the  same  as  the
 4630                dump_mpx command  except that no dump  is created.
 4631                Type "help dump_mpx" for command usage details and
 4632                try again.
 4633 
 4634 
 4635 
 4636                [admin_.pl1]
 4637                admin_:  stop:   All users are out.   You may shut
 4638                down.
 4639 
 4640 
 4641      Stream:   as (severity 1)
 4642 
 4643      Time:     System shutdown.
 4644 
 4645      Meaning:  This is  the response to  the stop command  if all
 4646                users have been logged out.  This message provides
 4647                a  quick  check  of  whether  all  users have been
 4648                bumped since  it does not adversely  affect system
 4649                operation to issue the stop command repeatedly.
 4650 
 4651      Action:   Proceed with the shutdown.
 4652 
 4653 
 4654 admin_                          81            08/21/20     MR12.7^L
 4655 
 4656 
 4657 
 4658 
 4659                [admin_.pl1]
 4660                admin_:   stop:  all  users have  been given  XXXX
 4661                minutes to logout
 4662 
 4663 
 4664      Stream:   as (severity 1)
 4665 
 4666      Time:     System shutdown.
 4667 
 4668      Meaning:  A  stop command,  either manual  or automatic, has
 4669                been initiated.   All users have been  warned that
 4670                they  have XXXX minutes  to finish up  and logout.
 4671                After  XXXX  minutes,  all  users  will  be bumped
 4672                except those with the nobump attribute.  The login
 4673                word has  been set so  that no more  users may log
 4674                in.  To  cancel this shutdown, issue  a word login
 4675                command and an unbump * * command.
 4676 
 4677      Action:   No operator action is required.
 4678 
 4679 
 4680                [admin_.pl1]
 4681                admin_:  stop:  auto abs stop
 4682 
 4683 
 4684      Stream:   as (severity 1)
 4685 
 4686      Time:     While system is running.
 4687 
 4688      Meaning:  It is  30 minutes before an automatic  stop, so an
 4689                automatic abs stop command  is being issued.  This
 4690                is the  result of a previous  down command.  Refer
 4691                also to the stop command description.
 4692 
 4693      Action:   No operator action is required.
 4694 
 4695 
 4696                [admin_.pl1]
 4697                admin_:  stop:  Automatic shutdown
 4698 
 4699 
 4700      Stream:   as (severity 1)
 4701 
 4702      Time:     System shutdown.
 4703 
 4704      Meaning:  A  down command  issued earlier  has taken effect.
 4705                An automatic stop command  is executed.  All users
 4706                are bumped in three minutes.
 4707 
 4708      Action:   Prepare to shut down the system.
 4709 
 4710 
 4711 
 4712 admin_                          82            08/21/20     MR12.7^L
 4713 
 4714 
 4715 
 4716 
 4717                [admin_.pl1]
 4718                admin_:  stop:   error:  no arguments  are allowed
 4719                for "stop"
 4720 
 4721 
 4722      Stream:   as (severity 1)
 4723 
 4724      Time:     In response to an operator stop command.
 4725 
 4726      Meaning:  The  operator has  given an  argument to  the stop
 4727                command.  No arguments are allowed.  No action was
 4728                taken.
 4729 
 4730      Action:   If abs stop was meant, type that command.  If stop
 4731                was  meant, type  that command  instead.  If "down
 4732                ...."  was meant, type in that command.
 4733 
 4734 
 4735 
 4736                [admin_.pl1]
 4737                admin_:  stop:   There were no active  users to be
 4738                bumped.
 4739 
 4740 
 4741      Stream:   as (severity 1)
 4742 
 4743      Time:     System shutdown.
 4744 
 4745      Meaning:  The  system did  not find  any active  users to be
 4746                bumped.
 4747 
 4748      Action:   No operator action is required.
 4749 
 4750 
 4751                [admin_.pl1]
 4752                admin_:  stop_fnp:  error:  unknown argument AAAA
 4753 
 4754 
 4755      Stream:   as (severity 1)
 4756 
 4757      Time:     In response to an operator stop_mpx command.
 4758 
 4759      Meaning:  An unknown argument, AAAA,  was encountered in the
 4760                stop_fnp  command  line.    This  is  an  obsolete
 4761                command.  No action was taken.
 4762 
 4763      Action:   Type "help  stop_mpx" for details of  the stop_mpx
 4764                command and try again.
 4765 
 4766 
 4767 
 4768 
 4769 
 4770 admin_                          83            08/21/20     MR12.7^L
 4771 
 4772 
 4773 
 4774 
 4775                [admin_.pl1]
 4776                admin_:  stop_mpx:  error:  unknown argument AAAA
 4777 
 4778 
 4779      Stream:   as (severity 1)
 4780 
 4781      Time:     In response to an operator stop_mpx command.
 4782 
 4783      Meaning:  An unknown argument, AAAA,  was encountered in the
 4784                stop_mpx command line.  No action was taken.
 4785 
 4786      Action:   Type "help  stop_mpx" for details of  the stop_mpx
 4787                command and try again.
 4788 
 4789 
 4790 
 4791                [admin_.pl1]
 4792                admin_:      warn:     error:      Usage:     warn
 4793                Person.Project MESSAGE
 4794 
 4795 
 4796      Stream:   as (severity 1)
 4797 
 4798      Time:     In  response to  an operator  warn command without
 4799                any arguments.
 4800 
 4801      Meaning:  Informative message  indicating usage of  the warn
 4802                command.
 4803 
 4804      Action:   Also,  type "help warn"  for more details  on warn
 4805                command usage.
 4806 
 4807 
 4808                [admin_.pl1]
 4809                admin_:  warn:  NAME.PROJ has "no_warning"
 4810 
 4811 
 4812      Stream:   as (severity 1)
 4813 
 4814      Time:     Response to operator warn command.
 4815 
 4816      Meaning:  This  is the  response to  the command  "warn NAME
 4817                PROJ  Message..."  if  the user  has specified the
 4818                -no_warning argument at login.  The message is not
 4819                sent to the user.
 4820 
 4821      Action:   Attempt to contact the user by other means.
 4822 
 4823 
 4824                [admin_.pl1]
 4825                admin_:  warn:  NAME.PROJ not found.
 4826 
 4827 
 4828 admin_                          84            08/21/20     MR12.7^L
 4829 
 4830 
 4831      Stream:   as (severity 1)
 4832 
 4833      Time:     In response to an operator warn command.
 4834 
 4835      Meaning:  The  warn  command  was  issued  for a nonexistent
 4836                user.  No action was taken.
 4837 
 4838      Action:   The  user is  probably not  logged in.   Check the
 4839                spelling  of the   name.Enter a  corrected command
 4840                line.
 4841 
 4842 
 4843 
 4844                [admin_.pl1]
 4845                admin_:   warn:   USER.PROJ  not  connected  to  a
 4846                channel
 4847 
 4848 
 4849      Stream:   as (sevreity1)
 4850 
 4851      Time:     Response to operator warn command.
 4852 
 4853      Meaning:  This  is the  response to  the command  "warn NAME
 4854                PROJ Message" if the  pointer to the channel table
 4855                entry in  the user table entry for  the named user
 4856                (ute.cdtep) is not set (null).  The message cannot
 4857                be sent to the user.
 4858 
 4859      Action:   Attempt to contact the user by other means.
 4860 
 4861 
 4862                [admin_.pl1]
 4863                admin_:   word:   length  of  login-word  must not
 4864                exceed 8 characters
 4865 
 4866 
 4867      Stream:   as (severity 1)
 4868 
 4869      Time:     In response to an operator word command.
 4870 
 4871      Meaning:  The operator tried to set  the login word with the
 4872                word command but the  first argument was too long.
 4873                No action was taken on the command.
 4874 
 4875      Action:   Enter a corrected command line.
 4876 
 4877 
 4878                [admin_.pl1]
 4879                admin_:  word:  message  truncated; maximum length
 4880                is CCCC characters
 4881 
 4882 
 4883      Stream:   as (severity 1)
 4884 
 4885 
 4886 admin_                          85            08/21/20     MR12.7^L
 4887 
 4888 
 4889      Time:     In response to an operator word command.
 4890 
 4891      Meaning:  The operator issued the  command "word XXXX TEXT".
 4892                The message TEXT was too long to fit in the dialup
 4893                message buffer.  The login  word has been changed,
 4894                and the  dialup message has been set  to the first
 4895                CCCC characters of the given message.
 4896 
 4897      Action:   Reword   the    message   to   fit    within   the
 4898                CCCC-character limit, and retype the command.
 4899 
 4900 
 4901 
 4902                [admin_.pl1]
 4903                admin_:  word:  TYPE message:  TEXT
 4904 
 4905 
 4906      Stream:   as (severity 1)
 4907 
 4908      Time:     In response to an operator word command.
 4909 
 4910      Meaning:  The operator issued the  command "word XXXX TEXT".
 4911                The  login word  was set  to XXXX,  and a  special
 4912                buffer was loaded with the message TEXT so that it
 4913                is typed  out whenever a user dials  up.  The type
 4914                of  system session is  TYPE; this may  be special,
 4915                normal, or shutdown.
 4916 
 4917      Action:   Check the message for accuracy.
 4918 
 4919 
 4920                [admin_.pl1]
 4921                admin_:  word:  XXXX is a reserved word.
 4922 
 4923 
 4924      Stream:   as (severity 1)
 4925 
 4926      Time:     In response to an operator word command.
 4927 
 4928      Meaning:  The  operator attempted  to set  the system  login
 4929                word  to enter,  enterp, e,  ep, dial,  or d.   No
 4930                action was taken.
 4931 
 4932      Action:   Pick another word and type it in.
 4933 
 4934 
 4935                [admin_.pl1]
 4936                admin_:  word:  XXXX; TYPE message:  TEXT
 4937 
 4938 
 4939      Stream:   as (severity 1)
 4940 
 4941      Time:     In response to an operator word command.
 4942 
 4943 
 4944 admin_                          86            08/21/20     MR12.7^L
 4945 
 4946 
 4947      Meaning:  The  operator  issued  the  word  command  with no
 4948                arguments, and the current values were typed.  The
 4949                login word  is XXXX, the message is  TEXT, and the
 4950                type of session is TYPE.  The TEXT is displayed as
 4951                the   first  line   of  the   greeting  banner  to
 4952                interactive users making the  banner 3 lines long.
 4953                If TEXT is "" (NO  MESSAGE), then nothing is added
 4954                to the normal 2 line greeting banner.
 4955 
 4956      Action:   Check the word, type, and message for accuracy.
 4957 
 4958 
 4959                [salv_dir_checker_.pl1]
 4960                ADUIT  (salv_dir_checker_):  GRANTED  modification
 4961                of security out-of-service ADDED_INFO
 4962 
 4963 
 4964      Stream:   $access_audit
 4965 
 4966      Time:     Salvaging
 4967 
 4968      Meaning:  The security-out-of-service switch has been set on
 4969                a directory  because of an AIM  error.  The access
 4970                class  of a branch  was not equal  to that of  the
 4971                containing directory,  or the access class  in the
 4972                directory's  branch was  not equal  to the  access
 4973                class stored in its header.
 4974 
 4975      Action:   Contact the system programming staff._ssa
 4976 
 4977 
 4978                [announce_chwm.pl1]
 4979                announce_chwm:  WWW pages wired, UUU pages usable.
 4980 
 4981 
 4982      Stream:   BOS Typewriter.
 4983 
 4984      Time:     System Intialization.
 4985 
 4986      Meaning:  This message is produced when the CHWM paramter is
 4987                specified  on the  PARM CONFIG  card.  WWW  is the
 4988                number of  wired pages in collection  one.  UUU is
 4989                the  number  of   available  main  memory  frames,
 4990                including those  occupied by wired pages,  but not
 4991                those occupied by unpaged segments.
 4992 
 4993      Action:   No operator action is required.
 4994 
 4995 
 4996                [announce_chwm.pl1]
 4997                announce_chwm:  WWW.  pages used of XXX.  in wired
 4998                environment.
 4999 
 5000 
 5001 
 5002 announce_chwm                   87            08/21/20     MR12.7^L
 5003 
 5004 
 5005      Stream:   BOS Typewriter.
 5006 
 5007      Time:     System Intialization.
 5008 
 5009      Meaning:  This message  is produced when the  CHWM parameter
 5010                is specified on the PARM  CONFIG card.  WWW is the
 5011                number of pages of memory which remain unused (out
 5012                of  a maximum  of XXX)  after all  the segments in
 5013                collection  one  have  been  loaded,  and  all the
 5014                segments constructed  by collection one  have been
 5015                created.
 5016 
 5017      Action:   No operator action is required.
 5018 
 5019 
 5020                [announce_chwm.pl1]
 5021                announce_chwm:   WWW.   words  used  of  XXX.   in
 5022                int_unpaged_page_tables.
 5023 
 5024 
 5025      Stream:   BOS Typewriter.
 5026 
 5027      Time:     System Intialization.
 5028 
 5029      Meaning:  This message  is produced when the  CHWM parameter
 5030                is specified on the PARM  CONFIG card.  WWW is the
 5031                number  of  words  of  the  XXX  word long segment
 5032                int_unpaged_page_tables  used to hold  page tables
 5033                for temporary collection 1 segments.
 5034 
 5035      Action:   No operator action is required.
 5036 
 5037 
 5038                [announce_chwm.pl1]
 5039                announce_chwm:   WWW.   words  used  of  XXX.   in
 5040                unpaged_page_tables.
 5041 
 5042 
 5043      Stream:   BOS Typewriter.
 5044 
 5045      Time:     System Intialization.
 5046 
 5047      Meaning:  This message  is produced when the  CHWM parameter
 5048                is specified on the PARM  CONFIG card.  WWW is the
 5049                number  of  words  of  the  XXX  word long segment
 5050                unpaged_page_tables used  to hold page  tables for
 5051                permanent "unpaged" segments.
 5052 
 5053      Action:   No operator action is required.
 5054 
 5055 
 5056                [append.pl1]
 5057 
 5058 
 5059 
 5060 append                          88            08/21/20     MR12.7^L
 5061 
 5062 
 5063                append:    error  from   delete_vtoce  for   PATH:
 5064                ERROR_MESSAGE
 5065 
 5066 
 5067      Stream:   Logged in SYSERR log.
 5068 
 5069      Time:     While system is running.
 5070 
 5071      Meaning:  While  deleting  a  VTOC  entry  to  clean  up  an
 5072                unsuccessful attempt  to create an  branch, append
 5073                got an error.  This indicates a logic error in the
 5074                supervisor, or CPU or memory hardware problems.
 5075 
 5076      Action:   Note for system programmer action.
 5077 
 5078 
 5079                [append.pl1]
 5080                append:  error from hash$out for PATH:  ERROR_CODE
 5081 
 5082 
 5083      Stream:   Logged in SYSERR log.
 5084 
 5085      Time:     While system is running.
 5086 
 5087      Meaning:  While removing a name  to clean up an unsuccessful
 5088                attempt to  create a branch, append  got an error.
 5089                This indicates a logic error in the supervisor, or
 5090                CPU or memory hardware problems.
 5091 
 5092      Action:   Note for system programmer action.
 5093 
 5094 
 5095                [append.pl1]
 5096                append:    error  from   makeunknown_  for   PATH:
 5097                ERROR_CODE
 5098 
 5099 
 5100      Stream:   Logged in SYSERR log.
 5101 
 5102      Time:     While system is running.
 5103 
 5104      Meaning:  Append made  the new directory PATH  unknown after
 5105                initializing  its  header.    While  doing  so  it
 5106                encountered  an  error.   This  indicates  a logic
 5107                error in the supervisor, or CPU or memory hardware
 5108                problems.
 5109 
 5110      Action:   Note for system programmer action.
 5111 
 5112 
 5113                [append.pl1]
 5114                append:   makeunknown_  err  after  quota  err for
 5115                PATH:  ERROR_CODE
 5116 
 5117 
 5118 append                          89            08/21/20     MR12.7^L
 5119 
 5120 
 5121      Stream:   Logged in SYSERR log.
 5122 
 5123      Time:     While system is running.
 5124 
 5125      Meaning:  During  the creation  of a  new directory,  append
 5126                encountered an error moving quota.  While cleaning
 5127                up   from   this   error   a   further  error  was
 5128                encountered.   The  system  continues  to operate.
 5129                This indicates a logic error in the supervisor, or
 5130                CPU or memory hardware problems.
 5131 
 5132      Action:   Note for system programmer action.
 5133 
 5134 
 5135                [as_add_admin_acl_.pl1]
 5136                as_add_admin_acl_:  ERROR_MESSAGE.   Could not add
 5137                PGID to ACL of PATH.
 5138 
 5139 
 5140      Stream:   as (severity2)
 5141 
 5142      Time:     Answering  Service  initialization,  or  while the
 5143                system is running.
 5144 
 5145      Meaning:  An  error  occurred  while  trying  to rebuild the
 5146                access   control  list    (ACL)  on   PATH  where:
 5147                ERROR_MESSAGE is an error_table_ message
 5148                PGID is a process group id
 5149                PATH is a full pathname
 5150 
 5151      Action:   Manually   give  PGID   read  access   (or  status
 5152                permission) to PATH.
 5153 
 5154 
 5155                [as_add_admin_acl_.pl1]
 5156                as_add_admin_acl_:  ERROR_MESSAGE.   Could not add
 5157                to ACL of PATH.
 5158 
 5159 
 5160      Stream:   as (severity2)
 5161 
 5162      Time:     Answering  Service  initialization,  or  while the
 5163                system is running.
 5164 
 5165      Meaning:  Some  fatal error   occurred while  rebuilding the
 5166                access control list  (ACL) of PATH.  ERROR_MESSAGE
 5167                is  an error_table_ message  and PATH is  the full
 5168                pathname of a segment or a directory.
 5169 
 5170      Action:   Contact   the  system   programming  staff.    The
 5171                operation that caused the error must be determined
 5172                and the operation repeated after correction.
 5173 
 5174 
 5175 
 5176 as_add_admin_acl_               90            08/21/20     MR12.7^L
 5177 
 5178 
 5179 
 5180 
 5181                [as_dump_.pl1]
 5182                as_dump_:   Answering  service   dump  created  in
 5183                segment >sc1>asdump.-.MM/DD/YY-HHMM
 5184 
 5185 
 5186      Stream:   as (severity1)
 5187 
 5188      Time:     While system is running.
 5189 
 5190      Meaning:  Some program  has encountered an  unexpected fault
 5191                and  has  called  for  a  dump  of  the  Answering
 5192                Service.  This segment is automatically dprinted.
 5193 
 5194      Action:   No operator action is required.
 5195 
 5196 
 5197                [as_dump_.pl1]
 5198                as_dump_:  Cannot attach I/O switch.  No dump NAME
 5199 
 5200 
 5201      Stream:   as (severity2)
 5202 
 5203      Time:     While system is running.
 5204 
 5205      Meaning:  An  error  occurred  while  dumping.   No dump was
 5206                taken.
 5207 
 5208      Action:   Contact the system programming staff.
 5209 
 5210 
 5211                [as_dump_.pl1]
 5212                as_dump_:   Cannot  obtain  quota,  dump  aborted.
 5213                NAME
 5214 
 5215 
 5216      Stream:   as (severity2)
 5217 
 5218      Time:     While system is running.
 5219 
 5220      Meaning:  An  error  occurred  while  dumping.   No dump was
 5221                taken.
 5222 
 5223      Action:   Contact the system programming staff.
 5224 
 5225 
 5226                [as_dump_.pl1]
 5227                as_dump_:  CONDITION while dumping.  Dump aborted
 5228 
 5229 
 5230      Stream:   as (severity1)
 5231 
 5232 
 5233 
 5234 as_dump_                        91            08/21/20     MR12.7^L
 5235 
 5236 
 5237      Time:     While system is running.
 5238 
 5239      Meaning:  During the attempt to perform an Answering Service
 5240                dump, some unexpected fault occurred.  The dump is
 5241                stopped and the system tries to continue.
 5242 
 5243      Action:   Notify the system programming staff.
 5244 
 5245 
 5246                [as_dump_.pl1]
 5247                as_dump_:     ERROR_MESSAGE.      Cannot    attach
 5248                as_dump_stream_    to     FILENAME.     No    dump
 5249                asdump.MM/DD/YY-HHMM
 5250 
 5251 
 5252      Stream:   as (severity1)
 5253 
 5254      Time:     While system is running.
 5255 
 5256      Meaning:  The  Answering  Service  dump  program  could  not
 5257                attach a file for the Answering Service dump.  The
 5258                dump will abort, and the system will continue.
 5259 
 5260      Action:   Contact the system programming staff.
 5261 
 5262 
 5263                [as_dump_.pl1]
 5264                as_dump_:  ERROR_MESSAGE.  Cannot  obtain quota of
 5265                >sc1, dump aborted.  DUMPID
 5266 
 5267 
 5268      Stream:   as (severity2)
 5269 
 5270      Time:     While system is running.
 5271 
 5272      Meaning:  An  error  occurred  while  dumping.   No dump was
 5273                taken.
 5274 
 5275      Action:   Contact the system programming staff.
 5276 
 5277 
 5278                [as_dump_.pl1]
 5279                as_dump_:   Message  coordinator  dump  created in
 5280                segment >sc1>asdump.-.MM/DD/YY-HHMM
 5281 
 5282 
 5283      Stream:   BOS Typewriter.
 5284 
 5285      Time:     While system is running.
 5286 
 5287      Meaning:  Some program  has encountered an  unexpected fault
 5288                and  has   called  for  a  dump   of  the  message
 5289 
 5290 
 5291 
 5292 as_dump_                        92            08/21/20     MR12.7^L
 5293 
 5294 
 5295                coordinator.    This   segment   is  automatically
 5296                dprinted.
 5297 
 5298      Action:   No operator action is required.
 5299 
 5300 
 5301                [as_dump_.pl1]
 5302                as_dump_:  Out of room for dump DUMPID
 5303 
 5304 
 5305      Stream:   as (severity2)
 5306 
 5307      Time:     While system is running.
 5308 
 5309      Meaning:  An  error  occurred  while  dumping.   No dump was
 5310                taken.
 5311 
 5312      Action:   Contact the system programming staff.
 5313 
 5314 
 5315                [as_hasp_mpx_.pl1]
 5316                as_hasp_mpx_:   Crash  signalled  for  multiplexer
 5317                TTY.
 5318 
 5319 
 5320      Stream:   as (severity 1)
 5321 
 5322      Time:     While system is running.
 5323 
 5324      Meaning:  The physical  connection for the  HASP multiplexer
 5325                on channel  TTY has been broken  either because of
 5326                an  error or  or because   of a  request from  the
 5327                remote host/workstation.
 5328 
 5329      Action:   Check  the console  for a  message concerning this
 5330                channel  from  hasp_mpx.   If  such  a  message is
 5331                found,  refer  to  its  documentation  for further
 5332                action; otherwise, the remote host/workstation has
 5333                requested  termination of  the connection  and the
 5334                I/O  daemons using  this channel  should be logged
 5335                out.
 5336 
 5337 
 5338 
 5339                [as_hasp_mpx_.pl1]
 5340                as_hasp_mpx_:  Duplicate subchannel  name NAME for
 5341                HASP multiplexer TTY.
 5342 
 5343 
 5344      Stream:   as (severity 1)
 5345 
 5346      Time:     In  response  to  a  load_mpx  operator command or
 5347                during system initialization.
 5348 
 5349 
 5350 as_hasp_mpx_                    93            08/21/20     MR12.7^L
 5351 
 5352 
 5353      Meaning:  The  same  name  has  been  used  for  two or more
 5354                subchannels  of the   HASP multiplexer  on channel
 5355                TTY.
 5356 
 5357      Action:   Correct  the CDT  entry for  this multiplexer  and
 5358                reload it.
 5359 
 5360 
 5361                [as_hasp_mpx_.pl1]
 5362                as_hasp_mpx_:     ERROR_MESSAGE.     Cannot    get
 5363                additional  info  from   terminal  type  NAME  for
 5364                multiplexer TTY.
 5365 
 5366 
 5367      Stream:   as (severity 1)
 5368 
 5369      Time:     In  response  to  a  load_mpx  operator command or
 5370                during system initialization.
 5371 
 5372      Meaning:  The terminal type specified  by NAME was not given
 5373                an additional_info string in  its TTT entry.  This
 5374                string  is required  to specify  the configuration
 5375                parameters  for the   HASP multiplexer  on channel
 5376                TTY.
 5377 
 5378      Action:   Check both the CDT  entry for this multiplexer and
 5379                the TTT  entry for the terminal  type.  Either the
 5380                wrong  terminal type was  specified in the  CDT or
 5381                the  terminal  type's  definition  is  incomplete.
 5382                Correct whichever table is in error and reload the
 5383                multiplexer.
 5384 
 5385 
 5386 
 5387                [as_hasp_mpx_.pl1]
 5388                as_hasp_mpx_:    ERROR_MESSAGE.   Creating   event
 5389                channel for multiplexer TTY.
 5390 
 5391 
 5392      Stream:   as (severity 1)
 5393 
 5394      Time:     In  response  to  a  load_mpx  operator command or
 5395                during system initialization.
 5396 
 5397      Meaning:  A system error arose  during the initialization of
 5398                the HASP multiplexer on channel TTY.
 5399 
 5400      Action:   Contact the system programming staff.
 5401 
 5402 
 5403                [as_hasp_mpx_.pl1]
 5404                as_hasp_mpx_:    Invalid  PARM   specification  in
 5405                terminal type NAME for multiplexer TTY.
 5406 
 5407 
 5408 as_hasp_mpx_                    94            08/21/20     MR12.7^L
 5409 
 5410 
 5411      Stream:   as (severity 1)
 5412 
 5413      Time:     In  response  to  a  load_mpx  operator command or
 5414                during system initialization.
 5415 
 5416      Meaning:  The   value   specified   for   the  configuration
 5417                parameter  PARM in  the additional  info string of
 5418                the   terminal  type   NAME  used   for  the  HASP
 5419                multiplexer  on channel  TTY is  not acceptable to
 5420                the system.
 5421 
 5422      Action:   Correct the value of the  parameter in the TTT and
 5423                reload the multiplexer.
 5424 
 5425 
 5426                [as_hasp_mpx_.pl1]
 5427                as_hasp_mpx_:   Invalid subchannel  name NAME  for
 5428                HASP multiplexer TTY.
 5429 
 5430 
 5431      Stream:   as (severity 1)
 5432 
 5433      Time:     In  response  to  a  load_mpx  operator command or
 5434                during system initialization.
 5435 
 5436      Meaning:  The  name specified for  a subchannel of  the HASP
 5437                multiplexer on channel TTY does not conform to the
 5438                conventions  defined  in  MAM  Communications  for
 5439                naming such channels.
 5440 
 5441      Action:   Correct  the CDT  entry for  this multiplexer  and
 5442                reload it.
 5443 
 5444 
 5445                [as_hasp_mpx_.pl1]
 5446                as_hasp_mpx_:  Line type for hasp operator console
 5447                on  multiplexer   TTY  must  be   "HASP_OPR"  when
 5448                configured for login service.
 5449 
 5450 
 5451 
 5452      Stream:   as (severity 1)
 5453 
 5454      Time:     In  response  to  a  load_mpx  operator command or
 5455                during system initialization.
 5456 
 5457      Meaning:  The line type  must be set for HASP_OPR  on a hasp
 5458                operator console subchannel  when it is configured
 5459                for login service.
 5460 
 5461      Action:   Correct  the CDT  entry for  this multiplexer  and
 5462                reload it.
 5463 
 5464 
 5465 
 5466 as_hasp_mpx_                    95            08/21/20     MR12.7^L
 5467 
 5468 
 5469 
 5470 
 5471                [as_hasp_mpx_.pl1]
 5472                as_hasp_mpx_:  Load signalled for multiplexer TTY.
 5473 
 5474 
 5475      Stream:   as (severity 1)
 5476 
 5477      Time:     While system is running.
 5478 
 5479      Meaning:  The  physical  connection  and  initial connection
 5480                protocl  for the  HASP multiplexer  on channel TTY
 5481                has been completed  successfully.  The multiplexer
 5482                is now ready for use.
 5483 
 5484      Action:   Start the appropriate I/O daemon processes for the
 5485                multiplexer    as   indicated   by    the   system
 5486                administrators  or by  the user  who requested the
 5487                multiplexer be loaded.
 5488 
 5489 
 5490 
 5491                [as_hasp_mpx_.pl1]
 5492                as_hasp_mpx_:  More than  17 subchannels specified
 5493                for HASP multiplexer TTY (COUNT).
 5494 
 5495 
 5496      Stream:   as (severity 1)
 5497 
 5498      Time:     In  response  to  a  load_mpx  operator command or
 5499                during system initialization.
 5500 
 5501      Meaning:  The definition of the  HASP multiplexer on channel
 5502                TTY contains too many subchannels.
 5503 
 5504      Action:   Correct  the CDT  entry for  this multiplexer  and
 5505                reload it.
 5506 
 5507 
 5508                [as_hasp_mpx_.pl1]
 5509                as_hasp_mpx_:  Subchannel NAME  of multiplexer TTY
 5510                does not have TYPE service type.
 5511 
 5512 
 5513      Stream:   as (severity 1)
 5514 
 5515      Time:     In  response  to  a  load_mpx  operator command or
 5516                during system initialization.
 5517 
 5518      Meaning:  The specified  subchannel of the  HASP multiplexer
 5519                on  channel TTY  was not  given the  slave service
 5520                type   or,  in   the  case   of  operator  console
 5521                subchannels, slave or login.
 5522 
 5523 
 5524 as_hasp_mpx_                    96            08/21/20     MR12.7^L
 5525 
 5526 
 5527      Action:   Correct  the CDT  entry for  this multiplexer  and
 5528                reload it.
 5529 
 5530 
 5531                [as_hasp_mpx_.pl1]
 5532                as_hasp_mpx_:   Too  many   printers  and  punches
 5533                configured for HASP multiplexer TTY.
 5534 
 5535 
 5536      Stream:   as (severity 1)
 5537 
 5538      Time:     In  response  to  a  load_mpx  operator command or
 5539                during system initialization.
 5540 
 5541      Meaning:  More  than 8 card  punches and line  printers have
 5542                been specified for the HASP multiplexer on channel
 5543                TTY or a card punch and line printer which use the
 5544                same flow control flag  have been specified.  (See
 5545                MAM Communications for a  description of the rules
 5546                for naming card punches and line printers.)
 5547 
 5548      Action:   Correct  the CDT  entry for  this multiplexer  and
 5549                reload it.
 5550 
 5551 
 5552                [as_hasp_mpx_.pl1]
 5553                as_hasp_mpx_:   Unexpected  wakeup  (DATA1  DATA2)
 5554                from process ID.
 5555 
 5556 
 5557      Stream:   as (severity 1)
 5558 
 5559      Time:     While system is running.
 5560 
 5561      Meaning:  A  message  was  received  from  the process whose
 5562                processid  is  the  12-digit  octal  value ID; the
 5563                contents  of  the  message  are  given  by the two
 5564                12-digit octal values DATA1 and DATA2.  No message
 5565                was expected at this time.  The wakeup is ignored.
 5566 
 5567      Action:   No operator action is required.
 5568 
 5569 
 5570                [as_hasp_mpx_.pl1]
 5571                as_hasp_mpx_:   Wakeup  from  multiplexer  TTY has
 5572                invalid state code VALUE.
 5573 
 5574 
 5575      Stream:   as (severity 1)
 5576 
 5577      Time:     While system is running.
 5578 
 5579 
 5580 
 5581 
 5582 as_hasp_mpx_                    97            08/21/20     MR12.7^L
 5583 
 5584 
 5585      Meaning:  A  message  was  received  indicating  a change of
 5586                state for the multiplexer on channel TTY; however,
 5587                the  new state  of the  multiplexer, given  by the
 5588                decimal  number VALUE,  is not  recognized by this
 5589                module.
 5590 
 5591      Action:   Contact the system programming staff.
 5592 
 5593 
 5594                [as_init_.pl1]
 5595                as_init_:    Answering    Service   initialization
 5596                failed.
 5597 
 5598 
 5599      Stream:   as (severity 2)
 5600 
 5601      Time:     System Intialization.
 5602 
 5603      Meaning:  This indicates a logic error in the supervisor, or
 5604                CPU   or  memory  hardware   problems.   Answering
 5605                Service  initialization  failed.   Normally,  this
 5606                message is preceded by  a more specific indication
 5607                of the reason for failure.
 5608 
 5609      Action:   Contact the system  programming staff.  Attempt to
 5610                correct the problem and try startup again.
 5611 
 5612 
 5613 
 5614                [as_init_.pl1]
 5615                as_init_:  CDT rethreading complete.
 5616 
 5617 
 5618      Stream:   as (severity 1)
 5619 
 5620      Time:     System Intialization.
 5621 
 5622      Meaning:  Rethreading  of  Channel  Definition  Table  (CDT)
 5623                entries  into  a  multiplexer/subchannel hierarchy
 5624                completed  successfully.    System  initialization
 5625                continues.
 5626 
 5627      Action:   Contact the system programming staff._sa
 5628 
 5629 
 5630                [as_init_.pl1]
 5631                as_init_:   CDT   threading  inconsistency  found.
 5632                Rethreading.
 5633 
 5634 
 5635      Stream:   as (severity 1)
 5636 
 5637      Time:     System Intialization.
 5638 
 5639 
 5640 as_init_                        98            08/21/20     MR12.7^L
 5641 
 5642 
 5643      Meaning:  An error was detected  while tracing the threading
 5644                of Channel  Definition Table (CDT) entries  into a
 5645                hierarchy    of    multiplexer    and   subchannel
 5646                entries.This  indicates  a   logic  error  in  the
 5647                supervisor,  or CPU  or memory  hardware problems.
 5648                The entire channel hierarchy will be rethreaded.
 5649 
 5650      Action:   Contact the system programming staff._sa
 5651 
 5652 
 5653                [as_init_.pl1]
 5654                as_init_:    Condition   COND   signalled   during
 5655                startup.  Taking AS dump.  CONDITION_INFO
 5656 
 5657 
 5658 
 5659      S.  as (severity 1)
 5660 
 5661      Time:     System Intialization.
 5662 
 5663      Meaning:  An  unexpected  condition   COND  occurred  during
 5664                system initialization.  An  answering service dump
 5665                is  taken.  The  stack trace  information in  this
 5666                dump further  describes the error.  Some  steps of
 5667                Answering   Service    initialization   were   not
 5668                performed.  This  may cause the system  to operate
 5669                incorrectly.  CONDITION_INFO if optionally present
 5670                if  further  information  about  the  condition is
 5671                available.
 5672 
 5673      Action:   Contact the system programming staff.
 5674 
 5675 
 5676                [as_init_.pl1]
 5677                as_init_:     Condition   was    signalled   while
 5678                processing another condition.  CONDITION
 5679 
 5680 
 5681      Stream:   BOS Typewriter (sounds beeper)
 5682 
 5683      Time:     System Intialization.
 5684 
 5685      Meaning:  This indicates a logic error in the supervisor, or
 5686                CPU or memory hardware problems.  During Answering
 5687                Service  initialization,  a  CONDITION  was raised
 5688                while   as_init_  was   already  processing   some
 5689                condition.  It may be that the error occured while
 5690                making  an   as_dump  for  the   first  condition.
 5691                as_init_ will not attempt  to make an as_dump, but
 5692                will instead abort the initialization.
 5693 
 5694      Action:   Contact the system programming staff.
 5695 
 5696 
 5697 
 5698 as_init_                        99            08/21/20     MR12.7^L
 5699 
 5700 
 5701 
 5702 
 5703                [as_init_.pl1]
 5704                as_init_:  ERROR_MESSAGE.
 5705 
 5706 
 5707      Stream:   as (severity 1)
 5708 
 5709      Time:     System Intialization.
 5710 
 5711      Meaning:  A  fatal error  occurred during  Answering Service
 5712                initialization.   Previous  messages  describe the
 5713                error in more detail.
 5714 
 5715      Action:   Contact the system programming staff._sa
 5716 
 5717 
 5718                [as_init_.pl1]
 5719                as_init_:          ERROR_MESSAGE.          Calling
 5720                multiplexer_mgr_$ENTRYPOINT.
 5721 
 5722 
 5723      Stream:   as (severity 1)
 5724 
 5725      Time:     System Intialization.
 5726 
 5727      Meaning:  The  multiplexer_mgr_  failed  when  accessing the
 5728                Channel   Definition   Table    (CDT)   in   >sc1,
 5729                initializing   the  CDT   or  loading   the  FNPs.
 5730                ERROR_MESSAGE  is  the  text  associated  with the
 5731                error    code   returned    by   multiplexer_mgr_.
 5732                Answering   service  initialization   fails.   The
 5733                system  administrator must   enter admin  mode and
 5734                correct the problem.  Then reboot the system.
 5735 
 5736      Action:   Contact the system programming staff._sa
 5737 
 5738 
 5739                [as_init_.pl1]
 5740                as_init_:  ERROR_MESSAGE.  Calling ROUTINE.
 5741 
 5742 
 5743      Stream:   as (severity 1)
 5744 
 5745      Time:     System Intialization.
 5746 
 5747      Meaning:  An  error  occurred  when  calling  ROUTINE during
 5748                Answering  Service initialization.   ERROR_MESSAGE
 5749                is  the  text  associated   with  the  error  code
 5750                returned    by    ROUTINE.     Answering   service
 5751                initialization  fails.   The  system administrator
 5752                must  enter admin  mode and  correct the  problem.
 5753                Then reboot the system.
 5754 
 5755 
 5756 as_init_                       100            08/21/20     MR12.7^L
 5757 
 5758 
 5759      Action:   Contact the system programming staff._sa
 5760 
 5761 
 5762                [as_init_.pl1]
 5763                as_init_:  ERROR_MESSAGE.  Cannot create pit_temp_
 5764 
 5765 
 5766      Stream:   as (severity 1)
 5767 
 5768      Time:     System Intialization.
 5769 
 5770      Meaning:  The system could not create a temporary segment in
 5771                the Answering Service process's process directory.
 5772                This  is a fatal  error that will  cause answering
 5773                service startup to fail.
 5774 
 5775      Action:   Contact the system programming staff._sa
 5776 
 5777 
 5778                [as_init_.pl1]
 5779                as_init_:   ERROR_MESSAGE.  Cannot  create sat.ht.
 5780                REASON
 5781 
 5782 
 5783      Stream:   as (severity 1)
 5784 
 5785      Time:     System Intialization.
 5786 
 5787      Meaning:  This message indicates that  the sat is damaged or
 5788                that a storage system error prevented the creation
 5789                of  a  new  hash  table  for  the  sat.  Answering
 5790                Service startup will fail.
 5791 
 5792      Action:   Contact the system programming staff._sa
 5793 
 5794 
 5795                [as_init_.pl1]
 5796                as_init_:      ERROR_MESSAGE.     cdt_mgr_$thread:
 5797                ADDED_INFO
 5798 
 5799 
 5800      Stream:   as (severity 1)
 5801 
 5802      Time:     System Intialization.
 5803 
 5804      Meaning:  as_init_  called cdt_mgr_$thread  to rethread  the
 5805                Channel  Definition  Table  (CDT)  entries  into a
 5806                multiplexer/subchannel     hierarchy.     cdt_mgr_
 5807                encountered an unexpected error.  ERROR_MESSAGE is
 5808                the text  associated with the error  code returned
 5809                by  cdt_mgr_.   ADDED_INFO  further  describes the
 5810                error  and whether  or not  further rethreading is
 5811                attempted.
 5812 
 5813 
 5814 as_init_                       101            08/21/20     MR12.7^L
 5815 
 5816 
 5817      Action:   Contact the system programming staff._sa
 5818 
 5819 
 5820                [as_init_.pl1]
 5821                as_init_:    ERROR_MESSAGE.    Could   not  create
 5822                SYSTEM_CONTROL_DIR>TABLE.
 5823 
 5824 
 5825      Stream:   as (severity 1)
 5826 
 5827      Time:     System Intialization.
 5828 
 5829      Meaning:  The  Initializer could  not create  a new  segment
 5830                TABLE  in  SYSTEM_CONTROL_DIR.   Answering service
 5831                initialization  fails.   The  system administrator
 5832                must  enter admin  mode, and  type "create TABLE",
 5833                where TABLE is the  name given above.  Then reboot
 5834                the system.
 5835 
 5836      Action:   Contact the system programming staff._sa
 5837 
 5838 
 5839                [as_init_.pl1]
 5840                as_init_:  ERROR_MESSAGE.  Could  not force access
 5841                on SYSTEM_CONTROL_DIR>TABLE.
 5842 
 5843 
 5844      Stream:   as (severity 1)
 5845 
 5846      Time:     System Intialization.
 5847 
 5848      Meaning:  The  Initializer could not  change the ACL  on the
 5849                TABLE  segment  in  SYSTEM_CONTROL_DIR.  Answering
 5850                service   initialization    fails.    The   system
 5851                administrator must  enter admin mode,  and correct
 5852                the problem.  Then reboot the system.
 5853 
 5854      Action:   Contact the system programming staff._sa
 5855 
 5856 
 5857 
 5858 
 5859 
 5860                [as_init_.pl1]
 5861                as_init_:   ERROR_MESSAGE.    Could  not  initiate
 5862                SYSTEM_CONTROL_DIR>TABLE.
 5863 
 5864 
 5865      Stream:   as (severity 1)
 5866 
 5867      Time:     System Intialization.
 5868 
 5869 
 5870 
 5871 
 5872 as_init_                       102            08/21/20     MR12.7^L
 5873 
 5874 
 5875      Meaning:  The  Initializer  could  not  initiate  the  TABLE
 5876                segment in  SYSTEM_CONTROL_DIR.  Answering service
 5877                initialization  fails.   The  system administrator
 5878                must  enter admin  mode, and  correct the problem.
 5879                Then reboot the system.
 5880 
 5881      Action:   Contact the system programming staff._sa
 5882 
 5883 
 5884                [as_init_.pl1]
 5885                as_init_:  ERROR_MESSAGE.  Could  not set priority
 5886                for IPC wait channels.
 5887 
 5888 
 5889      Stream:   as (severity 1)
 5890 
 5891      Time:     System Intialization.
 5892 
 5893      Meaning:  A   call    to   ipc_$set_wait_prior   failed.This
 5894                indicates a logic error  in the supervisor, or CPU
 5895                or memory hardware problems.
 5896 
 5897      Action:   Contact the system programming staff._sa
 5898 
 5899 
 5900                [as_init_.pl1]
 5901                as_init_:  ERROR_MESSAGE.  Could not set RW access
 5902                on SYSTEM_CONTROL_DIR>TABLE.
 5903 
 5904 
 5905      Stream:   as (severity 1)
 5906 
 5907      Time:     System Intialization.
 5908 
 5909      Meaning:  An error occurred attempting to add ACL entries to
 5910                TABLE  in  SYSTEM_CONTROL_DIR.   Answering Service
 5911                initialization  fails.   The  system administrator
 5912                must  enter admin  mode and  correct the  problem.
 5913                Then reboot the system.
 5914 
 5915      Action:   Contact the system programming staff._sa
 5916 
 5917 
 5918                [as_init_.pl1]
 5919                as_init_:   ERROR_MESSAGE.   Error  while defining
 5920                initial work classes.
 5921 
 5922 
 5923      Stream:   as (severity 1)
 5924 
 5925      Time:     System Intialization.
 5926 
 5927 
 5928 
 5929 
 5930 as_init_                       103            08/21/20     MR12.7^L
 5931 
 5932 
 5933      Meaning:  This indicates a logic error in the supervisor, or
 5934                CPU   or  memory  hardware   problems.   Answering
 5935                Service   initialization    fails.    The   system
 5936                administrator  must enter  admin mode  and correct
 5937                the problem.  Then reboot the system.
 5938 
 5939      Action:   Contact the system programming staff._sa
 5940 
 5941 
 5942                [as_init_.pl1]
 5943                as_init_:    ERROR_MESSAGE.    Initialization   of
 5944                MODULE failed.  {ADDED_INFO.}
 5945 
 5946 
 5947      Stream:   as (severity 1)
 5948 
 5949      Time:     System Intialization.
 5950 
 5951      Meaning:  MODULE  was being  initialized when  it detected a
 5952                problem.  It  called sub_err_ to report  the error
 5953                to   as_init_.   ERROR_MESSAGE   gives  the   text
 5954                associated with the error  code MODULE returned to
 5955                as_init_.   If present,  ADDED_INFO gives  further
 5956                details   about  the   problem.   Some   steps  of
 5957                Answering   Service    initialization   were   not
 5958                performed.  This  may cause the system  to operate
 5959                incorrectly.
 5960 
 5961      Action:   Contact the system programming staff.
 5962 
 5963 
 5964                [as_init_.pl1]
 5965                as_init_:    ERROR_MESSAGE.     MODULE   signalled
 5966                sub_error_;        initialization       continues.
 5967                {ADDED_INFO.}
 5968 
 5969 
 5970 
 5971      Stream:   as (severity 1)
 5972 
 5973      Time:     System Intialization.
 5974 
 5975      Meaning:  MODULE  was being  initialized when  it detected a
 5976                problem.  It  called sub_err_ to report  the error
 5977                to   as_init_.   ERROR_MESSAGE   gives  the   text
 5978                associated with the error  code MODULE returned to
 5979                as_init_.   If present,  ADDED_INFO gives  further
 5980                details about the  problem.  Initialization of the
 5981                module continues.
 5982 
 5983      Action:   Contact the system programming staff..
 5984 
 5985 
 5986 
 5987 
 5988 as_init_                       104            08/21/20     MR12.7^L
 5989 
 5990 
 5991                [as_init_.pl1]
 5992                as_init_:  ERROR_MESSAGE.   Repeated CDT threading
 5993                inconsistencies.
 5994 
 5995 
 5996      Stream:   as (severity 1)
 5997 
 5998      Time:     System Intialization.
 5999 
 6000      Meaning:  Channel Definition Table  (CDT) entry threads were
 6001                found  to   be  damaged  even   after  rethreading
 6002                completed  successfully.This   indicates  a  logic
 6003                error in the supervisor, or CPU or memory hardware
 6004                problems.
 6005 
 6006      Action:   Contact the system programming staff._sa
 6007 
 6008 
 6009                [as_init_.pl1]
 6010                as_init_:  ERROR_MESSAGE.  Shutting down the login
 6011                server request mechanism.
 6012 
 6013 
 6014      Stream:   as (severity 1)
 6015 
 6016      Time:     System shutdown.
 6017 
 6018      Meaning:  An  error occurred  while shutting  down the login
 6019                server request mechanism.  The ERROR_MESSAGE gives
 6020                the text  associated with the error  code returned
 6021                from ls_request_server_$shutdown.
 6022 
 6023      Action:   No operator action is required.
 6024 
 6025 
 6026                [as_init_.pl1]
 6027                as_init_:                           ERROR_MESSAGE.
 6028                SYSTEM_CONTROL_DIR>TABLE.  Forcing access.
 6029 
 6030 
 6031      Stream:   as (severity 1)
 6032 
 6033      Time:     System Intialization.
 6034 
 6035      Meaning:  During    system    initialization,    TABLE    in
 6036                SYSTEM_CONTROL_DIR was found  to have an incorrect
 6037                ACL.  Access was set for Initializer.SysDaemon.
 6038 
 6039      Action:   No operator action is required.
 6040 
 6041 
 6042 
 6043 
 6044 
 6045 
 6046 as_init_                       105            08/21/20     MR12.7^L
 6047 
 6048 
 6049                [as_init_.pl1]
 6050                as_init_:   installation_parms  damaged.   N  rate
 6051                structures defined; from I to J allowed.
 6052 
 6053 
 6054 
 6055      Stream:   as (severity 1)
 6056 
 6057      Time:     System Intialization.
 6058 
 6059      Meaning:  The installation_parms table  claims to declare an
 6060                unallowed   number  of   rate  structures.    This
 6061                indicates  that the  table has  been damaged.  The
 6062                system  administrator  must  rectify  the  problem
 6063                using   ed_installation_parms  from   admin  mode,
 6064                before the Answering  Service will initialize.  It
 6065                will  be  necessary  to  re-boot  Multics to retry
 6066                Answering Service initialization.
 6067 
 6068      Action:   Contact the system programming staff._sa
 6069 
 6070 
 6071                [as_init_.pl1]
 6072                as_init_:    Multics   SYSID;   Answering  Service
 6073                VERSION
 6074 
 6075 
 6076      Stream:   as (severity 1)
 6077 
 6078      Time:     System Intialization.
 6079 
 6080      Meaning:  Answering  Service initialization is  complete and
 6081                users may now log  in.  The current system version
 6082                number,  from  the  system  tape,  is  SYSID.  The
 6083                current   Answering  Service  version   number  is
 6084                VERSION.
 6085 
 6086      Action:   Proceed with startup.
 6087 
 6088 
 6089                [as_init_.pl1]
 6090                as_init_:   No  "tcd"  card  in  the  config deck.
 6091                Assuming APT size of 1000.
 6092 
 6093 
 6094      Stream:   as (severity 1)
 6095 
 6096      Time:     System Intialization.
 6097 
 6098      Meaning:  This message  indicates that there is  no TCD card
 6099                in  the  config  deck.   The  system  will operate
 6100                normally, but  it is recommended that  an explicit
 6101                TCD card be added at the first convenience.
 6102 
 6103 
 6104 as_init_                       106            08/21/20     MR12.7^L
 6105 
 6106 
 6107      Action:   Contact the system programming staff._sa
 6108 
 6109 
 6110                [as_init_.pl1]
 6111                as_init_:  rebuilding SAT hash table.
 6112 
 6113 
 6114      Stream:   as (severity 1)
 6115 
 6116      Time:     System Intialization.
 6117 
 6118      Meaning:  The  hash table  for the  SAT was  corrupted.  The
 6119                hash table is regenerated.
 6120 
 6121      Action:   No operator action is required.
 6122 
 6123 
 6124                [as_init_.pl1]
 6125                as_init_:    Resource   management   is  disabled;
 6126                >sc1>rtdt needs it enabled.
 6127 
 6128 
 6129      Stream:   as (severity 1)
 6130 
 6131      Time:     System Intialization.
 6132 
 6133      Meaning:  The  copy  of  installation_parms  encountered  by
 6134                system startup claims that RCP resource management
 6135                is disabled.   This disagrees with  information in
 6136                the  RTDT.   If  startup  were  to  continue,  all
 6137                information in resource  registries would be lost.
 6138                Answering   Service  initialization   fails.   The
 6139                system        administrator        must        use
 6140                ed_installation_parms  from admin  mode to  repair
 6141                the damage.  Then reboot the system.
 6142 
 6143      Action:   Contact the system programming staff._sa
 6144 
 6145 
 6146                [as_init_.pl1]
 6147                as_init_:     SAT   version    inconsistent   with
 6148                declarations used in this program.
 6149 
 6150 
 6151      Stream:   as (severity 1)
 6152 
 6153      Time:     System Intialization.
 6154 
 6155      Meaning:  The  version number  stored  in  the SAT  does not
 6156                match  the  expected  version  number,  which is a
 6157                constant in the  Answering Service programs.  This
 6158                may  be because  the  SAT  has been  destroyed, or
 6159                because  an  incorrect  version  of  the Answering
 6160 
 6161 
 6162 as_init_                       107            08/21/20     MR12.7^L
 6163 
 6164 
 6165                Service  programs is  being used.   BOS Typewriter
 6166                (Crashes system)es
 6167 
 6168      Action:   Contact  the  system   programming  staff._sa  The
 6169                System  Administrator must  either generate  a new
 6170                SAT,  or  install  the   correct  version  of  the
 6171                Answering Service.  If the System Administrator is
 6172                not  available, enter  admin mode  and attempt  to
 6173                retrieve a recent copy of the SAT.  Then exit from
 6174                admin mode and try startup again.
 6175 
 6176 
 6177 
 6178                [as_init_.pl1]
 6179                as_init_:     SYSTEM_CONTROL_DIR>TABLE    missing.
 6180                Creating new one.
 6181 
 6182 
 6183      Stream:   as (severity 1)
 6184 
 6185      Time:     System Intialization.
 6186 
 6187      Meaning:  A   new   version   of   TABLE   was   created  in
 6188                SYSTEM_CONTROL_DIR     as    part     of    system
 6189                initialization.
 6190 
 6191      Action:   No operator action is required.
 6192 
 6193 
 6194                [as_init_.pl1]
 6195                as_init_:  The requested action was not performed.
 6196                Cannot type go twice.
 6197 
 6198 
 6199      Stream:   as (severity 1)
 6200 
 6201      Time:     System Intialization.
 6202 
 6203      Meaning:  The operator typed go  when Multics was already in
 6204                operation.  No action was taken.
 6205 
 6206      Action:   No operator action is required.
 6207 
 6208 
 6209                [as_init_.pl1]
 6210                as_init_:  The requested action was not performed.
 6211                Type multics first.
 6212 
 6213 
 6214      Stream:   as (severity 1)
 6215 
 6216      Time:     System Intialization.
 6217 
 6218 
 6219 
 6220 as_init_                       108            08/21/20     MR12.7^L
 6221 
 6222 
 6223      Meaning:  The operator typed go  without typing multics.  No
 6224                action was taken.
 6225 
 6226      Action:   Type multics first, or startup.
 6227 
 6228 
 6229                [as_init_.pl1]
 6230                as_init_:  The requested action was not performed.
 6231                Multics already initialized.
 6232 
 6233 
 6234      Stream:   as (severity 1)
 6235 
 6236      Time:     System Intialization.
 6237 
 6238      Meaning:  The  operator typed  startup, multics,  or go when
 6239                Multics was  already in operation.  No  action was
 6240                taken.
 6241 
 6242      Action:   No operator action is required.
 6243 
 6244 
 6245                [as_init_.pl1]
 6246                as_init_:  This  procedure does not  implement the
 6247                requested version.  installation_parms version N.
 6248 
 6249 
 6250 
 6251      Stream:   as (severity 1)
 6252 
 6253      Time:     System Intialization.
 6254 
 6255      Meaning:  This indicates a logic error in the supervisor, or
 6256                CPU    or   memory    hardware   problems.     The
 6257                installation_parms segment has  been damaged or is
 6258                not  up-to-date.   The  system  administrator must
 6259                rectify  the  problem  using ed_installation_parms
 6260                from admin mode, before the Answering Service will
 6261                initialize.   It  will  be  necessary  to  re-boot
 6262                Multics to retry Answering Serviceinitialization.
 6263 
 6264      Action:   Contact the system programming staff._sa
 6265 
 6266 
 6267                [as_lap_mpx_.pl1]
 6268                as_lap_mpx:   Unexpected  signal  for  multiplexer
 6269                MPX.
 6270 
 6271 
 6272      Stream:   as (severity1)
 6273 
 6274      Time:     While system is running.
 6275 
 6276 
 6277 
 6278 as_lap_mpx                     109            08/21/20     MR12.7^L
 6279 
 6280 
 6281      Meaning:  An unknown type event was signaled for multiplexer
 6282                MPX.  It will be ignored.
 6283 
 6284      Action:   Contact the system programming staff.
 6285 
 6286 
 6287                [as_lap_mpx_.pl1]
 6288                as_lap_mpx_:  Bad argument to parm PPPP, should be
 6289                XXXX or YYYY
 6290 
 6291 
 6292      Stream:   as (severity1)
 6293 
 6294      Time:     In  response to  an operator  load_mpx command for
 6295                during system startup.
 6296 
 6297      Meaning:  A bad  value was specified for  the PPPP parameter
 6298                in the  TTF entry for this  muliplexer.  Its value
 6299                must be either XXXX or YYYY.
 6300 
 6301      Action:   Check  the  contents  of  the  TTF  entry  for the
 6302                terminal_type associated with  the multiplexer for
 6303                errors.
 6304 
 6305 
 6306 
 6307                [as_lap_mpx_.pl1]
 6308                as_lap_mpx_:  Crash signalled for multiplexer MPX.
 6309 
 6310 
 6311      Stream:   as (severity1)
 6312 
 6313      Time:     While system is running.
 6314 
 6315      Meaning:  The  multiplexer has  crashed.  The  LAP link  has
 6316                entered the disconnected state.
 6317 
 6318      Action:   Contact the system programming staff.
 6319 
 6320 
 6321                [as_lap_mpx_.pl1]
 6322                as_lap_mpx_:   Error  in  conversion.   Converting
 6323                FIELD VALUE to a number for multiplexer MPX.
 6324 
 6325 
 6326      Stream:   as (severity1)
 6327 
 6328      Time:     In  response to  an operator  load_mpx command  or
 6329                during system start up.
 6330 
 6331      Meaning:  It was  impossible to convert a  numeric parameter
 6332                from  the terminal_type additional_info  string to
 6333                its  internal  form.   FIELD  is  the  name of the
 6334 
 6335 
 6336 as_lap_mpx_                    110            08/21/20     MR12.7^L
 6337 
 6338 
 6339                parameter  in error.   VALUE is  the string  which
 6340                could not be converted.
 6341 
 6342      Action:   Check  the  contents  of  the  TTF  entry  for the
 6343                terminal_type associated with  the multiplexer for
 6344                errors.
 6345 
 6346 
 6347 
 6348                [as_lap_mpx_.pl1]
 6349                as_lap_mpx_:   ERROR.  Cannot get  additional info
 6350                for terminal type TTP for multiplexer MPX.
 6351 
 6352 
 6353      Stream:   as (severity1)
 6354 
 6355      Time:     In  response to  an operator  load_mpx command  or
 6356                during system start up.
 6357 
 6358      Meaning:  An error occurred  while retrieving the parameters
 6359                of  the  multiplexer  from  the  TTT.   Either the
 6360                terminal type specified in  the CDT does not exist
 6361                or    it   does    not   contain    the   required
 6362                additional_info field.
 6363 
 6364      Action:   Check  that the  CMF  and  TTF contain  the proper
 6365                information.
 6366 
 6367 
 6368                [as_lap_mpx_.pl1]
 6369                as_lap_mpx_:   ERROR.  Creating event  channel for
 6370                multiplexer MPX.
 6371 
 6372 
 6373      Stream:   as (severity1)
 6374 
 6375      Time:     In  response to  an operator  load_mpx command  or
 6376                during system start up.
 6377 
 6378      Meaning:  An ipc_ error occurred  while trying to initialize
 6379                the multiplexer.
 6380 
 6381      Action:   Contact the system programming staff.
 6382 
 6383 
 6384                [as_lap_mpx_.pl1]
 6385                as_lap_mpx_:  Load failed for multiplexer MPX.
 6386 
 6387 
 6388      Stream:   as (severity1)
 6389 
 6390      Time:     In  response to  an operator  load_mpx command  or
 6391                during system start up.
 6392 
 6393 
 6394 as_lap_mpx_                    111            08/21/20     MR12.7^L
 6395 
 6396 
 6397      Meaning:  The attempt to load  the multiplexer failed.  This
 6398                should never happen.
 6399 
 6400      Action:   Contact the system programming staff.
 6401 
 6402 
 6403                [as_lap_mpx_.pl1]
 6404                as_lap_mpx_:  Load signalled for multiplexer MPX.
 6405 
 6406 
 6407      Stream:   as (severity1)
 6408 
 6409      Time:     In  response to  an operator  load_mpx command  or
 6410                during system start up.
 6411 
 6412      Meaning:  The multiplexer has  been successfully loaded.  It
 6413                will  be  started  unless  the  -no_start  control
 6414                argument was  given when the load_mpx  command was
 6415                typed.
 6416 
 6417      Action:   No operator action is required.
 6418 
 6419 
 6420                [as_lap_mpx_.pl1]
 6421                as_lap_mpx_:    Unexpected   wakeup   (DATA)  from
 6422                process PRCID.
 6423 
 6424 
 6425      Stream:   as (severity1)
 6426 
 6427      Time:     While system is running.
 6428 
 6429      Meaning:  The multiplexer manager received  a wakeup from an
 6430                unexpected source.  The wakeup is ignored.
 6431 
 6432      Action:   No operator action is required.
 6433 
 6434 
 6435                [as_lap_mpx_.pl1]
 6436                as_lap_mpx_:   Wakeup  for   multiplexer  MPX  has
 6437                invalid state code STATE.
 6438 
 6439 
 6440      Stream:   as (severity1)
 6441 
 6442      Time:     While system is running.
 6443 
 6444      Meaning:  A  wakeup with  invalid data  was received  by the
 6445                multiplexer manager.  The wakeup is ignored.
 6446 
 6447      Action:   Contact the system programming staff.
 6448 
 6449 
 6450 
 6451 
 6452 as_mcs_mpx_ (trace)            112            08/21/20     MR12.7^L
 6453 
 6454 
 6455                [as_mcs_mpx_.pl1]
 6456                as_mcs_mpx_  (trace):  FNP FNP_NUMBER,  MPXE state
 6457                MPX_STATE, FNP state FNP_STATE{, deconfigured}.
 6458 
 6459 
 6460 
 6461      Stream:   as (severity 1)
 6462 
 6463      Time:     While system is running.
 6464 
 6465      Meaning:  This  is  a  tracing  message  which displays some
 6466                values  of variables  that describe  the status of
 6467                the FNP.
 6468 
 6469      Action:   Contact the system programming staff.
 6470 
 6471 
 6472                [as_mcs_mpx_.pl1]
 6473                as_mcs_mpx_:  Crash signalled for FNP TAG.
 6474 
 6475 
 6476      Stream:   as (severity 1)
 6477 
 6478      Time:     While system is running.
 6479 
 6480      Meaning:  FNP TAG has crashed.  A  reload of the FNP will be
 6481                attempted  if it  is not  in a  crash loop  or not
 6482                inactive.
 6483 
 6484      Action:   Contact the system programming staff.
 6485 
 6486 
 6487                [as_mcs_mpx_.pl1]
 6488                as_mcs_mpx_:                    ERROR_CODE_MESSAGE
 6489                >sc1>fnp_crash_notify.ec does not exist.
 6490 
 6491 
 6492      Stream:   as (severity 1)
 6493 
 6494      Time:     While system is running.
 6495 
 6496      Meaning:  An   error   occured   (ERROR_CODE_MESSAGE)   when
 6497                checking for the  existence of fnp_crash_notify.ec
 6498                in the system_control_1 directory.
 6499 
 6500      Action:   Contact the system programming staff.
 6501 
 6502 
 6503                [as_mcs_mpx_.pl1]
 6504                as_mcs_mpx_:   ERROR_CODE_MESSAGE  Creating  event
 6505                channel for FNP TAG.
 6506 
 6507 
 6508 
 6509 
 6510 as_mcs_mpx_                    113            08/21/20     MR12.7^L
 6511 
 6512 
 6513      Stream:   as (severity 1)
 6514 
 6515      Time:     While system is running.
 6516 
 6517      Meaning:  An  error  occured  (ERROR_CODE_MESSAGE)  when  an
 6518                attempt  was made to  create an event  channel for
 6519                FNP TAG.  The load attempt has been aborted.  This
 6520                message  can also  be logged  if an  error occured
 6521                when changing the  just created event-wait channel
 6522                into an event-call channel.
 6523 
 6524      Action:   Contact the system programming staff.
 6525 
 6526 
 6527                [as_mcs_mpx_.pl1]
 6528                as_mcs_mpx_:     ERROR_CODE_MESSAGE   Failed    to
 6529                establish an SCI environment.
 6530 
 6531 
 6532      Stream:   as (severity 1)
 6533 
 6534      Time:     While system is running.
 6535 
 6536      Meaning:  An error occured  (ERROR_CODE_MESSAGE) when trying
 6537                to create an  system control subsystem environment
 6538                pointer.
 6539 
 6540      Action:   Contact the system programming staff.
 6541 
 6542 
 6543                [as_mcs_mpx_.pl1]
 6544                as_mcs_mpx_:   ERROR_CODE_MESSAGE   Reading  event
 6545                channel for FNP TAG.
 6546 
 6547 
 6548      Stream:   as (severity 1)
 6549 
 6550      Time:     While system is running.
 6551 
 6552      Meaning:  An  error  occured  (ERROR_CODE_MESSAGE)  when  an
 6553                attempt  was  made  to  read  the  bootload  event
 6554                channel for FNP TAG.
 6555 
 6556      Action:   Contact the system programming staff.
 6557 
 6558 
 6559                [as_mcs_mpx_.pl1]
 6560                as_mcs_mpx_:   ERROR_CODE_MESSAGE Resetting  event
 6561                channel for FNP TAG.
 6562 
 6563 
 6564      Stream:   as (severity 1)
 6565 
 6566 
 6567 
 6568 as_mcs_mpx_                    114            08/21/20     MR12.7^L
 6569 
 6570 
 6571      Time:     While system is running.
 6572 
 6573      Meaning:  An  error  occured  (ERROR_CODE_MESSAGE)  when  an
 6574                attempt was made to drain  all events from the FNP
 6575                boot event channel.
 6576 
 6577      Action:   Contact the system programming staff.
 6578 
 6579 
 6580                [as_mcs_mpx_.pl1]
 6581                as_mcs_mpx_:   ERROR_CODE_MESSAGE  Taking  dump of
 6582                FNP TAG.  FNP_DUMP_ENTRY_NAME
 6583 
 6584 
 6585      Stream:   as (severity 1)
 6586 
 6587      Time:     While system is running.
 6588 
 6589      Meaning:  An  error  occured  (ERROR_CODE_MESSAGE)  when  an
 6590                attempt  was  made  to   dump  FNP  TAG  into  the
 6591                FNP_DUMP_ENTRY_NAME segment in >dumps.
 6592 
 6593      Action:   Contact the system programming staff.
 6594 
 6595 
 6596                [as_mcs_mpx_.pl1]
 6597                as_mcs_mpx_:    FDUMP  of   FNP  TAG   created  in
 6598                >dumps>FNP_DUMP_ENTRY_NAME
 6599 
 6600 
 6601      Stream:   as (severity 1)
 6602 
 6603      Time:     While system is running.
 6604 
 6605      Meaning:  FNP  TAG  has  been  dumped  successfully into the
 6606                >dumps>FNP_DUMP_ENTRY_NAME   segment    after   it
 6607                crashed.
 6608 
 6609      Action:   Contact the system programming staff.
 6610 
 6611 
 6612                [as_mcs_mpx_.pl1]
 6613                as_mcs_mpx_:   Inconsistent  wakeup  received from
 6614                FNP  TAG.   FNP  state  =  FNP_STATE,  msg state =
 6615                MSG_STATE.
 6616 
 6617 
 6618 
 6619      Stream:   as (severity 1)
 6620 
 6621      Time:     While system is running.
 6622 
 6623 
 6624 
 6625 
 6626 as_mcs_mpx_                    115            08/21/20     MR12.7^L
 6627 
 6628 
 6629      Meaning:  The  data in the  message from the  bootload event
 6630                channel for FNP TAG indicates  that the FNP was in
 6631                an inconsistant state (MSG_STATE) with the current
 6632                state (FNP_STATE) of the FNP in the CDT.
 6633 
 6634      Action:   Contact the system programming staff.
 6635 
 6636 
 6637                [as_mcs_mpx_.pl1]
 6638                as_mcs_mpx_:  Invalid wakeup received for FNP TAG.
 6639                Wakeup   appears   to   be   for   FNP   OTHER_TAG
 6640                (#FNP_NUMBER).
 6641 
 6642 
 6643 
 6644      Stream:   as (severity 1)
 6645 
 6646      Time:     While system is running.
 6647 
 6648      Meaning:  Invalid wakeup received  on bootload event channel
 6649                for FNP TAG.  Wakeup data  indicates it is for FNP
 6650                OTHER_TAG whose number is FNP_NUMBER.
 6651 
 6652      Action:   Contact the system programming staff.
 6653 
 6654 
 6655                [as_mcs_mpx_.pl1]
 6656                as_mcs_mpx_:  Load failed for FNP TAG.
 6657 
 6658 
 6659      Stream:   as (severity 1)
 6660 
 6661      Time:     While system is running.
 6662 
 6663      Meaning:  The FNP TAG failed to load successfully.
 6664 
 6665      Action:   Try  the  bootload   attempt  again.   If  problem
 6666                persists, contact the programing staff.
 6667 
 6668 
 6669 
 6670                [as_mcs_mpx_.pl1]
 6671                as_mcs_mpx_:   Load of  FNP TAG  did not  complete
 6672                within X minutes.
 6673 
 6674 
 6675      Stream:   as (severity 2)
 6676 
 6677      Time:     While system is running.
 6678 
 6679      Meaning:  FNP TAG  did not signal that it  had completed the
 6680                load  attempt within  the required  X minutes from
 6681                the time that the image was sent to the FNP.
 6682 
 6683 
 6684 as_mcs_mpx_                    116            08/21/20     MR12.7^L
 6685 
 6686 
 6687      Action:   Try to  load the FNP again.   If problem persists,
 6688                contact system programing staff.
 6689 
 6690 
 6691 
 6692                [as_mcs_mpx_.pl1]
 6693                as_mcs_mpx_:  Load signalled for FNP TAG.
 6694 
 6695 
 6696      Stream:   as (severity 1)
 6697 
 6698      Time:     While system is running.
 6699 
 6700      Meaning:  FNP TAG bootloaded successfully.
 6701 
 6702      Action:   No operator action is required.
 6703 
 6704 
 6705                [as_mcs_mpx_.pl1]
 6706                as_mcs_mpx_:  Procedure called with bad fnpep into
 6707                cdt:  POINTER
 6708 
 6709 
 6710      Stream:   as (severity 1)
 6711 
 6712      Time:     While system is running.
 6713 
 6714      Meaning:  The  compute_fnp_no  internal  procedure  detected
 6715                that  as_mcs_mpx_  was  supplied  with  a prointer
 6716                value (POINTER) that should  point to an FNP entry
 6717                in  the CDT  but doesn't.   Current operation  has
 6718                been aborted.
 6719 
 6720      Action:   Contact the system programming staff.
 6721 
 6722 
 6723                [as_mcs_mpx_.pl1]
 6724                as_mcs_mpx_:  Tracing off.
 6725 
 6726 
 6727      Stream:   as (severity 1)
 6728 
 6729      Time:     While system is running.
 6730 
 6731      Meaning:  The trace_off entry point  has been called and now
 6732                tracing has been disabled.
 6733 
 6734      Action:   Contact the system programming staff.
 6735 
 6736 
 6737                [as_mcs_mpx_.pl1]
 6738                as_mcs_mpx_:  Tracing on.
 6739 
 6740 
 6741 
 6742 as_mcs_mpx_                    117            08/21/20     MR12.7^L
 6743 
 6744 
 6745      Stream:   as (severity 1)
 6746 
 6747      Time:     While system is running.
 6748 
 6749      Meaning:  The trace_on  entry point has been  called so that
 6750                as_mcs_mpx_ trace data will now be displayed.
 6751 
 6752      Action:   Contact the system programming staff.
 6753 
 6754 
 6755                [as_mcs_mpx_.pl1]
 6756                as_mcs_mpx_:   Unexpected   wakeup  (EV_MSG_WORD_1
 6757                EV_MSG_WORD_2) from process PROC_ID.
 6758 
 6759 
 6760 
 6761      Stream:   as (severity 1)
 6762 
 6763      Time:     While system is running.
 6764 
 6765      Meaning:  An  unexpected wakeup  occured on  an FNP bootload
 6766                event  channel from   process PROC_ID.   The event
 6767                message    data    is    in    EV_MSG_WORD_1   and
 6768                EV_MSG_WORD_2.  Unable to determine FNP tag.
 6769 
 6770      Action:   Contact the system programming staff.
 6771 
 6772 
 6773                [as_mcs_mpx_.pl1]
 6774                as_mcs_mpx_:  Wakeup for FNP TAG has invalid state
 6775                code:  CODE.
 6776 
 6777 
 6778      Stream:   as (severity 1)
 6779 
 6780      Time:     While system is running.
 6781 
 6782      Meaning:  Wakeup  message data   received on  bootload event
 6783                channel for FNP TAG contains an invalid state code
 6784                value  of CODE.   Valid values  for mpxe.state are
 6785                defined  in the  cdt.incl.pl1 include  file by the
 6786                FNP_* variables.
 6787 
 6788      Action:   Contact the system programming staff.
 6789 
 6790 
 6791                [as_mcs_mpx_.pl1]
 6792                as_mcs_mpx_:    Wakeup  with   bad  data   pointer
 6793                ignored:  POINTER
 6794 
 6795 
 6796      Stream:   as (severity 1)
 6797 
 6798 
 6799 
 6800 as_mcs_mpx_                    118            08/21/20     MR12.7^L
 6801 
 6802 
 6803      Time:     While system is running.
 6804 
 6805      Meaning:  A  wakeup was  received on  an FNP  bootload event
 6806                channel  with   which  a  bad  data   pointer  was
 6807                supplied.  Unable to determine FNP tag.
 6808 
 6809      Action:   Contact the system programming staff.
 6810 
 6811 
 6812                [as_meter_.pl1]
 6813                as_meter_:  FDUMP number is NNN
 6814 
 6815 
 6816      Stream:   as (severity1)
 6817 
 6818      Time:     System Intialization.
 6819 
 6820      Meaning:  The system is coming up after a crash.  There is a
 6821                dump, created by the bce dump command, in the DUMP
 6822                partition.   Usually,   system_start_up.ec  copies
 6823                this dump into the directory >dumps.
 6824 
 6825      Action:   Follow site instructions concerning the processing
 6826                of online  dumps.  The normal procedure  is to log
 6827                in   Print_Dump.SysDaemon  and  request   that  it
 6828                process the dump.
 6829 
 6830 
 6831 
 6832                [as_meter_.pl1]
 6833                as_meter_:   Problem   getting  "ITEM".   Metering
 6834                disabled.
 6835 
 6836 
 6837      Stream:   as (severity2)
 6838 
 6839      Time:     System Intialization.
 6840 
 6841      Meaning:  The metering module cannot obtain a pointer to the
 6842                ring   0  hardcore   data  item   ITEM,  used   in
 6843                calculating  system usage.   Metering figures  are
 6844                scrambled, but the system should be able to run.
 6845 
 6846      Action:   Contact the system programming staff.
 6847 
 6848 
 6849                [as_request_bump_user_.pl1]
 6850                as_request_bump_user_:     BUMPING   PERS.PROJ.TAG
 6851                PROCESSID for requestor REQ_PERS.REQ_PROJ.REQ_TAG.
 6852 
 6853 
 6854 
 6855      Stream:   as (severity 0)
 6856 
 6857 
 6858 as_request_bump_user_          119            08/21/20     MR12.7^L
 6859 
 6860 
 6861      Time:     While system is running.
 6862 
 6863      Meaning:  An     answering      service     request     from
 6864                REQ_PERS.REQ_PROJ.REQ_TAG  to   bump  the  process
 6865                PERS.PROJ.TAG PROCESSID has been initiated.
 6866 
 6867      Action:   No operator action is required.
 6868 
 6869 
 6870                [as_request_bump_user_.pl1]
 6871                as_request_bump_user_:     ERROR_MSG.     Rejected
 6872                BUMP_USER  request  from   PERS.PROJ.TAG  to  bump
 6873                process PROCESS_ID.  REASON
 6874 
 6875 
 6876 
 6877      Stream:   as (severity 0)
 6878 
 6879      Time:     While system is running.
 6880 
 6881      Meaning:  The  answering service request  from PERS.PROJ.TAG
 6882                to bump the process identified by PROCESSID failed
 6883                for the given REASON and ERROR_MSG.
 6884 
 6885      Action:   Contact the system programming staff._sa
 6886 
 6887 
 6888                [as_request_note_pnt_change_.pl1]
 6889                as_request_note_pnt_change_:      Bumping     user
 6890                PERS.PROJ.TAG PROCESSID on channel CHN.  (REASON)
 6891 
 6892 
 6893 
 6894      Stream:   as (severity 0)
 6895 
 6896      Time:     While system is running.
 6897 
 6898      Meaning:  Process PERS.PROJ.TAG on channel CHN was bumped by
 6899                a  change  to  the  PNT  entry  for  PERS.  REASON
 6900                describes the type of PNT change.
 6901 
 6902      Action:   No operator action is required.
 6903 
 6904 
 6905 
 6906                [as_request_note_pnt_change_.pl1]
 6907                as_request_note_pnt_change_:  ERROR_MSG.  Rejected
 6908                NOTE_PNT_CHANGE request from PERS.PROJ.  REASON
 6909 
 6910 
 6911 
 6912      Stream:   as (severity 0)
 6913 
 6914 
 6915 
 6916 as_request_note_pnt_change_    120            08/21/20     MR12.7^L
 6917 
 6918 
 6919      Time:     While system is running.
 6920 
 6921      Meaning:  An answering  service request to note  a change to
 6922                the  PNT  sent  by  PERS.PROJ  failed  because  of
 6923                REASON.This  indicates   a  logic  error   in  the
 6924                supervisor, or CPU or memory hardware problems.
 6925 
 6926      Action:   Contact the system programming staff.
 6927 
 6928 
 6929 
 6930                [as_request_note_pnt_change_.pl1]
 6931                as_request_note_pnt_change_:     Lowered   maximum
 6932                authorization  for  PERS.PROJ.TAG  on  channel CHN
 6933                from OLD_MAX_AUTH to NEW_MAX_AUTH.  PNT change.
 6934 
 6935 
 6936 
 6937      Stream:   as (severity 0)
 6938 
 6939      Time:     While system is running.
 6940 
 6941      Meaning:  A  change to  the PNT  entry for  PERS lowered the
 6942                maximum authorization associated  with the process
 6943                PERS.PROJ.TAG  on channel CHN.   The authorization
 6944                was changed from OLD_MAX_AUTH to NEW_MAX_AUTH.
 6945 
 6946      Action:   No operator action is required.
 6947 
 6948 
 6949 
 6950                [as_request_note_pnt_change_.pl1]
 6951                as_request_note_pnt_change_:     Raised    minimum
 6952                authorization  for  PERS.PROJ.TAG  on  channel CHN
 6953                from OLD_MIN_AUTH to NEW_MIN_AUTH.  PNT change.
 6954 
 6955 
 6956 
 6957      Stream:   as (severity 0)
 6958 
 6959      Time:     While system is running.
 6960 
 6961      Meaning:  A  change to  the PNT  entry for  PERS raised  the
 6962                minimum authorization associated  with the process
 6963                PERS.PROJ.TAG  on channel CHN.   The authorization
 6964                was changed from OLD_MIN_AUTH to NEW_MIN_AUTH.
 6965 
 6966      Action:   No operator action is required.
 6967 
 6968 
 6969 
 6970                [as_request_note_pnt_change_.pl1]
 6971                as_request_note_pnt_change_:   User  has  "nobump"
 6972 
 6973 
 6974 as_request_note_pnt_change_    121            08/21/20     MR12.7^L
 6975 
 6976 
 6977                attribute.   Did not bump  PERS.PROJ.TAG PROCESSID
 6978                on channel CHN.  (REASON)
 6979 
 6980 
 6981 
 6982      Stream:   as (severity 0)
 6983 
 6984      Time:     While system is running.
 6985 
 6986      Meaning:  Bump   attempt  for  process   PERS.PROJ.TAG  with
 6987                PROCESSID on channel CHN  failed, because the user
 6988                has  the nobump  attribute.  REASON  indicates why
 6989                bumping was attempted.
 6990 
 6991      Action:   Contact the system programming staff._sa
 6992 
 6993 
 6994 
 6995                [as_request_server_.pl1]
 6996                as_request_sender_:    MSG.    Could   not  delete
 6997                message MID for PERS.PROJ.
 6998 
 6999 
 7000      Stream:   as (severity0)
 7001 
 7002      Time:     While system is running.
 7003 
 7004      Meaning:  MSG is  an error_table_ message, MID  is a message
 7005                ID, PERS.PROJ  is the group  ID of the  AS request
 7006                sender.   The  AS  request  message  could  not be
 7007                deleted after executing the AS request.
 7008 
 7009      Action:   No operator action is required.
 7010 
 7011 
 7012                [as_request_server_.pl1]
 7013                as_request_sender_:   PERS.PROJ  (PID)  set  fatal
 7014                process error [logout|new_proc].
 7015 
 7016 
 7017      Stream:   as (severity0)
 7018 
 7019      Time:     While system is running.
 7020 
 7021      Meaning:  The  process group  id PERS.PROJ  (process id PID)
 7022                has  set the  AS flag  which indicates  that fatal
 7023                process errors will cause a {logout|new_proc}.
 7024 
 7025      Action:   No operator action is required.
 7026 
 7027 
 7028                [as_request_server_.pl1]
 7029 
 7030 
 7031 
 7032 as_request_server_$init        122            08/21/20     MR12.7^L
 7033 
 7034 
 7035                as_request_server_$init:       MSG.       Deleting
 7036                >sc1>as_request_.ms.
 7037 
 7038 
 7039      Stream:   as (severity1)
 7040 
 7041      Time:     Answering Service initialization.
 7042 
 7043      Meaning:  MSG  is  an  error_table_  message.   An error was
 7044                encountered   while  attempting   to  delete   the
 7045                as_request  message segment, prior  to re-creating
 7046                it.     as_request_server_$init   continues    and
 7047                attempts to create the message segment.
 7048 
 7049      Action:   No operator action is required.
 7050 
 7051 
 7052                [as_request_server_.pl1]
 7053                as_request_server_$init:     MSG.     Manipulating
 7054                >sc1>as_request_.ms or IPC channels.
 7055 
 7056 
 7057      Stream:   as (severity1)
 7058 
 7059      Time:     Answering Service initialization.
 7060 
 7061      Meaning:  MSG  is an   error_table_ message.   A programming
 7062                error has been encountered.
 7063 
 7064      Action:   Contact the  system programming staff.   After the
 7065                problem   is   corrected,   repeat   the  bootload
 7066                operation.
 7067 
 7068 
 7069 
 7070                [as_request_server_.pl1]
 7071                as_request_server_:   ERROR_MESSAGE.   Can't  find
 7072                message from PGID
 7073 
 7074 
 7075      Stream:   as (severity0)
 7076 
 7077      Time:     While system is running.
 7078 
 7079      Meaning:  MSG  is  an  error_table_  message  and  PGID is a
 7080                process group id.  A process  sent a wakeup to the
 7081                Answering  Service, but did  not put a  message in
 7082                as_request.ms.
 7083 
 7084      Action:   No operator action is required.
 7085 
 7086 
 7087                [as_request_server_.pl1]
 7088 
 7089 
 7090 as_request_server_             123            08/21/20     MR12.7^L
 7091 
 7092 
 7093                as_request_server_:   Message {for  "REQUEST NAME"
 7094                (type N)} too short from PERS.PROJ.
 7095 
 7096 
 7097      Stream:   as (severity0)
 7098 
 7099      Time:     While system is running.
 7100 
 7101      Meaning:  A request of  type N sent by the  process group id
 7102                specified by PERS.PROJ was  in error.  The request
 7103                is  ignored.  If the  request is shorter  than the
 7104                standard   request  header   which  precedes   all
 7105                requests, then the request  type is not present in
 7106                the message.
 7107 
 7108      Action:   No operator action is required.
 7109 
 7110 
 7111                [as_request_server_.pl1]
 7112                as_request_server_:    MSG.   Process   no  longer
 7113                active for request from PERS.PROJ.
 7114 
 7115 
 7116      Stream:   as (severity0)
 7117 
 7118      Time:     While system is running.
 7119 
 7120      Meaning:  MSG is an error_table_ message and PERS.PROJ isthe
 7121                sender  id.   A  process  sent  a  wakeup  to  the
 7122                Answering Service  but then logged out  before the
 7123                Answering Service handled the wakeup.
 7124 
 7125      Action:   No operator action is required.
 7126 
 7127 
 7128                [as_request_server_.pl1]
 7129                as_request_server_:   MSG.  Error  reading message
 7130                from message segment.
 7131 
 7132 
 7133      Stream:   as (severity0)
 7134 
 7135      Time:     While system is running.
 7136 
 7137      Meaning:  MSG is an error_table_ message.  An error occurred
 7138                while  reading an AS  message from the  AS request
 7139                queue.
 7140 
 7141      Action:   No operator action is required.
 7142 
 7143 
 7144                [as_request_server_.pl1]
 7145 
 7146 
 7147 
 7148 as_request_server_             124            08/21/20     MR12.7^L
 7149 
 7150 
 7151                as_request_server_:   Rejected   invalid  type  XX
 7152                message from PERS.PROJ PID.
 7153 
 7154 
 7155      Stream:   as (severity0)
 7156 
 7157      Time:     While system is running.
 7158 
 7159      Meaning:  An  invalid  wakeup  request   has  been  sent  to
 7160                as_request_server_.   The  sending  process  ID is
 7161                PID,  and  the  sender  name  in  the  message  is
 7162                PERS.PROJ.  The request is  a type XX request.  No
 7163                action was taken.
 7164 
 7165      Action:   No operator action is required.
 7166 
 7167 
 7168                [as_request_server_.pl1]
 7169                as_request_server_:   Request message  segment not
 7170                initialized or shutdown has been typed.
 7171 
 7172 
 7173      Stream:   as (severity1)
 7174 
 7175      Time:     While system is running.
 7176 
 7177      Meaning:  A request is being  ignored because the AS request
 7178                queue has not been initialized or the the operator
 7179                has typed the shutdown command.
 7180 
 7181      Action:   No operator action is required.
 7182 
 7183 
 7184                [as_x25_mpx_.pl1]
 7185                as_x25_mpx_:  Bad argument to parm PARM, should be
 7186                THIS or THAT, but was VALUE for multiplexer MPX.
 7187 
 7188 
 7189      Stream:   as (severity1)
 7190 
 7191      Time:     In  response to  an operator  load_mpx command  or
 7192                during system start up.
 7193 
 7194      Meaning:  A  bad value was  specified for parameter  PARM in
 7195                the additional_info field of the TTF entry for the
 7196                multiplexer  MPX.  The  choices are  THIS or THAT,
 7197                but VALUE was specified.
 7198 
 7199      Action:   Check  the  contents  of  the  TTF  entry  for the
 7200                terminal_type associated with  the multiplexer for
 7201                an improper  parameter value.  Correct  and reload
 7202                mpx.
 7203 
 7204 
 7205 
 7206 as_x25_mpx_                    125            08/21/20     MR12.7^L
 7207 
 7208 
 7209 
 7210 
 7211                [as_x25_mpx_.pl1]
 7212                as_x25_mpx_:   Bad argument   to parm  PARM.  Must
 7213                have:  LOW  <= value <=  HIGH, but value  = VALUE,
 7214                for multiplexer MPX.
 7215 
 7216 
 7217      Stream:   as (severity1)
 7218 
 7219      Time:     In  response to  an operator  load_mpx command  or
 7220                during system start up.
 7221 
 7222      Meaning:  A  bad value was  specified for parameter  PARM in
 7223                the additional_info field of the TTF entry for the
 7224                multiplexer  MPX.  The  value must  be between LOW
 7225                and HIGH, but VALUE was specified.
 7226 
 7227      Action:   Check  the  contents  of  the  TTF  entry  for the
 7228                terminal_type associated with  the multiplexer for
 7229                an improper  parameter value.  Correct  and reload
 7230                mpx.
 7231 
 7232 
 7233 
 7234                [as_x25_mpx_.pl1]
 7235                as_x25_mpx_:  Crash signalled for multiplexer MPX.
 7236 
 7237 
 7238      Stream:   as (severity1)
 7239 
 7240      Time:     While system is running.
 7241 
 7242      Meaning:  The  multiplexer has  crashed.  The  LAP link  has
 7243                entered the disconnected state.
 7244 
 7245      Action:   Contact the system programming staff.
 7246 
 7247 
 7248                [as_x25_mpx_.pl1]
 7249                as_x25_mpx_:   Error  in  conversion.   Converting
 7250                FIELD VALUE to a number for multiplexer MPX.
 7251 
 7252 
 7253      Stream:   as (severity1)
 7254 
 7255      Time:     In  response to  an operator  load_mpx command  or
 7256                during system start up.
 7257 
 7258      Meaning:  It was  impossible to convert a  numeric parameter
 7259                from  the terminal_type additional_info  string to
 7260                its  internal  form.   FIELD  is  the  name of the
 7261 
 7262 
 7263 
 7264 as_x25_mpx_                    126            08/21/20     MR12.7^L
 7265 
 7266 
 7267                parameter  in error.   VALUE is  the string  which
 7268                could not be converted.
 7269 
 7270      Action:   Check  the  contents  of  the  TTF  entry  for the
 7271                terminal_type associated with  the multiplexer for
 7272                errors.
 7273 
 7274 
 7275 
 7276                [as_x25_mpx_.pl1]
 7277                as_x25_mpx_:   ERROR.  Cannot get  additional info
 7278                for terminal type TTP for multiplexer MPX.
 7279 
 7280 
 7281      Stream:   as (severity1)
 7282 
 7283      Time:     In  response to  an operator  load_mpx command  or
 7284                during system start up.
 7285 
 7286      Meaning:  An error occurred  while retrieving the parameters
 7287                of  the  multiplexer  from  the  TTT.   Either the
 7288                terminal type specified in  the CDT does not exist
 7289                or    it   does    not   contain    the   required
 7290                additional_info field.
 7291 
 7292      Action:   Check  that the  CMF  and  TTF contain  the proper
 7293                information.
 7294 
 7295 
 7296                [as_x25_mpx_.pl1]
 7297                as_x25_mpx_:   ERROR.  Creating event  channel for
 7298                multiplexer MPX.
 7299 
 7300 
 7301      Stream:   as (severity1)
 7302 
 7303      Time:     In  response to  an operator  load_mpx command  or
 7304                during system start up.
 7305 
 7306      Meaning:  An ipc_ error occurred  while trying to initialize
 7307                the multiplexer.
 7308 
 7309      Action:   Contact the system programming staff.
 7310 
 7311 
 7312                [as_x25_mpx_.pl1]
 7313                as_x25_mpx_:  Load failed for multiplexer MPX.
 7314 
 7315 
 7316      Stream:   as (severity1)
 7317 
 7318      Time:     In  response to  an operator  load_mpx command  or
 7319                during system start up.
 7320 
 7321 
 7322 as_x25_mpx_                    127            08/21/20     MR12.7^L
 7323 
 7324 
 7325      Meaning:  The attempt to load  the multiplexer failed.  This
 7326                should never happen.
 7327 
 7328      Action:   Contact the system programming staff.
 7329 
 7330 
 7331                [as_x25_mpx_.pl1]
 7332                as_x25_mpx_:  Load signalled for multiplexer MPX.
 7333 
 7334 
 7335      Stream:   as (severity1)
 7336 
 7337      Time:     In  response to  an operator  load_mpx command  or
 7338                during system start up.
 7339 
 7340      Meaning:  The multiplexer has  been successfully loaded.  It
 7341                will  be  started  unless  the  -no_start  control
 7342                argument was  given when the load_mpx  command was
 7343                typed.
 7344 
 7345      Action:   No operator action is required.
 7346 
 7347 
 7348                [as_x25_mpx_.pl1]
 7349                as_x25_mpx_:  MPX:  n_lc must be specified.
 7350 
 7351 
 7352      Stream:   as (severity1)
 7353 
 7354      Time:     In  response to  an operator  load_mpx command for
 7355                during system startup.
 7356 
 7357      Meaning:  The  TTF entry for  the X.25 multiplexer  does not
 7358                specify the number of logical channels.
 7359 
 7360      Action:   Correct the TTF and reload the multiplexer.
 7361 
 7362 
 7363                [as_x25_mpx_.pl1]
 7364                as_x25_mpx_:   Unexpected  signal   NUM  in  state
 7365                STATE.
 7366 
 7367 
 7368      Stream:   as (severity1)
 7369 
 7370      Time:     While system is running.
 7371 
 7372      Meaning:  A signal, NUM, was  received unexpectedly in state
 7373                STATE.  The signal is ignored.
 7374 
 7375      Action:   Contact the system programming staff.
 7376 
 7377 
 7378 
 7379 
 7380 as_x25_mpx_                    128            08/21/20     MR12.7^L
 7381 
 7382 
 7383                [as_x25_mpx_.pl1]
 7384                as_x25_mpx_:    Unexpected   wakeup   (DATA)  from
 7385                process PRCID.
 7386 
 7387 
 7388      Stream:   as (severity1)
 7389 
 7390      Time:     While system is running.
 7391 
 7392      Meaning:  The multiplexer manager received  a wakeup from an
 7393                unexpected source.  The wakeup is ignored.
 7394 
 7395      Action:   No operator action is required.
 7396 
 7397 
 7398                [as_x25_mpx_.pl1]
 7399                as_x25_mpx_:   Wakeup  for   multiplexer  MPX  has
 7400                invalid state code STATE.
 7401 
 7402 
 7403      Stream:   as (severity1)
 7404 
 7405      Time:     While system is running.
 7406 
 7407      Meaning:  A  wakeup with  invalid data  was received  by the
 7408                multiplexer manager.  The wakeup is ignored.
 7409 
 7410      Action:   Contact the system programming staff.
 7411 
 7412 
 7413                [asr_abs_command_server_.pl1]
 7414                asr_abs_command_server_:    Request  REQUEST   not
 7415                found, could not cancel for USER.
 7416 
 7417 
 7418      Stream:   as (severity0)
 7419 
 7420      Time:     While system is running.
 7421 
 7422      Meaning:  User USER  requested cancellation of  absentee job
 7423                REQUEST which did not exist.
 7424 
 7425      Action:   No operator action is required.
 7426 
 7427 
 7428                [asr_daemon_command_server_.pl1]
 7429                asr_daemon_command_server_:                 Denied
 7430                send_daemon_command for USER in ring RING.
 7431 
 7432 
 7433      Stream:   $sc
 7434 
 7435      Time:     While system is running.
 7436 
 7437 
 7438 asr_daemon_command_server_     129            08/21/20     MR12.7^L
 7439 
 7440 
 7441      Meaning:  User USER requested the system to execute a daemon
 7442                command,      but       lacked      access      to
 7443                >sc1>admin_acs>send_admin_command.acs    or    the
 7444                appropriate daemon source ACS.
 7445 
 7446      Action:   No operator action is required.
 7447 
 7448 
 7449                [asr_daemon_command_server_.pl1]
 7450                asr_daemon_command_server_:    Failed   to   check
 7451                access for USER.
 7452 
 7453 
 7454      Stream:   $sc
 7455 
 7456      Time:     While system is running.
 7457 
 7458      Meaning:  User USER requested the system to execute a daemon
 7459                command,  but   validate_daemon_commands  was  not
 7460                enabled and  the system could not  determine their
 7461                access to the send_daemon_command acs.
 7462 
 7463      Action:   No operator action is required.
 7464 
 7465 
 7466                [asr_daemon_command_server_.pl1]
 7467                asr_daemon_command_server_:  PERSON:  COMMAND INFO
 7468 
 7469 
 7470      Stream:   $sc
 7471 
 7472      Time:     While system is running.
 7473 
 7474      Meaning:  A system administrator has sent  a for a daemon to
 7475                the Initializer, which executes it.
 7476 
 7477      Action:   No operator action is required.
 7478 
 7479 
 7480                [astty_.pl1]
 7481                astty_:  ERROR_TABLE_MESSAGE CHANNEL has undefined
 7482                terminal type TERM_TYPE for set_term_type order.
 7483 
 7484 
 7485      Stream:   as (severity 0) or $as1
 7486 
 7487      Time:     While system is running.
 7488 
 7489      Meaning:  The  system received the  ERROR_TABLE_MESSAGE when
 7490                an attempt  was made to  set the terminal  type of
 7491                CHANNEL to  TERM_TYPE.  Suspect the  terminal type
 7492                is not known on  to the system.  The set_term_type
 7493                control order was ignored.
 7494 
 7495 
 7496 astty_                         130            08/21/20     MR12.7^L
 7497 
 7498 
 7499      Action:   Contact the system programming staff.
 7500 
 7501 
 7502                [astty_.pl1]
 7503                astty_:  ERROR_TABLE_MESSAGE CHANNEL NN TEXT
 7504 
 7505 
 7506      Stream:   as (severity 0) or $as1
 7507 
 7508      Time:     While system is running.
 7509 
 7510      Meaning:  This  is tracing  or error  logging output.   This
 7511                output may appear in the  AS log, or be printed on
 7512                the severity1  stream as directed by  astty_ trace
 7513                and log_error requests described below.
 7514 
 7515      Action:   No  operator  action  is  required.   Tracing  and
 7516                logging  is controlled  by the  following entries,
 7517                which may be typed as commands in admin mode.
 7518                astty_$trace  -  causes  tracing  of  all calls to
 7519                astty_
 7520                astty_$notrace - disables tracing
 7521                astty_$log_error -  logs calls to astty_  that get
 7522                errors.  does not print.
 7523                astty_$log_error_1  -  logs  and  prints  calls to
 7524                astty_ that get errors.
 7525                astty_$no_log_error - disables error logging.
 7526 
 7527 
 7528 
 7529                [astty_.pl1]
 7530                astty_:     ERROR_TABLE_MESSAGE    CHANNEL    SSSS
 7531                line_status failed after line_status_pending
 7532 
 7533 
 7534      Stream:   as (severity 0) or $as1
 7535 
 7536      Time:     While system is running.
 7537 
 7538      Meaning:  System  received the  ERROR_TABLE_MESSAGE when  it
 7539                tried to do a line status control order on CHANNEL
 7540                in    state    SSSS    after    it    received   a
 7541                line_status_pending  error code.   The error  code
 7542                for ERROR_TABLE_MESSAGE  was returned back  to the
 7543                caller.
 7544 
 7545      Action:   Contact the system programming staff.
 7546 
 7547 
 7548                [astty_.pl1]
 7549                astty_:  ERROR_TABLE_MESSAGE CHANNEL  state SSSS >
 7550                TTY_HUNG on hung-up error code.
 7551 
 7552 
 7553 
 7554 astty_                         131            08/21/20     MR12.7^L
 7555 
 7556 
 7557      Stream:   as (severity 0) or $as1
 7558 
 7559      Time:     While system is running.
 7560 
 7561      Meaning:  An error code  of ERROR_TABLE_MESSAGE was returned
 7562                while   servicing  CHANNEL  indicating   that  the
 7563                channel is  not useable.  However, the  state SSSS
 7564                of  the  channel  indicates  that  the channel was
 7565                active,  thus the  CHANNEL state  is inconsistant.
 7566                The channel will be hungup.
 7567 
 7568      Action:   Contact the system programming staff.
 7569 
 7570 
 7571                [astty_.pl1]
 7572                astty_:  ERROR_TABLE_MESSAGE  error attaching IOCB
 7573                for channel CCCC.
 7574 
 7575 
 7576      Stream:   as (severity 0) or $as1
 7577 
 7578      Time:     While system is running.
 7579 
 7580      Meaning:  The   system   received   the  ERROR_TABLE_MESSAGE
 7581                attempting  to  attach  to  channel  CCCC using an
 7582                IOCB.  The channel was then hungup.
 7583 
 7584      Action:   Contact the system programming staff.
 7585 
 7586 
 7587                [astty_.pl1]
 7588                astty_:  ERROR_TABLE_MESSAGE error finding an IOCB
 7589                for channel CCCC.
 7590 
 7591 
 7592      Stream:   as (severity 0) or $as1
 7593 
 7594      Time:     While system is running.
 7595 
 7596      Meaning:  The  system received the  ERROR_TABLE_MESSAGE when
 7597                it  attempted to  find an  IOCB for  channel CCCC.
 7598                The channel was then hungup.
 7599 
 7600      Action:   Contact the system programming staff.
 7601 
 7602 
 7603                [astty_.pl1]
 7604                astty_:   ERROR_TABLE_MESSAGE  error  opening IOCB
 7605                for channel CCCC.
 7606 
 7607 
 7608      Stream:   as (severity 0) or $as1
 7609 
 7610 
 7611 
 7612 astty_                         132            08/21/20     MR12.7^L
 7613 
 7614 
 7615      Time:     While system is running.
 7616 
 7617      Meaning:  The   system   received   the   ERROR_TALE_MESSAGE
 7618                attemping to open the  channel CCCC using an IOCB.
 7619                The channel was then hungup.
 7620 
 7621      Action:   Contact the system programming staff.
 7622 
 7623 
 7624                [astty_.pl1]
 7625                astty_:  tty_state returned  SSSS for hung-up line
 7626                CHANNEL.
 7627 
 7628 
 7629      Stream:   as (severity 0) or $as1
 7630 
 7631      Time:     While system is running.
 7632 
 7633      Meaning:  In processing  the astty_$tty_state entry,  a call
 7634                to hcs_$tty_state  returned a state value  of SSSS
 7635                for  hung-up  CHANNEL  which  indicates  that  the
 7636                channel  is active.   However, the  returned error
 7637                code indicated  that the channel is  hung-up.  The
 7638                channel will be hungup.
 7639 
 7640      Action:   Contact the system programming staff.
 7641 
 7642 
 7643                [asu_.pl1]
 7644                asu_$release_ate:  bad cdte.process (LOCATION) for
 7645                CHANNEL
 7646 
 7647 
 7648      Stream:   as (severity 0)
 7649 
 7650      Time:     While system is running.
 7651 
 7652      Meaning:  This indicates a logic error in the supervisor, or
 7653                CPU  or memory  hardware problems.   When asked to
 7654                release   a  User   Table  Entry   (UTE)  for   an
 7655                interactive  process,   the  cdte.process  pointer
 7656                (LOCATION)  did not  point into  the answer table.
 7657                The UTE was not released.
 7658 
 7659      Action:   No operator action is required.
 7660 
 7661 
 7662                [asu_.pl1]
 7663                asu_$release_suspended_process:     PERSON.PROJECT
 7664                CHANNEL is not suspended
 7665 
 7666 
 7667      Stream:   as (severity 0)
 7668 
 7669 
 7670 asu_$release_suspended_process 133            08/21/20     MR12.7^L
 7671 
 7672 
 7673      Time:     Called  in response  to an  operator "abs release"
 7674                command, or in response  to a user reconnecting to
 7675                an interactive process.
 7676 
 7677      Meaning:  One  of   the  process  termination   handlers  is
 7678                incorrectly calling to release  a process which is
 7679                not currently suspended.
 7680 
 7681      Action:   No operator action is required.
 7682 
 7683 
 7684                [asu_.pl1]
 7685                asu_$remote_cdte:   ERROR_MESSAGE.   cdte  CCC|XXX
 7686                error from tty_state
 7687 
 7688 
 7689      Stream:   as (severity0)
 7690 
 7691      Time:     While system is running.
 7692 
 7693      Meaning:  Remove_cdte is trying to get rid of a channel.  It
 7694                cannot obtain the line state.
 7695 
 7696      Action:   No operator action is required.
 7697 
 7698 
 7699                [asu_.pl1]
 7700                asu_$suspend_process:   PERSON.PROJECT CHANNEL  is
 7701                already suspended
 7702 
 7703 
 7704      Stream:   as (severity 1)
 7705 
 7706      Time:     asu_$suspend_process  was  called  by  one  of the
 7707                process   termination  handlers   to  suspend   an
 7708                interactive  process whose  terminal disconnected,
 7709                or to suspend an absentee process via the operator
 7710                "abs suspend" command.
 7711 
 7712      Meaning:  The  process is   already suspended.   The current
 7713                request will be ignored.
 7714 
 7715      Action:   No operator action is required.
 7716 
 7717 
 7718                [asu_.pl1]
 7719                asu_:  attach channel not done on CHANNEL; service
 7720                type = TYPE
 7721 
 7722 
 7723      Stream:   as (severity 0)
 7724 
 7725      Time:     When attaching channels to the Answering Service.
 7726 
 7727 
 7728 asu_                           134            08/21/20     MR12.7^L
 7729 
 7730 
 7731      Meaning:  The CHANNEL was found in an inactive state (TYPE =
 7732                INACTIVE),  or  was  found  to  be  a  multiplexer
 7733                channel   (TYPE  =   MULTIPLEXER).   It   was  not
 7734                attached.This  indicates  a  logic  error  in  the
 7735                supervisor, or CPU or memory hardware problems.
 7736 
 7737      Action:   No operator action is required.
 7738 
 7739 
 7740                [asu_.pl1]
 7741                asu_:  listen not done on CHANNEL; current service
 7742                type = TYPE
 7743 
 7744 
 7745      Stream:   as (severity 0)
 7746 
 7747      Time:     When the Answering Service  tried to listen to the
 7748                channel.
 7749 
 7750      Meaning:  The CHANNEL was found in an inactive state (TYPE =
 7751                INACTIVE), was  found to be a  multiplexer channel
 7752                (TYPE =  MULTIPLEXER), was found  to be in  use by
 7753                the message coordinator (TYPE  = MC), or was found
 7754                to be attached for Testing and Diagnostics (TYPE =
 7755                TANDD_SERVICE).   The  attempt  to  listen  on the
 7756                channel failed.This indicates a logic error in the
 7757                supervisor, or CPU or memory hardware problems.
 7758 
 7759      Action:   No operator action is required.
 7760 
 7761 
 7762                [asu_.pl1]
 7763                asu_:  (called by PROCEDURE)  USER PROJ CHN is not
 7764                stopped (state = S) even  though destroy flag = D;
 7765                it might not be possible to destroy this process
 7766 
 7767 
 7768 
 7769      Stream:   as (severity1)
 7770 
 7771      Time:     In response to an operator  command to bump or log
 7772                out an interactive, absentee, or daemon user.
 7773 
 7774      Meaning:  The process  being bumped or logged  out was found
 7775                to be partially logged out already, but not in the
 7776                stopped state.  An attempt will be made to destroy
 7777                this process, but it might fail.
 7778 
 7779      Action:   Contact the system programming staff.
 7780 
 7781 
 7782                [asu_.pl1]
 7783                asu_:   (called by   PROCEDURE) USER.PROJ  CHN was
 7784 
 7785 
 7786 asu_                           135            08/21/20     MR12.7^L
 7787 
 7788 
 7789                already  stopped and  will be  destroyed (stopstop
 7790                wakeup was lost)
 7791 
 7792 
 7793      Stream:   as (severity1)
 7794 
 7795      Time:     In response to an operator  command to bump or log
 7796                out an interactive, absentee, or daemon user.
 7797 
 7798      Meaning:  The process  being bumped or logged  out was found
 7799                to be in the stopped state (partially logged out).
 7800                A  wakeup  from  ring  zero  indicating  that  the
 7801                process  was stopped  and could  be destroyed  was
 7802                apparently lost.  Destruction  of the process will
 7803                be completed.
 7804 
 7805      Action:   Contact the system programming staff.
 7806 
 7807 
 7808                [asu_.pl1]
 7809                asu_:  cdte CCC|XXX (CHANNEL) hung up
 7810 
 7811 
 7812      Stream:   as (severity0)
 7813 
 7814      Time:     While system is running.
 7815 
 7816      Meaning:  Remove_cdte  is trying  to get  rid of  a channel.
 7817                The indicated CHANNEL is in the hung up state.
 7818 
 7819      Action:   No operator action is required.
 7820 
 7821 
 7822                [asu_.pl1]
 7823                asu_:  cdte CCC|XXX (CHANNEL) state A in use B tra
 7824                vec C
 7825 
 7826 
 7827      Stream:   as (severity0)
 7828 
 7829      Time:     While system is running.
 7830 
 7831      Meaning:  Remove_cdte is trying to get rid of a channel.  It
 7832                first logs the state of the line.
 7833 
 7834      Action:   No operator action is required.
 7835 
 7836 
 7837                [asu_.pl1]
 7838                asu_:  cdtep (CCC|ZZZ) not cdt (YYY|0)
 7839 
 7840 
 7841      Stream:   as (severity0)
 7842 
 7843 
 7844 asu_                           136            08/21/20     MR12.7^L
 7845 
 7846 
 7847      Time:     While system is running.
 7848 
 7849      Meaning:  This indicates a logic error in the supervisor, or
 7850                CPU or  memory hardware problems.   Remove_cdte is
 7851                trying to get rid of a channel which is no good.
 7852 
 7853      Action:   No operator action is required.
 7854 
 7855 
 7856                [asu_.pl1]
 7857                asu_:   CHANNEL  cannot  be  attached  because its
 7858                service type is TYPE (N).
 7859 
 7860 
 7861      Stream:   as (severity1)
 7862 
 7863      Time:     While system is running.
 7864 
 7865      Meaning:  An  attach  command   specified  a  CHANNEL  whose
 7866                service  type does not  permit it to  be attached.
 7867                No action was taken.
 7868 
 7869      Action:   Enter a correct command.
 7870 
 7871 
 7872                [asu_.pl1]
 7873                asu_:    CHANNEL  has   been  deleted   by  a  CDT
 7874                installation and so cannot be attached.
 7875 
 7876 
 7877 
 7878      Stream:   as (severity1)
 7879 
 7880      Time:     While system is running.
 7881 
 7882      Meaning:  An  attach command  specified a  CHANNEL that  has
 7883                been deleted.  No action was taken.
 7884 
 7885      Action:   Enter a correct command.
 7886 
 7887 
 7888                [asu_.pl1]
 7889                asu_:  CHANNEL has in_use =  N, current state = S,
 7890                {CDTE.state was OS}
 7891 
 7892 
 7893      Stream:   as (severity 1)
 7894 
 7895      Time:     When the operator attempts to attach the channel.
 7896 
 7897      Meaning:  The  Channel  Definition  Table  (CDT)  entry  for
 7898                CHANNEL   is  in   an  inconsistent   state.   See
 7899                dialup_values.incl.pl1  for a  description of  the
 7900 
 7901 
 7902 asu_                           137            08/21/20     MR12.7^L
 7903 
 7904 
 7905                in_use and  state values.  The old  state value OS
 7906                is displayed  only if it differs  from the current
 7907                state.
 7908 
 7909      Action:   Enter a corrected command line.
 7910 
 7911 
 7912                [asu_.pl1]
 7913                asu_:  CHANNEL in use  as a multiplexer and cannot
 7914                be attached.
 7915 
 7916 
 7917      Stream:   as (severity 0)
 7918 
 7919      Time:     When  issuing  an  operator  attach  command for a
 7920                channel.
 7921 
 7922      Meaning:  CHANNEL is operating  as a multiplexer, supporting
 7923                one  or  more  channels.   It  cannot  be attached
 7924                directly.  The attach operation fails.
 7925 
 7926      Action:   Enter a corrected command line.
 7927 
 7928 
 7929                [asu_.pl1]
 7930                asu_:   CHANNEL in  use for  T &  D and  cannot be
 7931                attached.
 7932 
 7933 
 7934      Stream:   as (severity1)
 7935 
 7936      Time:     While system is running.
 7937 
 7938      Meaning:  An  operator attach   command specified  a CHANNEL
 7939                being  tested via   Test and  Diagnostic routines.
 7940                The channel was not attached.
 7941 
 7942      Action:   Enter a corrected command line.
 7943 
 7944 
 7945                [asu_.pl1]
 7946                asu_:   CHANNEL  is  a  multiplexer  and cannot be
 7947                removed.
 7948 
 7949 
 7950      Stream:   as (severity 1)
 7951 
 7952      Time:     When the operator attempts to remove a channel.
 7953 
 7954      Meaning:  CHANNEL  is a   multiplexer channel  which handles
 7955                data   for   one   or   more   subchannels.   Such
 7956                multiplexers  are not   attached by  the Answering
 7957                Service, and therefore cannot be removed.
 7958 
 7959 
 7960 asu_                           138            08/21/20     MR12.7^L
 7961 
 7962 
 7963      Action:   Enter a corrected command line.
 7964 
 7965                Message:       asu_$bump_user:      ERROR_MESSAGE.
 7966                BLAST_MESSAGE.     Sending   blast    message   to
 7967                PERSON.PROJECT on CHANNEL
 7968 
 7969      Stream:   as (severity 0)
 7970 
 7971      Time:     While system is running.
 7972 
 7973      Meaning:  An  error  occurred  while  attempting  to send an
 7974                operator  warning  message  to  PERSON.PROJECT  on
 7975                CHANNEL.   ERROR_MESSAGE  is  the  text associated
 7976                with the  error which occurred.   BLAST_MESSAGE is
 7977                the undelivered operator warning.
 7978 
 7979      Action:   No operator action is required.
 7980 
 7981 
 7982                [asu_.pl1]
 7983                asu_:   CHANNEL is  already attached;  will try to
 7984                listen to it again
 7985 
 7986 
 7987      Stream:   as (severity 1)
 7988 
 7989      Time:     When the operator attempts to attach a channel.
 7990 
 7991      Meaning:  The CHANNEL was already  attached by the Answering
 7992                Service,  but was  not dialed  up.  The  Answering
 7993                Service will attempt to  listen for dialups on the
 7994                channel.
 7995 
 7996      Action:   Enter a corrected command line.
 7997 
 7998 
 7999                [asu_.pl1]
 8000                asu_:    CHANNEL  is   in  use   by  the   message
 8001                coordinator and cannot be attached.
 8002 
 8003 
 8004      Stream:   as (severity1)
 8005 
 8006      Time:     While system is running.
 8007 
 8008      Meaning:  An  operator attach   command specified  a message
 8009                coordinator   CHANNEL.    The   channel   was  not
 8010                attached.
 8011 
 8012      Action:   Enter a correct command.
 8013 
 8014 
 8015                [asu_.pl1]
 8016 
 8017 
 8018 asu_                           139            08/21/20     MR12.7^L
 8019 
 8020 
 8021                asu_:   CHANNEL is  not in  CDT and  so cannot  be
 8022                attached
 8023 
 8024 
 8025      Stream:   as (severity1)
 8026 
 8027      Time:     While system is running.
 8028 
 8029      Meaning:  An  attach command  specified an  unknown CHANNEL.
 8030                No action was taken.
 8031 
 8032      Action:   Enter a correct command.
 8033 
 8034 
 8035                [asu_.pl1]
 8036                asu_:   CHANNEL  was  not  configured  at bootload
 8037                time, and so cannot be attached.
 8038 
 8039 
 8040 
 8041      Stream:   as (severity1)
 8042 
 8043      Time:     While system is running.
 8044 
 8045      Meaning:  An attach command specified  a CHANNEL that cannot
 8046                be  used until the  next bootload.  No  action was
 8047                taken.
 8048 
 8049      Action:   Enter a correct command.
 8050 
 8051 
 8052                [asu_.pl1]
 8053                asu_:  ENTRYPOINT called with null UTE ptr.
 8054 
 8055 
 8056      Stream:   as (severity0)
 8057 
 8058      Time:     ENTRYPOINT     may    be     suspend_process    or
 8059                setup_login_server_handle.    suspend_process  was
 8060                called by one of  the process termination handlers
 8061                to suspend  an interactive process  whose terminal
 8062                disconnected,  or to  suspend an  absentee process
 8063                via   the   operator    "abs   suspend"   command.
 8064                setup_login_server_handler was  called in response
 8065                to  a  validate,  connect,  new_proc,  or  destroy
 8066                request from a login server.
 8067 
 8068      Meaning:  Programming  error  in   the  process  termination
 8069                handlers,  or  the  login  server  support  of the
 8070                Answering Service.
 8071 
 8072      Action:   Contact the system programming staff.
 8073 
 8074 
 8075 
 8076 asu_                           140            08/21/20     MR12.7^L
 8077 
 8078 
 8079 
 8080 
 8081                [asu_.pl1]
 8082                asu_:  ERROR_MESSAGE.  ENTRY OPERATION error; will
 8083                remove channel CHANNEL DESC
 8084 
 8085 
 8086 
 8087      Stream:   as (severity1)
 8088 
 8089      Time:     While system is running.
 8090 
 8091      Meaning:  A channel error has  occurred on CHANNEL.  DESC is
 8092                the  comment field  for the  channel given  in its
 8093                Channel    Definition     Table    (CDT)    entry.
 8094                ERROR_MESSAGE gives the  text describing the error
 8095                code  returned  by   the  operation  in  progress.
 8096                OPERATION       may        be       create_ev_chn,
 8097                decl_event_call_chn,     listen,    set_term_type,
 8098                tty_event   or  tty_index,   dependent  upon   the
 8099                operation  in progress   when the  error occurred.
 8100                ENTRY  specifies  the  asu_  entrypoint  that  was
 8101                running  when the  operation was  performed on the
 8102                channel.  It may  be asu_listen or attach_channel.
 8103                The channel will be removed from use.
 8104 
 8105      Action:   It may be necessary to  busy out the modem for the
 8106                channel.
 8107 
 8108 
 8109                [asu_.pl1]
 8110                asu_:   ERROR_MESSAGE.  Sending initial  wakeup to
 8111                PROCESS_ID (PERSON.PROJECT)
 8112 
 8113 
 8114      Stream:   as (severity 0)
 8115 
 8116      Time:     Called  at process  creation to  start the process
 8117                running.
 8118 
 8119      Meaning:  ERROR_MESSAGE  is  the  text  of  an  error  which
 8120                occurred   attempting   to   send   a   wakeup  to
 8121                PERSON.PROJECT.   As  a   result  of  this  error,
 8122                process creation will fail.
 8123 
 8124      Action:   No operator action is required.
 8125 
 8126 
 8127                [asu_.pl1]
 8128                asu_:   ERROR_MESSAGE.  Retrieving  the values  of
 8129                R-0ffset     and    R-Factor     for    PROCESS_ID
 8130                (PERSON.PROJECT).
 8131 
 8132 
 8133 
 8134 asu_                           141            08/21/20     MR12.7^L
 8135 
 8136 
 8137      Stream:   as (severity 0)
 8138 
 8139      Time:     Called at process creation.
 8140 
 8141      Meaning:  asu_$start_process called hphcs_$get_ipc_operands.
 8142                This call failed with an error whose text is shown
 8143                as ERROR_MESSAGE.   As a result, the  process will
 8144                not be started.
 8145 
 8146      Action:   No operator action is required.
 8147 
 8148 
 8149                [asu_.pl1]
 8150                asu_:  listen failed on CHANNEL:  state = N
 8151 
 8152 
 8153      Stream:   as (severity 0)
 8154 
 8155      Time:     When  attempting  to  listen  for  dialups  on the
 8156                channel.
 8157 
 8158      Meaning:  The  Channel  Definition  Table  (CDT)  entry  for
 8159                CHANNEL  has an  invalid state  value N.   Channel
 8160                listening will not occur.
 8161 
 8162      Action:   No operator action is required.
 8163 
 8164 
 8165                [asu_.pl1]
 8166                asu_:   listen not  done on  CHANNEL:  IN_USE with
 8167                state  =   STATE,  in_use  =  IN_USE,   tra_vec  =
 8168                CURRENT_OPERATION
 8169 
 8170 
 8171 
 8172      Stream:   as (severity 0)
 8173 
 8174      Time:     When the Answering Service  tries to listen to the
 8175                channel.
 8176 
 8177      Meaning:  The  Channel  Definition  Table  (CDT)  entry  for
 8178                CHANNEL   is  in   an  inconsistent   state.   See
 8179                dialup_values.incl.pl1  for a  description of  the
 8180                state, in_use and tra_vec values.
 8181 
 8182      Action:   No operator action is required.
 8183 
 8184 
 8185                [asu_.pl1]
 8186                asu_:  lock  was N, ev  call mask was  M, ips mask
 8187                was ZZZZZZ
 8188 
 8189 
 8190 
 8191 
 8192 asu_                           142            08/21/20     MR12.7^L
 8193 
 8194 
 8195      Stream:   as (severity1)
 8196 
 8197      Time:     In response to an operator reset command.
 8198 
 8199      Meaning:  N  is the  value  of  anstbl.lock_value, M  is the
 8200                value of  event call masking.  ZZZZZZ  was the ips
 8201                mask.   This  message   verifies  that  the  reset
 8202                command was given, and what effect it had.
 8203 
 8204      Action:   No operator action is required.
 8205 
 8206 
 8207                [asu_.pl1]
 8208                asu_:  MESSAGE.  unable to unmask channel CHANNEL.
 8209 
 8210 
 8211      Stream:   as (severity1)
 8212 
 8213      Time:     In  response to  an operator  command to  attach a
 8214                channel which had been masked by MCS.
 8215 
 8216      Meaning:  The CHANNEL could not be unmasked.
 8217 
 8218      Action:   Contact the system programming staff.
 8219 
 8220 
 8221                [asu_.pl1]
 8222                asu_:  Unable to create  event channel for new UTE
 8223                LOCATION
 8224 
 8225 
 8226      Stream:   as (severity 2)
 8227 
 8228      Time:     While system is running.
 8229 
 8230      Meaning:  This indicates a logic error in the supervisor, or
 8231                CPU or memory hardware problems.
 8232 
 8233      Action:   Contact the system programming staff.
 8234 
 8235 
 8236                [asu_.pl1]
 8237                asu_:  unmasking channel CHANNEL.
 8238 
 8239 
 8240      Stream:   as (severity1)
 8241 
 8242      Time:     In  response to  an operator  command to  attach a
 8243                channel which has been masked by MCS.
 8244 
 8245      Meaning:  A  special  order  is  issued  to  MCS  to  unmask
 8246                CHANNEL, and the channel  should then be available
 8247                for regular use.
 8248 
 8249 
 8250 asu_                           143            08/21/20     MR12.7^L
 8251 
 8252 
 8253      Action:   No operator action is required.
 8254 
 8255 
 8256                [asum_inner_ring_caller_.pl1]
 8257                asum_inner_ring_caller_:    ASUM  database   found
 8258                locked after return from call by GROUP_ID
 8259 
 8260 
 8261 
 8262      Stream:   BOS Typewriter.
 8263 
 8264      Time:     While system is running.
 8265 
 8266      Meaning:  This indicates a logic error in the supervisor, or
 8267                CPU  or  memory  hardware  problems.   The AS user
 8268                message facility  was called and upon  return from
 8269                the      call       the      transfer      routine
 8270                asum_inner_ring_caller_  detected  that  the  ASUM
 8271                database
 8272                (>sc1>user_messages>as_user_message_system)    was
 8273                left locked.   The lock has been  unlocked but the
 8274                database may  be inconsistent.  This  should never
 8275                happen and if it does, indicates a coding error in
 8276                the AS user message facility.
 8277 
 8278      Action:   Contact the system programming staff.
 8279 
 8280 
 8281                [operator_com_channel_cmds_.pl1]
 8282                attach:  Action not performed.  ttyXXX
 8283 
 8284 
 8285      Stream:   as (severity1).
 8286 
 8287      Time:     In response to an operator attach command.
 8288 
 8289      Meaning:  This is  the response to attach TTYxxx  if no more
 8290                room is available in  the answer table for channel
 8291                entries.  The line is not attached.
 8292 
 8293      Action:   Contact the system programming staff.
 8294 
 8295 
 8296                [operator_com_channel_cmds_.pl1]
 8297                attach:  bad arg "AAAA"
 8298 
 8299 
 8300      Stream:   as (severity1).
 8301 
 8302      Time:     In response to an operator command.
 8303 
 8304      Meaning:  A  bad  argument  was  furnished  with  an  attach
 8305                command.  The argument is skipped.
 8306 
 8307 
 8308 attach                         144            08/21/20     MR12.7^L
 8309 
 8310 
 8311      Action:   Enter a corrected command.
 8312 
 8313 
 8314                [operator_com_channel_cmds_.pl1]
 8315                attach:  error:  not done
 8316 
 8317 
 8318      Stream:   as (severity1).
 8319 
 8320      Time:     In response to an operator command.
 8321 
 8322      Meaning:  Bad arguments were given to an attach command.  No
 8323                action resulted.
 8324 
 8325      Action:   Enter a corrected command line.
 8326 
 8327 
 8328                [operator_com_channel_cmds_.pl1]
 8329                attach:  TTYxxx attached
 8330 
 8331 
 8332      Stream:   as (severity1).
 8333 
 8334      Time:     In response to an operator attach command.
 8335 
 8336      Meaning:  This is the response  to an attach TTYxxx command.
 8337                The  device  channel  is   now  connected  to  the
 8338                Answering Service and ready for dialups.
 8339 
 8340      Action:   No operator action is required.
 8341 
 8342 
 8343                [terminate_proc.pl1]
 8344                attempt to terminate an idle process
 8345 
 8346 
 8347      Stream:   BOS Typewriter (Crashes system)
 8348 
 8349      Time:     While system is running.
 8350 
 8351      Meaning:  This indicates a logic error in the supervisor, or
 8352                CPU or memory hardware problems.
 8353 
 8354      Action:   Follow normal recovery procedures.
 8355 
 8356 
 8357                [terminate_proc.pl1]
 8358                attempt to terminate initializer process
 8359 
 8360 
 8361      Stream:   BOS Typewriter (Crashes system)
 8362 
 8363      Time:     While system is running.
 8364 
 8365 
 8366 attempt                        145            08/21/20     MR12.7^L
 8367 
 8368 
 8369      Meaning:  This indicates a logic error in the supervisor, or
 8370                CPU or memory hardware problems.
 8371 
 8372      Action:   Follow normal recovery procedures.
 8373 
 8374 
 8375                [terminate_proc.pl1]
 8376                attempt to terminate process with TYPE lock set
 8377 
 8378 
 8379      Stream:   BOS Typewriter (Crashes system)
 8380 
 8381      Time:     While system is running.
 8382 
 8383      Meaning:  This indicates a logic error in the supervisor, or
 8384                CPU or memory hardware problems.
 8385 
 8386      Action:   Follow normal recovery procedures.
 8387 
 8388 
 8389                [access_audit_util_.pl1]
 8390                AUDIT (access_audit_util_):   GRANTED modification
 8391                of process audit flags ADDED_INFO
 8392 
 8393 
 8394      Stream:   $access_audit
 8395 
 8396      Time:     While system is running.
 8397 
 8398      Meaning:  The  specified  user   has  invoked  a  privileged
 8399                operation to change the process audit flags.  This
 8400                may result in more or less audit messages for that
 8401                user.
 8402 
 8403      Action:   Contact the system programming staff._ssa
 8404 
 8405 
 8406                [access_class_check.pl1]
 8407                AUDIT (access_class_check):   GRANTED modification
 8408                of security out_of_service ADDED_INFO
 8409 
 8410 
 8411      Stream:   $access_audit
 8412 
 8413      Time:     While system is running.
 8414 
 8415      Meaning:  The  soos switch for  the specified path  has been
 8416                turned on or off  by the security administrator as
 8417                indicated.
 8418 
 8419      Action:   No operator action is required.
 8420 
 8421 
 8422 
 8423 
 8424 AUDIT (create_vtoce)           146            08/21/20     MR12.7^L
 8425 
 8426 
 8427                [create_vtoce.pl1]
 8428                AUDIT  (create_vtoce):   DENIED  creation  of file
 8429                system object ADDED_INFO entry class range outside
 8430                LV (CLASS_RANGE lvid LVID)
 8431 
 8432 
 8433      Stream:   $access_audit
 8434 
 8435      Time:     While system is running.
 8436 
 8437      Meaning:  The specified  user attempted to create  a segment
 8438                whose access  class is outside the  range accepted
 8439                by the logical volume.
 8440 
 8441      Action:   Contact the system programming staff._ssa
 8442 
 8443 
 8444                [fim.alm]
 8445                AUDIT  (fim):   access   violation  fault  -  mode
 8446                ADDED_INFO
 8447 
 8448 
 8449 
 8450      Stream:   $access_audit
 8451 
 8452      Time:     While system is running.
 8453 
 8454      Meaning:  The  specified process   took an  access violation
 8455                fault "  because the access mode  was inconsistant
 8456                with the operation.
 8457 
 8458      Action:   No operator action is required.
 8459 
 8460 
 8461                [fim.alm]
 8462                AUDIT  (fim):   access   violation  fault  -  ring
 8463                ADDED_INFO
 8464 
 8465 
 8466 
 8467      Stream:   $access_audit
 8468 
 8469      Time:     While system is running.
 8470 
 8471      Meaning:  The  specified process   took an  access violation
 8472                fault " due to ring brackets inconsistant with the
 8473                operation.
 8474 
 8475      Action:   No operator action is required.
 8476 
 8477 
 8478                [fim.alm]
 8479                AUDIT (fim):  illegal procedure fault ADDED_INFO
 8480 
 8481 
 8482 AUDIT (fim)                    147            08/21/20     MR12.7^L
 8483 
 8484 
 8485      Stream:   $access_audit
 8486 
 8487      Time:     While system is running.
 8488 
 8489      Meaning:  The  specified process  took an  illegal procedure
 8490                fault.
 8491 
 8492      Action:   No operator action is required.
 8493 
 8494 
 8495                [mseg_message_.pl1]
 8496                Audit  (mseg_$add_message):  DENIED addition  of a
 8497                message to  a message segment  ADDED_INFO <Message
 8498                segment is full.>
 8499 
 8500 
 8501 
 8502      Stream:   $access_audit
 8503 
 8504      Time:     While system is running.
 8505 
 8506      Meaning:  A message  was not added  to a mailbox  or message
 8507                segment because  there is not enough  room for the
 8508                message  in the  segment.  Repeated  occurences of
 8509                this  event  over  a  short  period  of time could
 8510                indicate   an  attempt   to  exploit   a  moderate
 8511                bandwidth   covert   channel.    ADDED_INFO   will
 8512                identify the user and segment in question.
 8513 
 8514      Action:   Contact the system programming staff._ssa
 8515 
 8516 
 8517                [mseg_segment_.pl1]
 8518                Audit   (mseg_$reset_salvaged_flag_seg):   GRANTED
 8519                modifying  message  segment  attributes ADDED_INFO
 8520                <Message segment salvage flag reset.>
 8521 
 8522 
 8523 
 8524      Stream:   $access_audit
 8525 
 8526      Time:     While system is running.
 8527 
 8528      Meaning:  The  salvaged indicator  of a  message segment  or
 8529                mailbox was reset at the user's request.  Repeated
 8530                occurences  of this event  over a short  period of
 8531                time  could  indicate  an  attempt  to  exploit  a
 8532                moderate  bandwidth  covert  channel.   ADDED_INFO
 8533                will identify the user and segment in question.
 8534 
 8535      Action:   Contact the system programming staff._ssa
 8536 
 8537 
 8538 
 8539 
 8540 Audit (mseg_check_access_)     148            08/21/20     MR12.7^L
 8541 
 8542 
 8543 
 8544 
 8545                [mseg_check_access_.pl1]
 8546                Audit  (mseg_check_access_):   [GRANTED  | DENIED]
 8547                OPERATION_DESCRIPTION ADDED_INFO
 8548 
 8549 
 8550      Stream:   $access_audit
 8551 
 8552      Time:     While system is running.
 8553 
 8554      Meaning:  An  access control decision  has been made  by the
 8555                mseg_   primitives.    The   OPERATION_DESCRIPTION
 8556                specifies  the operation   requested by  the user.
 8557                GRANTED  or DENIED   indicates whether  access was
 8558                granted or not.  the ADDED_INFO describes the user
 8559                and   the  message    segment  or   mailbox.   The
 8560                associated  binary info  describes the  message in
 8561                the segment if a specific message was involved.
 8562 
 8563      Action:   Contact the system programming staff._ssa
 8564 
 8565 
 8566                [page_error.alm]
 8567                AUDIT  (page_fault):   GRANTED  excessive  segment
 8568                state  changes (Moderate_cc)  for PROCESS_GROUP_ID
 8569                (AUTHORIZATION)
 8570 
 8571 
 8572 
 8573      Time:     While system is running.
 8574 
 8575      Stream:   $security_log
 8576 
 8577      Meaning:  An  attempt  to  use  the  modification of various
 8578                segment  "  attributes  as  a  covert  channel was
 8579                detected.
 8580 
 8581 
 8582 
 8583                [page_error.alm]
 8584                AUDIT  (page_fault):   GRANTED  excessive  segment
 8585                state  changes (Moderate_cc)  for PROCESS_GROUP_ID
 8586                (AUTHORIZATION)
 8587 
 8588 
 8589 
 8590      Time:     While system is running.
 8591 
 8592      Stream:   $security_log
 8593 
 8594 
 8595 
 8596 
 8597 
 8598 AUDIT (page_fault)             149            08/21/20     MR12.7^L
 8599 
 8600 
 8601      Meaning:  An  attempt  to  use  the  modification of various
 8602                segment  "  attributes  as  a  covert  channel was
 8603                detected.
 8604 
 8605 
 8606 
 8607                [pnt_db_util_.pl1]
 8608                AUDIT  (pnt_db_util_):   GRANTED  addition  of pnt
 8609                entry  (Admin_op)  for  PERSON.PROJECT.TAG  (AUTH)
 8610                Level=1 to PNT entry USERID (no access class).
 8611 
 8612 
 8613      Stream:   $access_audit
 8614 
 8615      Time:     While system is running.
 8616 
 8617      Meaning:  The  user,  PERSON.PROJECT.TAG,  added  a  new PNT
 8618                entry for USERID
 8619 
 8620      Action:   No operator action is required.
 8621 
 8622 
 8623                [pnt_db_util_.pl1]
 8624                AUDIT  (pnt_db_util_):   GRANTED  deletion  of pnt
 8625                entry  (Admin_op)  for  PERSON.PROJECT.TAG  (AUTH)
 8626                Level=1 to PNT entry USERID (no access class).
 8627 
 8628 
 8629      Stream:   $access_audit
 8630 
 8631      Time:     While system is running.
 8632 
 8633      Meaning:  The user PERSON.PROJECT.TAG  deleted the PNT entry
 8634                for USERID.
 8635 
 8636      Action:   No operator action is required.
 8637 
 8638 
 8639                [pnt_db_util_.pl1]
 8640                AUDIT (pnt_db_util_):  GRANTED modification of pnt
 8641                entry  (Admin_op)  for  PERSON.PROJECT.TAG  (AUTH)
 8642                Level=1 to  PNT entry USERID:  CHANGES  (no access
 8643                class).
 8644 
 8645 
 8646      Stream:   $access_audit
 8647 
 8648      Time:     While system is running.
 8649 
 8650      Meaning:  The user PERSON.PROJECT.TAG modified the PNT entry
 8651                for  USERID.  CHANGES   describes in  brief format
 8652                what security relevant changes were made.  See the
 8653 
 8654 
 8655 
 8656 AUDIT (pnt_db_util_)           150            08/21/20     MR12.7^L
 8657 
 8658 
 8659                binary  information  in   the  audit  message  for
 8660                further details.
 8661 
 8662      Action:   No operator action is required.
 8663 
 8664 
 8665                [reclassify.pl1]
 8666                AUDIT (reclassify$ENTRY):  GRANTED modification of
 8667                security out-of-service ADDED_INFO
 8668 
 8669 
 8670      Stream:   $access_audit
 8671 
 8672      Time:     While system is running.
 8673 
 8674      Meaning:  An AIM error was found in respect to the specified
 8675                directory.   There was   a disagreement  in access
 8676                class between the directory  and one of it's sons,
 8677                or   there   was   an   upgraded   directory  with
 8678                non-terminal quota.
 8679 
 8680      Action:   No operator action is required.
 8681 
 8682 
 8683                [reclassify.pl1]
 8684                AUDIT      (reclassify$ENTRY):      GRANTED|DENIED
 8685                modification of fs_obj access class ADDED_INFO
 8686 
 8687 
 8688      Stream:   $access_audit
 8689 
 8690      Time:     While system is running.
 8691 
 8692      Meaning:  Indicates  whether an   attempt to  reclassify the
 8693                specified  file  system   object  was  granted  or
 8694                denied.  In the case of reclassify$node, a message
 8695                will be generated for  each entry in the directory
 8696                being reclassified.
 8697 
 8698      Action:   No operator action is required.
 8699 
 8700 
 8701                [salv_check_vtoce_.pl1]
 8702                AUDIT  (salv_check_vtoce_):  GRANTED  modification
 8703                of security out-of-service ADDED_INFO
 8704 
 8705 
 8706      Stream:   $access_audit
 8707 
 8708      Time:     While system is running.
 8709 
 8710 
 8711 
 8712 
 8713 
 8714 AUDIT (salv_check_vtoce_)      151            08/21/20     MR12.7^L
 8715 
 8716 
 8717      Meaning:  Security  out-of-service  switch  was  set because
 8718                vtoce access class did  not match the entry access
 8719                class for the specified file system entry.
 8720 
 8721      Action:   Contact the system programming staff._ssa
 8722 
 8723 
 8724                [salv_dir_checker_.pl1]
 8725                AUDIT  (salv_dir_checker_):  GRANTED  modification
 8726                of fs_obj access ADDED_INFO
 8727 
 8728 
 8729      Stream:   $access_audit
 8730 
 8731      Time:     Salvaging
 8732 
 8733      Meaning:  The salvager has truncated the ACL of a branch.
 8734 
 8735      Action:   Contact the system programming staff._ssa
 8736 
 8737 
 8738                [set_privileges.pl1]
 8739                AUDIT  (set_privileges):  GRANTED  modification of
 8740                system AIM privilege ADDED_INFO
 8741 
 8742 
 8743      Stream:   $access_audit
 8744 
 8745      Time:     While system is running.
 8746 
 8747      Meaning:  The  specified  user  made  a  privileged call for
 8748                modifying the process AIM privileges
 8749 
 8750      Action:   No operator action is required.
 8751 
 8752 
 8753                [set_sys_audit_thresholds_.pl1]
 8754                AUDIT (set_sys_audit_thresholds_):  GRANTED|DENIED
 8755                modification of system  audit flags and thresholds
 8756                ADDED_INFO
 8757 
 8758 
 8759      Stream:   $access_audit
 8760 
 8761      Time:     While system is running.
 8762 
 8763      Meaning:  Indicates that the system  wide audit enable flags
 8764                and the thresholds have been changed as indicated.
 8765 
 8766      Action:   No operator action is required.
 8767 
 8768 
 8769 
 8770 
 8771 
 8772 bce_abs_seg                    152            08/21/20     MR12.7^L
 8773 
 8774 
 8775 
 8776 
 8777                [bce_abs_seg.pl1]
 8778                bce_abs_seg:  Too many bce abs-segs.
 8779 
 8780 
 8781      Stream:   BOS Typewriter (Crashes system)
 8782 
 8783      Time:     System Intialization.
 8784 
 8785      Meaning:  More per-bce  pass abs-segs were  encountered than
 8786                fit  in the  abs-seg  array.   This is  a software
 8787                error.
 8788 
 8789 
 8790 
 8791                [bce_ioi_post.pl1]
 8792                bce_ioi_post:    Error  posting   i/o  completion.
 8793                ioi_event_channel:     CCCCCCCCCCCC   ioi_message:
 8794                MMMMMMMMMMMM
 8795 
 8796 
 8797 
 8798      Stream:   BOS Typewriter (Crashes system)
 8799 
 8800      Time:     System Intialization.
 8801 
 8802      Meaning:  No   posting   buffer   was   found   in  an  "I/O
 8803                outstanding"  state for  the above  event channel.
 8804                This indicates a logic error in the supervisor, or
 8805                CPU or memory hardware problems.
 8806 
 8807      Action:   Contact the system programming staff.
 8808 
 8809 
 8810                [bce_ioi_post.pl1]
 8811                bce_ioi_post:  System not at correct level to post
 8812                I/O completion.
 8813 
 8814 
 8815      Stream:   BOS Typewriter (Crashes system)
 8816 
 8817      Time:     System Intialization.
 8818 
 8819      Meaning:  The  flag  sys_info$service_system  indicates that
 8820                the  system  is  up  and  should  be  posting  I/O
 8821                completions via pxss$io_wakeup,  not this program.
 8822                This indicates a logic error in the supervisor, or
 8823                CPU or memory hardware problems.
 8824 
 8825      Action:   Contact the system programming staff.
 8826 
 8827 
 8828 
 8829 
 8830 bce_ioi_post                   153            08/21/20     MR12.7^L
 8831 
 8832 
 8833                [bce_ioi_post.pl1]
 8834                bce_ioi_post:      Unexpected    System     Fault.
 8835                ioi_event_channel:     CCCCCCCCCCCC   ioi_message:
 8836                MMMMMMMMMMMM
 8837 
 8838 
 8839 
 8840      Stream:   BOS Typewriter (Crashes system)
 8841 
 8842      Time:     System Intialization.
 8843 
 8844      Meaning:  This indicates a logic error in the supervisor, or
 8845                CPU or memory hardware problems.
 8846 
 8847      Action:   Contact the system programming staff.
 8848 
 8849 
 8850                [bce_save.pl1]
 8851                bce_save:  Error issuing tape connect for TAPE_DEV
 8852                (TAPE_SET).  ERR_MESSAGE
 8853 
 8854 
 8855      Stream:   BOS Typewriter (Crashes system)
 8856 
 8857      Time:     System Intialization.
 8858 
 8859      Meaning:  IOI has returned a  non-zero error, which has been
 8860                expanded  in  ERR_MESSAGE.This  indicates  a logic
 8861                error in the supervisor, or CPU or memory hardware
 8862                problems.
 8863 
 8864      Action:   Contact the system programming staff.
 8865 
 8866 
 8867                [bce_save.pl1]
 8868                bce_save:  Internal bit map for PV_NAME (TAPE_SET)
 8869                contains no in use pages.
 8870 
 8871 
 8872      Stream:   BOS Typewriter (Crashes system)
 8873 
 8874      Time:     System Intialization.
 8875 
 8876      Meaning:  The  copied/packed internal   version of  the PV's
 8877                volume  bit  map  contains   no  used  pages  (OFF
 8878                bits).This   indicates  a   logic  error   in  the
 8879                supervisor, or CPU or memory hardware problems.
 8880 
 8881      Action:   Contact the system programming staff.
 8882 
 8883 
 8884                [bce_save.pl1]
 8885 
 8886 
 8887 
 8888 bce_save                       154            08/21/20     MR12.7^L
 8889 
 8890 
 8891                bce_save:  IO complete, but NO status returned for
 8892                TAPE_SET.
 8893 
 8894 
 8895      Stream:   BOS Typewriter (Crashes system)
 8896 
 8897      Time:     System Intialization.
 8898 
 8899      Meaning:  An  I/O   has  been  posted,  but   there  was  no
 8900                indication of status being returned.This indicates
 8901                a logic error in the  supervisor, or CPU or memory
 8902                hardware problems.
 8903 
 8904      Action:   Contact the system programming staff.
 8905 
 8906 
 8907                [bce_save.pl1]
 8908                bce_save:  Out of disk buffers for TAPE_SET.
 8909 
 8910 
 8911      Stream:   BOS Typewriter (Crashes system)
 8912 
 8913      Time:     System Intialization.
 8914 
 8915      Meaning:  This indicates a logic error in the supervisor, or
 8916                CPU or memory hardware problems.
 8917 
 8918      Action:   Contact the system programming staff.
 8919 
 8920 
 8921                [bce_save.pl1]
 8922                bce_save:  Out of tape buffers for TAPE_SET.
 8923 
 8924 
 8925      Stream:   BOS Typewriter (Crashes system)
 8926 
 8927      Time:     System Intialization.
 8928 
 8929      Meaning:  This indicates a logic error in the supervisor, or
 8930                CPU or memory hardware problems.
 8931 
 8932      Action:   Contact the system programming staff.
 8933 
 8934 
 8935                [bce_save_util_.pl1]
 8936                bce_save_util_:  Out of disk buffers for TAPE_SET.
 8937 
 8938 
 8939      Stream:   BOS Typewriter (Crashes system)
 8940 
 8941      Time:     System Intialization.
 8942 
 8943 
 8944 
 8945 
 8946 bce_save_util_                 155            08/21/20     MR12.7^L
 8947 
 8948 
 8949      Meaning:  This indicates a logic error in the supervisor, or
 8950                CPU or memory hardware problems.
 8951 
 8952      Action:   Contact the system programming staff.
 8953 
 8954 
 8955                [wired_shutdown.pl1]
 8956                begin emergency shutdown part 1
 8957 
 8958 
 8959      Stream:   BOS Typewriter.
 8960 
 8961      Time:     Emergency shutdown
 8962 
 8963      Meaning:  The system emergency shutdown environment has been
 8964                successfully established.  An attempt will be made
 8965                to write  out all of  memory and flush  the paging
 8966                device.
 8967 
 8968      Action:   No operator action is required.
 8969 
 8970 
 8971                [boot_tape_io.pl1]
 8972                boot_tape_io:  Code CODE from absadr.
 8973 
 8974 
 8975      Stream:   BOS Typewriter (Crashes system)
 8976 
 8977      Time:     System Intialization.
 8978 
 8979      Meaning:  boot_tape_io was unable to find the address of its
 8980                buffer.   This  indicates  a  logic  error  in the
 8981                supervisor, or CPU or memory hardware problems.
 8982 
 8983      Action:   $boot_tape
 8984 
 8985 
 8986                [boot_tape_io.pl1]
 8987                boot_tape_io:  Code CODE from io_manager$assign
 8988 
 8989 
 8990      Stream:   BOS Typewriter (Crashes system)
 8991 
 8992      Time:     System Intialization.
 8993 
 8994      Meaning:  The bootload tape reading package could not assign
 8995                the bootload tape drive to itself.  This indicates
 8996                a logic error in the  supervisor, or CPU or memory
 8997                hardware problems.
 8998 
 8999      Action:   $boot_tape
 9000 
 9001 
 9002 
 9003 
 9004 boot_tape_io                   156            08/21/20     MR12.7^L
 9005 
 9006 
 9007 
 9008 
 9009                [boot_tape_io.pl1]
 9010                boot_tape_io:  Unable to allocate buffer.
 9011 
 9012 
 9013      Stream:   BOS Typewriter (Crashes system)
 9014 
 9015      Time:     System Intialization.
 9016 
 9017      Meaning:  The  bootload  tape   reading  package  could  not
 9018                allocate  a wired-down  buffer into  which to read
 9019                the bootload  tape.  This indicates a  logic error
 9020                in  the  supervisor,  or  CPU  or  memory hardware
 9021                problems.
 9022 
 9023      Action:   $boot_tape
 9024 
 9025 
 9026                [bootload_error.alm]
 9027                bootload_0:  An unpaged  page table overflowed for
 9028                seg N.
 9029 
 9030 
 9031      Stream:   BOS Typewriter (Crashes system)
 9032 
 9033      Time:     System Intialization.
 9034 
 9035      Meaning:  The  size of the  page table needed  for "unpaged"
 9036                segment  N exceeded  the area  left for  such page
 9037                tables.
 9038 
 9039      Action:   The  system  tape  was  generated  improperly; use
 9040                another copy of the system tape.
 9041 
 9042 
 9043 
 9044                [bootload_error.alm]
 9045                bootload_0:  Bad MST format.
 9046 
 9047 
 9048      Stream:   BOS Typewriter (Crashes system)
 9049 
 9050      Time:     System Intialization.
 9051 
 9052      Meaning:  The records on the MST tape were out of sequence.
 9053 
 9054      Action:   Try another tape.
 9055 
 9056 
 9057                [bootload_error.alm]
 9058                bootload_0:  Booted tape MPC.
 9059 
 9060 
 9061 
 9062 bootload_0                     157            08/21/20     MR12.7^L
 9063 
 9064 
 9065      Stream:   BOS Typewriter.
 9066 
 9067      Time:     System Intialization.
 9068 
 9069      Meaning:  The system succeeded in  booting the bootload tape
 9070                mpc.
 9071 
 9072 
 9073                [bootload_error.alm]
 9074                bootload_0:   Booting FWNAME   IOM CHAN  with FWID
 9075                FWREV firmware.
 9076 
 9077 
 9078      Stream:   BOS Typewriter.
 9079 
 9080      Time:     System Intialization.
 9081 
 9082      Meaning:  The  system is  about  to  boot firmware  into the
 9083                bootload tape mpc.
 9084 
 9085 
 9086 
 9087                [bootload_error.alm]
 9088                bootload_0:    Booting   system   SYSID  generated
 9089                CREATION_TIME
 9090 
 9091 
 9092      Stream:   BOS Typewriter.
 9093 
 9094      Time:     System Intialization.
 9095 
 9096      Meaning:  This  is  the  first  message  printed by Multics,
 9097                announcing the sysid and creation date/time of the
 9098                system tape.
 9099 
 9100 
 9101 
 9102                [bootload_error.alm]
 9103                bootload_0:  Console status WORD1 WORD2
 9104 
 9105 
 9106      Stream:   BOS Typewriter (Crashes system)
 9107 
 9108      Time:     System Intialization.
 9109 
 9110      Meaning:  An  I/O  error  was  encountered  on  the console.
 9111                WORD1 and  WORD2 are the  two words of  the status
 9112                returned.
 9113 
 9114      Action:   Run T&D on the console.
 9115 
 9116 
 9117 
 9118 
 9119 
 9120 bootload_0                     158            08/21/20     MR12.7^L
 9121 
 9122 
 9123 
 9124 
 9125                [bootload_error.alm]
 9126                bootload_0:  Enter boot tape MPC model:
 9127 
 9128 
 9129      Stream:   BOS Typewriter.
 9130 
 9131      Time:     System Intialization.
 9132 
 9133      Meaning:  This query  requests the operator to  identify the
 9134                bootload tape mpc so  that firmware may be loaded.
 9135                Refer to the MOH for details.
 9136 
 9137 
 9138 
 9139                [bootload_error.alm]
 9140                bootload_0:   Enter tape  drive number  for memory
 9141                dump:
 9142 
 9143 
 9144      Stream:   BOS Typewriter.
 9145 
 9146      Time:     BOS Typewriter (Crashes system)
 9147 
 9148      Meaning:  An initialization failure occured when the toehold
 9149                was  not  active.   The  system  is requesting the
 9150                number of a tape drive on the bootload tape mpc on
 9151                which to write a dump of memory.
 9152 
 9153 
 9154 
 9155                [bootload_error.alm]
 9156                bootload_0:   Error  status  WORD1  WORD2  booting
 9157                FWTYPE firmware.
 9158 
 9159 
 9160      Stream:   BOS Typewriter.
 9161 
 9162      Time:     System Intialization.
 9163 
 9164      Meaning:  An error occured when  attempting to boot firmware
 9165                into the  bootload tape mpc.  WORD1  and WORD2 are
 9166                the status returned.
 9167 
 9168      Action:   Try another firmware identifier.
 9169 
 9170 
 9171                [bootload_error.alm]
 9172                bootload_0:  Excessive tape  errors:  status WORD1
 9173                WORD2.
 9174 
 9175 
 9176 
 9177 
 9178 bootload_0                     159            08/21/20     MR12.7^L
 9179 
 9180 
 9181      Stream:   BOS Typewriter.
 9182 
 9183      Time:     BOS Typewriter (Crashes system)
 9184 
 9185      Meaning:  An excessive  number of write errors  occured when
 9186                trying to  write an early dump tape.   The dump to
 9187                this tape will be aborted.
 9188 
 9189      Action:   Try another tape.
 9190 
 9191 
 9192                [bootload_error.alm]
 9193                bootload_0:  External symbol not found:  SEG$ENTRY
 9194 
 9195 
 9196      Stream:   BOS Typewriter.
 9197 
 9198      Time:     System Intialization.
 9199 
 9200      Meaning:  The  entrypoint  ENTRY  was  not  found within the
 9201                existant   segment  SEG   during  pre-linking   of
 9202                collection 1.   This may indicate that  the system
 9203                tape was generated improperly.
 9204 
 9205 
 9206 
 9207                [bootload_error.alm]
 9208                bootload_0:  Improper text/link/def sequence.
 9209 
 9210 
 9211      Stream:   BOS Typewriter (Crashes system)
 9212 
 9213      Time:     System Intialization.
 9214 
 9215      Meaning:  Text,  linkage,  or  definitions  appeared  out of
 9216                proper sequence " on the Multics system tape.
 9217 
 9218      Action:   The  system  tape  was  generated  improperly; use
 9219                another copy " of the system tape.
 9220 
 9221 
 9222 
 9223                [bootload_error.alm]
 9224                bootload_0:  Out of main memory.
 9225 
 9226 
 9227      Stream:   BOS Typewriter (Crashes system)
 9228 
 9229      Time:     System Intialization.
 9230 
 9231      Meaning:  Not enough  main memory is configured  in order to
 9232                load " collection 1.
 9233 
 9234 
 9235 
 9236 bootload_0                     160            08/21/20     MR12.7^L
 9237 
 9238 
 9239      Action:   Configure more main memory and boot again.
 9240 
 9241 
 9242                [bootload_error.alm]
 9243                bootload_0:  Shutdown
 9244 
 9245 
 9246      Stream:   BOS Typewriter (Crashes system)
 9247 
 9248      Time:     System Intialization.
 9249 
 9250      Meaning:  The  operator answered  "shut" when  asked for the
 9251                bootload tape mpc information.
 9252 
 9253      Action:   $reboot
 9254 
 9255 
 9256                [bootload_error.alm]
 9257                bootload_0:  Tape read error:  WORD1 WORD2
 9258 
 9259 
 9260      Stream:   BOS Typewriter (Crashes system)
 9261 
 9262      Time:     System Intialization.
 9263 
 9264      Meaning:  An I/O error was  encountered when reading the MST
 9265                tape.  WORD1  and WORD2 are  the two words  of the
 9266                status returned.
 9267 
 9268      Action:   $reboot
 9269 
 9270 
 9271                [bootload_error.alm]
 9272                bootload_0:  Too many supervisor segments.
 9273 
 9274 
 9275      Stream:   BOS Typewriter (Crashes system)
 9276 
 9277      Time:     System Intialization.
 9278 
 9279      Meaning:  More than 256 supervisor segments were declared on
 9280                the MST.
 9281 
 9282      Action:   The  system  tape  was  generated  improperly; use
 9283                another copy of the system tape.
 9284 
 9285 
 9286 
 9287                [bootload_error.alm]
 9288                bootload_0:   Unexpected  control   word  on  tape
 9289                CONTROL_WORD.
 9290 
 9291 
 9292 
 9293 
 9294 bootload_0                     161            08/21/20     MR12.7^L
 9295 
 9296 
 9297      Stream:   BOS Typewriter (Crashes system)
 9298 
 9299      Time:     System Intialization.
 9300 
 9301      Meaning:  An unexpected Multics system tape control word was
 9302                encountered.
 9303 
 9304      Action:   The  system  tape  was  generated  improperly; use
 9305                another copy of the system tape.
 9306 
 9307 
 9308 
 9309                [bootload_error.alm]
 9310                bootload_0:  Unknown tape MPC model NAME.
 9311 
 9312 
 9313      Stream:   BOS Typewriter.
 9314 
 9315      Time:     System Intialization.
 9316 
 9317      Meaning:  The   operator  entered   an  unrecognizable   mpc
 9318                identifier.
 9319 
 9320      Action:   Try another mpc identifier.
 9321 
 9322 
 9323                [bootload_disk_post.pl1]
 9324                bootload_disk_post:  Attempt to post non-requested
 9325                i/o completion.
 9326 
 9327 
 9328      Stream:   BOS Typewriter (Crashes system)
 9329 
 9330      Time:     System Intialization.
 9331 
 9332      Meaning:  disk_control  detected  an   i/o  completion  that
 9333                Bootload Multics does not believe it requested.
 9334 
 9335      Action:   Reboot.
 9336 
 9337 
 9338                [bootload_disk_post.pl1]
 9339                bootload_disk_post:  Attempt to post non-requested
 9340                i/o completion.
 9341 
 9342 
 9343      Stream:   BOS Typewriter (Crashes system)
 9344 
 9345      Time:     System Intialization.
 9346 
 9347      Meaning:  disk_control  detected  an   i/o  completion  that
 9348                Bootload Multics does not believe it requested.
 9349 
 9350 
 9351 
 9352 bootload_disk_post             162            08/21/20     MR12.7^L
 9353 
 9354 
 9355      Action:   Reboot.
 9356 
 9357 
 9358                [boundfault.pl1]
 9359                boundfault:  activating into father XXX|YYY
 9360 
 9361 
 9362      Stream:   BOS Typewriter (Crashes system)
 9363 
 9364      Time:     While system is running.
 9365 
 9366      Meaning:  While activating  a segment, the  parent directory
 9367                for   the   segment   became   deactivated.   This
 9368                indicates a logic error  in the supervisor, or CPU
 9369                or memory hardware problems.
 9370 
 9371      Action:   Follow normal recovery procedures.
 9372 
 9373 
 9374                [boundfault.pl1]
 9375                boundfault:  on the root
 9376 
 9377 
 9378      Stream:   BOS Typewriter (Terminates user process)
 9379 
 9380      Time:     While system is running.
 9381 
 9382      Meaning:  A  boundfault  on  the  root  directory  has  been
 9383                encountered.  This indicates a  logic error in the
 9384                supervisor, or CPU or memory hardware problems.
 9385 
 9386      Action:   Contact the system programming staff.
 9387 
 9388 
 9389                [cache_tester.pl1]
 9390                cache_tester:  cache parity  error detected on CPU
 9391                <TAG>  bit  failures  at  level  W,  column XXX in
 9392                cache:    YYYYYYYYYYYYYYYYYYYYYYYY    in   memory:
 9393                ZZZZZZZZZZZZZZZZZZZZZZZZ.
 9394 
 9395 
 9396 
 9397      Stream:   BOS Typewriter.
 9398 
 9399      Time:     While system is running.
 9400 
 9401      Meaning:  This message is the result of a multiple bit cache
 9402                failure   detected   and   cache   data   and  its
 9403                corresponding memory data captured by the fim.  It
 9404                should be noted that when  a cache parity error is
 9405                detected  by the  fim, there  is a  window of time
 9406                before the address in cache  and in main store can
 9407                be determined.   Although the cache error  data is
 9408 
 9409 
 9410 cache_tester                   163            08/21/20     MR12.7^L
 9411 
 9412 
 9413                frozen  (cache is  turned off  unconditionaly when
 9414                the  parity  retry  of  the  fim  is  called), the
 9415                corresponding  address in   main store  might have
 9416                been changed  through paging migration  from other
 9417                processors.   This  message  then  might  not be a
 9418                multiple  error  but  rather  the  result  of this
 9419                window  condition.  If  this message  was the only
 9420                diagnostic displayed (i.e.   the static test found
 9421                no errors), the cache will be turned back on.  The
 9422                values  of W,  XXX,  YYY...Y,  and ZZZ...Z  are as
 9423                explained above.
 9424 
 9425      Action:   Contact Field Engineering
 9426 
 9427 
 9428                [cache_tester.pl1]
 9429                cache_tester:  cache parity  error detected on CPU
 9430                <TAG> at:  board XXXX, chip YY.
 9431 
 9432 
 9433 
 9434      Stream:   BOS Typewriter.
 9435 
 9436      Time:     While system is running.
 9437 
 9438      Meaning:  This message  is the result of a  single bit cache
 9439                failure   detected   and   cache   data   and  its
 9440                corresponding  memory data   captured by  the fim.
 9441                This message  will be displayed if  the diagnostic
 9442                error data  from the fim is valid.   The board and
 9443                chip callout are as explained above.
 9444 
 9445      Action:   Contact field Engineering.
 9446 
 9447 
 9448                [cache_tester.pl1]
 9449                cache_tester:  cache parity  error detected on CPU
 9450                <TAG>  cache data  is  equal  to the  memory data.
 9451                parity generation problem for level <L>.
 9452 
 9453 
 9454 
 9455      Stream:   BOS Typewriter.
 9456 
 9457      Time:     While system is running.
 9458 
 9459      Meaning:  This  message is  the  result  of a  cache failure
 9460                detected  and  cache  data  and  its corresponding
 9461                memory  data captured  by the  fim.  This  message
 9462                will  be displayed  if the  diagnostic error  data
 9463                from the fim is valid.
 9464 
 9465      Action:   Contact field Engineering.
 9466 
 9467 
 9468 cache_tester                   164            08/21/20     MR12.7^L
 9469 
 9470 
 9471 
 9472 
 9473                [cache_tester.pl1]
 9474                cache_tester:  Entire  cache memory for  CPU <TAG>
 9475                has been disabled.
 9476 
 9477 
 9478      Stream:   BOS Typewriter (sounds beeper)
 9479 
 9480      Time:     While system is running.
 9481 
 9482      Meaning:  The  static test  of  cache  memory for  CPU <TAG>
 9483                detected repeatable errors in both halfs of cache.
 9484                or one half of  cache had previously been disabled
 9485                and  the static  test of  the other  half detected
 9486                repeatable errors.
 9487 
 9488      Action:   Contact field Engineering
 9489 
 9490 
 9491                [cache_tester.pl1]
 9492                cache_tester:  LLUU cache  memory (csh<n>) for CPU
 9493                <TAG> has been turned off OTHER was AA and has not
 9494                been changed.
 9495 
 9496 
 9497 
 9498      Stream:   BOS Typewriter (sounds beeper)
 9499 
 9500      Time:     While system is running.
 9501 
 9502      Meaning:  Either the lower  half (LLUU = Lower, <n>  = 1) or
 9503                the upper  half (LLUU =  Upper, <n> =  2) of cache
 9504                memory for  CPU <TAG> has  been turned off  as the
 9505                result  of   the  static  cache  test   finding  a
 9506                repeatable  cache failure.    The OTHER  (Upper or
 9507                Lower) was in state AA.  If AA is off this half of
 9508                cache was  not tested.  If  AA is on  this half of
 9509                cache had no errors.
 9510 
 9511      Action:   Contact Field Engineering
 9512 
 9513 
 9514                [cache_tester.pl1]
 9515                cache_tester:  No errors found in cache memory for
 9516                CPU <TAG>, cache will remain on.
 9517 
 9518 
 9519      Stream:   BOS Typewriter.
 9520 
 9521      Time:     While system is running.
 9522 
 9523 
 9524 
 9525 
 9526 cache_tester                   165            08/21/20     MR12.7^L
 9527 
 9528 
 9529      Meaning:  The  static test  of  cache  memory for  CPU <TAG>
 9530                found no errors and no cache error information was
 9531                captured by the fim.
 9532 
 9533      Action:   cache is turned back on
 9534 
 9535 
 9536                [cache_tester.pl1]
 9537                cache_tester:    repeatable  cache   parity  error
 9538                detected on  CPU <TAG> cache data is  equal to the
 9539                memory data.  parity  generation problem for level
 9540                <L>.
 9541 
 9542 
 9543 
 9544      Stream:   BOS Typewriter.
 9545 
 9546      Time:     While system is running.
 9547 
 9548      Meaning:  The  static test  of  cache  memory for  CPU <TAG>
 9549                detected  a cache  failure, but  the data  and its
 9550                corresponding memory data are equal.
 9551 
 9552      Action:   Contact field Engineering.
 9553 
 9554 
 9555                [cache_tester.pl1]
 9556                cache_tester:   repeatable  cache  parity error(s)
 9557                detected  on CPU  <TAG> bit  failures at  level W,
 9558                column XXX in  cache:  YYYYYYYYYYYYYYYYYYYYYYYY in
 9559                memory:  ZZZZZZZZZZZZZZZZZZZZZZZZ.
 9560 
 9561 
 9562 
 9563      Stream:   BOS Typewriter.
 9564 
 9565      Time:     While system is running.
 9566 
 9567      Meaning:  The  static test  of  cache  memory for  CPU <TAG>
 9568                indicated  a   multiple  bit  error   between  the
 9569                contents  of cache and  the contents of  the wired
 9570                test buffer.  The multiple  bit failure is further
 9571                broken down to the failing cache level (W) (0 - 3)
 9572                and  column  (XXX)  address.   The  data read from
 9573                cache (YYY...Y) and the expected data (ZZZ...Z) is
 9574                displayed as an aid for the field engineer.  Since
 9575                the  failure happened  during the  static test  of
 9576                cache,  it is  assumed to  be a  solid failure and
 9577                that  segment of  cache memory  (csh1 or  csh2) is
 9578                turned  off.   There  could  be  up  to 3 multiple
 9579                messages or some combination of multiple bit error
 9580                messages  and  board   and  chip  callouts,  since
 9581 
 9582 
 9583 
 9584 cache_tester                   166            08/21/20     MR12.7^L
 9585 
 9586 
 9587                diagnostic  data for the  first 3 cache  errors is
 9588                captured.
 9589 
 9590      Action:   Contact Field Engineering personnel.
 9591 
 9592 
 9593                [cache_tester.pl1]
 9594                cache_tester:   repeatable  cache  parity error(s)
 9595                detected on CPU <TAG> at:  board XXXX, chip YY.
 9596 
 9597 
 9598 
 9599      Stream:   BOS Typewriter.
 9600 
 9601      Time:     While system is running.
 9602 
 9603      Meaning:  The  static test  of  cache  memory for  CPU <TAG>
 9604                indicated a single bit  error between the contents
 9605                of  cache  and  the  contents  of  the  wired test
 9606                buffer.  The single bit  failure is further broken
 9607                down  to  the  failing  wire  wrapped board (board
 9608                XXXX) and  integrated circuit chip (chip  YY) that
 9609                failed.  Since it happened  during the static test
 9610                of cache, it is assumed  to be a solid failure and
 9611                that  segment of  cache memory  (csh1 or  csh2) is
 9612                turned off.  There could be up to 3 board and chip
 9613                callouts  since diagnostic  data for  the first  3
 9614                cache errors is  captured.  These additional board
 9615                and  chip callouts will  only be displayed  if the
 9616                single  bit   failure  was  a  different   bit  or
 9617                different  cache  level  than  the  board and chip
 9618                diagnostic already displayed.
 9619 
 9620      Action:   Contact Field Engineering personnel.
 9621 
 9622 
 9623                [cache_tester.pl1]
 9624                cache_tester:  Unable to allocate wired buffer.
 9625 
 9626 
 9627      Stream:   BOS Typewriter.
 9628 
 9629      Time:     While system is running.
 9630 
 9631      Meaning:  Attempted to allocate  wired contiguous buffer for
 9632                cache testing and pc_contig  could not find enough
 9633                pages available.
 9634 
 9635      Action:   If cache error information was captured in the fim
 9636                this  information is  displayed.  Cache  memory is
 9637                turned back on.
 9638 
 9639 
 9640 
 9641 
 9642 cache_tester                   167            08/21/20     MR12.7^L
 9643 
 9644 
 9645 
 9646 
 9647                [cache_tester.pl1]
 9648                cache_tester:  Unable to run  on CPU <TAG> to EEDD
 9649                cache ERRORMESSAGE.
 9650 
 9651 
 9652      Stream:   BOS Typewriter (sounds beeper)
 9653 
 9654      Time:     While system is running.
 9655 
 9656      Meaning:  The attempt  to run on CPU <TAG>  to either enable
 9657                (EEDD - enable) or  disable (EEDD = disable) cache
 9658                memory failed.
 9659 
 9660      Action:   CPU <TAG>  should be taken offline  if the attempt
 9661                was to disable cache memory.
 9662 
 9663 
 9664 
 9665                [cache_tester.pl1]
 9666                cache_tester:  Unable to set CPU required to <TAG>
 9667                cache is off ERRORMESSAGE.
 9668 
 9669 
 9670      Stream:   BOS Typewriter.
 9671 
 9672      Time:     While system is running.
 9673 
 9674      Meaning:  Attempted  to run on  CPU <TAG> for  cache testing
 9675                and could not set CPU required to that CPU.
 9676 
 9677      Action:   Cache memory is turned back on.
 9678 
 9679 
 9680                [call_bce.pl1]
 9681                call_bce:  bce called from Multics.
 9682 
 9683 
 9684      Stream:   BOS Typewriter.
 9685 
 9686      Time:     While system is running.
 9687 
 9688      Meaning:  An outer ring  program has called hphcs_$call_bce.
 9689                This is usually done after printing an explanatory
 9690                message.   The  system  will  resume  operation if
 9691                continue is typed.
 9692 
 9693      Action:   Follow normal recovery procedures.
 9694 
 9695 
 9696                [disk_rebuild_caller.pl1]
 9697 
 9698 
 9699 
 9700 Cannot                         168            08/21/20     MR12.7^L
 9701 
 9702 
 9703                Cannot   shrink  VTOC   from  XX   to  YY  VTOCEs.
 9704                Respecify parameters.
 9705 
 9706 
 9707      Stream:   Initializer process output.
 9708 
 9709      Time:     In response to an operator command.
 9710 
 9711      Meaning:  An attempt has been made to shrink the VTOC, which
 9712                is illegal.
 9713 
 9714      Action:   Respecify the parameters.
 9715 
 9716 
 9717                [mc_tty_.pl1]
 9718                Channel    CHANNEL_NAME   attached    by   Message
 9719                Coordinator.
 9720 
 9721 
 9722      Stream:   Initializer terminal.
 9723 
 9724      Time:     While system is running.
 9725 
 9726      Meaning:  The  terminal  has  been  attached  by the message
 9727                coordinator  in response  to an  accept or substty
 9728                command.
 9729 
 9730      Action:   Proceed to use the terminal.
 9731 
 9732 
 9733                [channel_manager.pl1]
 9734                channel_manager:     Cleanup   while    processing
 9735                interrupt for devx N.
 9736 
 9737 
 9738      Stream:   BOS Typewriter (Crashes system)
 9739 
 9740      Time:     While system is running.
 9741 
 9742      Meaning:  The   cleanup   condition   was   signalled  while
 9743                processing an interrupt for  the channel with devx
 9744                N.
 9745 
 9746      Action:   Contact the system programming staff.
 9747 
 9748 
 9749                [channel_manager.pl1]
 9750                channel_manager:  Error while processing interrupt
 9751                for devx N.  REASON
 9752 
 9753 
 9754      Stream:   BOS Typewriter (Crashes system)
 9755 
 9756 
 9757 
 9758 channel_manager                169            08/21/20     MR12.7^L
 9759 
 9760 
 9761      Time:     While system is running.
 9762 
 9763      Meaning:  An  error occurred  while processing  an interrupt
 9764                for the channel with devx N.  The specific kind of
 9765                error is explained by REASON.
 9766 
 9767 
 9768 
 9769                [dn355_boot_interrupt.pl1]
 9770                checksum error in core image for FNP X
 9771 
 9772 
 9773      Stream:   BOS Typewriter.
 9774 
 9775      Time:     When bootloading an FNP
 9776 
 9777      Meaning:  The core image received for loading in the FNP had
 9778                a checksum error.
 9779 
 9780      Action:   Try to  load the FNP again.  If  the error recurs,
 9781                either  the DIA hardware  is failing, or  the core
 9782                image in the Multics hierarchy is damaged.  In the
 9783                latter case, the core image must be rebound.
 9784 
 9785 
 9786 
 9787                [system_startup_.pl1]
 9788                Command:
 9789 
 9790 
 9791      Stream:   BOS Typewriter.
 9792 
 9793      Time:     System Intialization.
 9794 
 9795      Meaning:  The Initializer types this  message whenever it is
 9796                waiting for a ring 1 command.
 9797 
 9798      Action:   Type the  desired command.  The normal  command to
 9799                type when bringing the system up is startup.
 9800 
 9801 
 9802 
 9803                [config_.pl1]
 9804                config_$find_table:  TBLS card  specifies no value
 9805                for NAME.
 9806 
 9807 
 9808      Stream:   BOS Typewriter (sounds beeper)
 9809 
 9810      Meaning:  The config deck does not specify a value for NAME.
 9811 
 9812      Action:   One  should  be  added.   Message:  config_$ENTRY:
 9813                the config deck is full.
 9814 
 9815 
 9816 config_$find_table             170            08/21/20     MR12.7^L
 9817 
 9818 
 9819      Stream:   BOS Typewriter (Crashes system)
 9820 
 9821      Meaning:  No   space  remained   in  the   config  deck  for
 9822                additional cards.
 9823 
 9824      Action:   If  this recurs,  try another  boot tape.   Remove
 9825                unneccessary config cards.
 9826 
 9827 
 9828 
 9829                [dn355_boot_interrupt.pl1]
 9830                configuration   error   reported   by  bootloading
 9831                program for FNP X
 9832 
 9833 
 9834      Stream:   BOS Typewriter.
 9835 
 9836      Time:     When bootloading an FNP
 9837 
 9838      Meaning:  The   FNP  bootload    program,  gicb,   found  an
 9839                inconsistency in the FNP configuration.
 9840 
 9841      Action:   Contact the system programming staff.
 9842 
 9843 
 9844                [dn355_boot_interrupt.pl1]
 9845                configuration error reported by FNP X:  DETAILS
 9846 
 9847 
 9848      Stream:   BOS Typewriter.
 9849 
 9850      Time:     When bootloading an FNP
 9851 
 9852      Meaning:  The FNP  initialization program detected  an error
 9853                or   inconsistency  in   the  FNP   configuration.
 9854                DETAILS  is  a  more  specific  description of the
 9855                error.
 9856 
 9857      Action:   If possible, correct the error, either by updating
 9858                the  CDT to  reflect the  actual configuration, or
 9859                recabling  the  FNP.   If   the  error  cannot  be
 9860                corrected or is not understood, inform the systems
 9861                programming staff.
 9862 
 9863 
 9864 
 9865                [configure_test_cpu.pl1]
 9866                configure_test_cpu:   Unable  to   run  on  CPU  X
 9867                ERRORMESSAGE
 9868 
 9869 
 9870      Stream:   BOS Typewriter (Crashes system)
 9871 
 9872 
 9873 
 9874 configure_test_cpu             171            08/21/20     MR12.7^L
 9875 
 9876 
 9877      Time:     When ISOLTS is terminating
 9878 
 9879      Meaning:  The system is attempting to restore the ISOLTS CPU
 9880                to  service.    In  attempting  to   reassign  its
 9881                interrupt mask, it was unable  to run on that CPU.
 9882                This indicates hardware or software malfunction.
 9883 
 9884      Action:   Follow normal recovery procedures.
 9885 
 9886 
 9887                [disk_table_.pl1]
 9888                continuing demount of lv LVNAME
 9889 
 9890 
 9891      Stream:   Initializer process output.
 9892 
 9893      Time:     While  system is  running.  The  operator issued a
 9894                dlv  command  for  a  logical  volume  for which a
 9895                previous dlv command failed.
 9896 
 9897      Action:   No operator action is required.
 9898 
 9899 
 9900                [copy_fdump.pl1]
 9901                copy_fdump:   Copied   fdump  image  of   erf  NNN
 9902                (MM/DD/YY HHMM.M) for USERNAME
 9903 
 9904 
 9905      Stream:   BOS Typewriter.
 9906 
 9907      Time:     While system is running.
 9908 
 9909      Meaning:  The user  identified by USERNAME  has successfully
 9910                copied the  FDUMP image for the  specified ERF out
 9911                of  the DUMP  partition.  The  time the  FDUMP was
 9912                taken  is  also  included  in  the  message.  This
 9913                message  is informational   only, and  is intended
 9914                only  as an  aid  in  tracking system  progress by
 9915                perusing the syserr log.
 9916 
 9917      Action:   No operator action is required.
 9918 
 9919 
 9920                [copy_fdump.pl1]
 9921                copy_fdump:  unexpected NAME signal.
 9922 
 9923 
 9924      Stream:   BOS Typewriter.
 9925 
 9926      Time:     While system is running.
 9927 
 9928      Meaning:  An  attempt  to  copy   the  dump  from  the  DUMP
 9929                partition with copy_fdump resulted in an unclaimed
 9930 
 9931 
 9932 copy_fdump                     172            08/21/20     MR12.7^L
 9933 
 9934 
 9935                signal.   This may  be due  to damage  to the DUMP
 9936                partition contents, a malfunction  of the BCE dump
 9937                command,   a  supervisor    error,  or   a  simple
 9938                difficulty  like running  out of  space in >dumps.
 9939                The system  continues operation.  The  copied dump
 9940                may be only partly valid.
 9941 
 9942      Action:   Contact the system programming staff.
 9943 
 9944 
 9945                [correct_qused.pl1]
 9946                correct_qused:  hash error
 9947 
 9948 
 9949      Stream:   BOS Typewriter (Crashes system)
 9950 
 9951      Time:     While system is running.
 9952 
 9953      Meaning:  Multiple  entries  within  a  directory undergoing
 9954                quota correction have the same UID.
 9955 
 9956 
 9957 
 9958                [cpg_.pl1]
 9959                cpg_:   Error:   CONDITION  attempting  to  create
 9960                process for NAME.PROJ
 9961 
 9962 
 9963      Stream:   as (severity1)
 9964 
 9965      Time:     While system is running.
 9966 
 9967      Meaning:  A supervisor error prevented creation of a process
 9968                for the user NAME.PROJ.  An Answering Service dump
 9969                was  performed  and  the  user  was  logged out if
 9970                possible.
 9971 
 9972      Action:   Note  for  system   programmer  action.   If  this
 9973                message is printed at  every login, it is probably
 9974                wise  to  shut  the  system  down  and  perform  a
 9975                bootload operation.
 9976 
 9977 
 9978 
 9979                [cpg_.pl1]
 9980                cpg_:   ERROR_MESSAGE.  Assigning pdir  volume for
 9981                USER
 9982 
 9983 
 9984      Stream:   as (severity2)
 9985 
 9986      Time:     While system is running.
 9987 
 9988 
 9989 
 9990 cpg_                           173            08/21/20     MR12.7^L
 9991 
 9992 
 9993      Meaning:  The system  was unable to assign  a logical volume
 9994                on which to place the process directory of a user.
 9995                The user might not be able to log in
 9996 
 9997      Action:   Contact the system programming staff.
 9998 
 9999 
10000                [cpg_.pl1]
10001                cpg_:  ERROR_MESSAGE.  Cannot truncate pit_temp_
10002 
10003 
10004      Stream:   as (severity2)
10005 
10006      Time:     While system is running.
10007 
10008      Meaning:  The  system  was  unable  to  clear  its temporary
10009                segment  while attempting to  log in a  user.  The
10010                user will be unable to log in.
10011 
10012      Action:   Contact the system programming staff.
10013 
10014 
10015                [tc_init.pl1]
10016                CPU CPUTAG:   Model #:  MODEL; Serial  #:  SERIAL;
10017                Ship date:  YY/MM/DD.
10018 
10019 
10020      Stream:   Logged in SYSERR log.
10021 
10022      Time:     When  the bootload  CPU is  a DPS8,  whose tag  is
10023                CPUTAG is "added" to the system.
10024 
10025      Meaning:  The MODEL, SERIAL and YY/MM/DD information is read
10026                from the DPS8 cpu's ID PROM.  It is intended to be
10027                used  as  historical  information  for  identifing
10028                CPUs,  regardless  of  what  their  current tag is
10029                assigned as.
10030 
10031      Action:   No operator action is required.
10032 
10033 
10034                [tc_init.pl1]
10035                CPU CPUTAG:   Model #:  MODEL; Serial  #:  SERIAL;
10036                Ship date:  YY/MM/DD.
10037 
10038 
10039      Stream:   Logged in SYSERR log.
10040 
10041      Time:     When  the bootload  CPU is  a DPS8,  whose tag  is
10042                CPUTAG is "added" to the system.
10043 
10044      Meaning:  The MODEL, SERIAL and YY/MM/DD information is read
10045                from the DPS8 cpu's ID PROM.  It is intended to be
10046 
10047 
10048 CPU CPUTAG                     174            08/21/20     MR12.7^L
10049 
10050 
10051                used  as  historical  information  for  identifing
10052                CPUs,  regardless  of  what  their  current tag is
10053                assigned as.
10054 
10055      Action:   No operator action is required.
10056 
10057 
10058                [obs_reconfigure.pl1]
10059                CPU X is now running.
10060 
10061 
10062      Stream:   Initializer process output.
10063 
10064      Time:     In response to an operator command.
10065 
10066      Meaning:  This  is the  response  to  a successful  addcpu X
10067                command.
10068 
10069      Action:   No operator action is required.
10070 
10071 
10072                [create_homedir_.pl1]
10073                create_homedir_:  Bad syntax in pathname.  DIRNAME
10074                NAME.PROJ
10075 
10076 
10077      Stream:   as (severity0).
10078 
10079      Time:     While system is running.
10080 
10081      Meaning:  Typically   caused  by  a   homedir  specification
10082                starting  with other  than >user_dir_dir  or >udd.
10083                It may  also occur while attempting  to create the
10084                home  directory for  the user  with name  NAME and
10085                project PROJ.
10086 
10087      Action:   Note for system programmer action._sa
10088 
10089 
10090                [create_homedir_.pl1]
10091                create_homedir_:  creating "DIRNAME" for "USERID"
10092 
10093 
10094      Stream:   as (severity0).
10095 
10096      Time:     While system is running.
10097 
10098      Meaning:  The user USERID did not have a home directory.  It
10099                was  created for  him  during  login, or  when his
10100                project's PDT  was installed.  This  is reasonable
10101                if  this  is  the  first  time  he  has logged in.
10102                However, his directory may  have been destroyed by
10103 
10104 
10105 
10106 create_homedir_                175            08/21/20     MR12.7^L
10107 
10108 
10109                the Salvager,  in which case you  have to retrieve
10110                his files.
10111 
10112      Action:   A  retrieval  of  the   user's  directory  may  be
10113                necessary.
10114 
10115 
10116                [create_homedir_.pl1]
10117                create_homedir_:       ERROR_MESSAGE.      DIRNAME
10118                NAME.PROJ
10119 
10120 
10121      Stream:   as (severity0).
10122 
10123      Time:     While system is running.
10124 
10125      Meaning:  An error  occurred while attempting to  create the
10126                home  directory for  the user  with name  NAME and
10127                project PROJ.
10128 
10129      Action:   Note for system programmer action._sa
10130 
10131 
10132                [create_root_dir.pl1]
10133                create_root_dir:      allocating    hash     table
10134                ERROR_MESSAGE
10135 
10136 
10137      Stream:   BOS Typewriter (Crashes system)
10138 
10139      Time:     Cold boot of Multics hierarchy.
10140 
10141      Meaning:  This indicates a logic error in the supervisor, or
10142                CPU  or memory  hardware problems.   An error  has
10143                occurred  allocating the  hash table  for the root
10144                directory.
10145 
10146      Action:   Reboot with a different version of the system.
10147 
10148 
10149                [create_root_dir.pl1]
10150                create_root_dir:  lock error on PPP
10151 
10152 
10153      Stream:   BOS Typewriter (Crashes system)
10154 
10155      Time:     System Intialization.
10156 
10157      Meaning:  The supervisor was unable  to lock the root.  This
10158                indicates a logic error  in the supervisor, or CPU
10159                or memory hardware problems.
10160 
10161      Action:   Follow normal recovery procedures.  $boot_tape
10162 
10163 
10164 create_root_dir                176            08/21/20     MR12.7^L
10165 
10166 
10167 
10168 
10169                [create_root_vtoce.pl1]
10170                create_root_vtoce:  Cannot  alloc-write root vtoce
10171                ERROR_MESSAGE
10172 
10173 
10174      Stream:   BOS Typewriter (Crashes system)
10175 
10176      Time:     Cold boot of Multics hierarchy.
10177 
10178      Meaning:  The system  is unable to write out  the VTOC entry
10179                for the root directory.
10180 
10181      Action:   Correct the disk problem if one exists and reboot.
10182                Otherwise reboot  with a different version  of the
10183                system.
10184 
10185 
10186 
10187                [create_root_vtoce.pl1]
10188                create_root_vtoce:   Cannot set  dmpr bit  map for
10189                root ERROR_MESSAGE
10190 
10191 
10192      Stream:   BOS Typewriter.
10193 
10194      Time:     Cold boot of Multics hierarchy.
10195 
10196      Meaning:  This indicates a logic error in the supervisor, or
10197                CPU or memory hardware problems.
10198 
10199      Action:   Contact the system programming staff.
10200 
10201                Message:     create_root_vtoce:      Cannot    set
10202                root_vtocx in RPV label.
10203 
10204      Stream:   BOS Typewriter (Crashes system)
10205 
10206      Time:     Cold boot of Multics hierarchy.
10207 
10208      Meaning:  The system  is unable to update the  RPV label for
10209                the root directory.
10210 
10211      Action:   Correct the disk problem if one exists and reboot.
10212                Otherwise reboot  with a different version  of the
10213                system.
10214 
10215                Message:    create_root_vtoce:   Root   vtoce  not
10216                allocated at 0, RPV not initialized.
10217 
10218      Stream:   BOS Typewriter (Crashes system)
10219 
10220 
10221 
10222 create_root_vtoce              177            08/21/20     MR12.7^L
10223 
10224 
10225      Time:     Cold boot of Multics hierarchy.
10226 
10227      Meaning:  A  boot -cold  was attempted  without init_vol for
10228                RPV.
10229 
10230      Action:   Reboot  system  answering  the  find_rpv_subsystem
10231                with cold instead of rpv.
10232 
10233 
10234                [create_rpv_partition.pl1]
10235                create_rpv_partition:  Error accessing record NNN.
10236 
10237 
10238      Stream:   BOS Typewriter (Crashes system)
10239 
10240      Time:     System Intialization.
10241 
10242      Meaning:  An i/o error occured  when accessing record NNN of
10243                the rpv while attempting to add a new partition.
10244 
10245      Action:   Try  again.  IF the  error persists, the  rpv will
10246                need to be rebuilt.
10247 
10248 
10249                [create_rpv_partition.pl1]
10250                create_rpv_partition:   No room  in partition  map
10251                for NAME.
10252 
10253 
10254      Stream:   BOS Typewriter (Crashes system)
10255 
10256      Time:     System Intialization.
10257 
10258      Meaning:  The  partition  map  of  the  rpv  was  full.  The
10259                partition could not be added.
10260 
10261      Action:   The rpv will need to be rebuilt.
10262 
10263 
10264                [create_rpv_partition.pl1]
10265                create_rpv_partition:  Out of disk.
10266 
10267 
10268      Stream:   BOS Typewriter (Crashes system)
10269 
10270      Time:     System Intialization.
10271 
10272      Meaning:  Not enough  free space existed  on the rpv  to add
10273                the new partition.
10274 
10275      Action:   The rlv will have to be rebuilt.
10276 
10277 
10278 
10279 
10280 create_rpv_partition           178            08/21/20     MR12.7^L
10281 
10282 
10283                [create_rpv_partition.pl1]
10284                create_rpv_partition:   Paging  region  ends  past
10285                start of high partitions.
10286 
10287 
10288      Stream:   BOS Typewriter (Crashes system)
10289 
10290      Time:     System Intialization.
10291 
10292      Meaning:  An  inconsistency was  found in  the partition map
10293                when adding a new partition to the rpv.
10294 
10295      Action:   The rpv will need to be rebuilt.
10296 
10297 
10298                [create_rpv_partition.pl1]
10299                create_rpv_partition:  Paging  region starts below
10300                end of low partitions.
10301 
10302 
10303      Stream:   BOS Typewriter (Crashes system)
10304 
10305      Time:     System Intialization.
10306 
10307      Meaning:  An  inconsistency was  found in  the partition map
10308                when adding a new partition to the rpv.
10309 
10310      Action:   The rpv will need to be rebuilt.
10311 
10312 
10313                [create_rpv_partition.pl1]
10314                create_rpv_partition:   vtoce  NNN's  file  map is
10315                damaged.  Volume will need salvaging.
10316 
10317 
10318      Stream:   BOS Typewriter (Crashes system)
10319 
10320      Time:     System Intialization.
10321 
10322      Meaning:  The  vtoce  named  was  found  to  be damaged when
10323                adding a new partition to the rpv.
10324 
10325      Action:   Salvage  the  rpv  using  a  boot  of the previous
10326                release.
10327 
10328 
10329                [daemon_user_manager_.pl1]
10330                daemon_user_manager_:      Command     sent     to
10331                daemon_user_manager_ before it was initialized
10332 
10333 
10334      Stream:   as (severity1)
10335 
10336 
10337 
10338 daemon_user_manager_           179            08/21/20     MR12.7^L
10339 
10340 
10341      Time:     In response to an operator command.
10342 
10343      Meaning:  This message  indicates an error in  the Answering
10344                Service or  an incorrect installation.   No daemon
10345                users can log in.
10346 
10347      Action:   Contact the system programming staff.
10348 
10349 
10350                [daemon_user_manager_.pl1]
10351                daemon_user_manager_:   Daemon  init  error.  NAME
10352                PROJ SOURCE REASON
10353 
10354 
10355      Stream:   as (severity2)
10356 
10357      Time:     In response to an operator command.
10358 
10359      Meaning:  The daemon user NAME PROJ  on SOURCE was logged in
10360                correctly  but his  process could  not be started.
10361                The daemon will be logged out.
10362 
10363      Action:   Contact the system programming staff.
10364 
10365 
10366                [daemon_user_manager_.pl1]
10367                daemon_user_manager_:  Daemon will be logged out.
10368 
10369 
10370      Stream:   as (severity1)
10371 
10372      Time:     While system is running.
10373 
10374      Meaning:  An  error in  a daemon  process has  caused it  to
10375                terminate.   The daemon  suffered a  fatal process
10376                error  during  initialization  or  it  has set the
10377                option  which causes  it to  be logged  out when a
10378                fatal process error occurs.
10379 
10380      Action:   Attempt to log in the daemon again and proceed.
10381 
10382 
10383                [daemon_user_manager_.pl1]
10384                daemon_user_manager_:  Error:  CONDITION during OP
10385                for NAME.PROJ SOURCE
10386 
10387 
10388      Stream:   as (severity2)
10389 
10390      Time:     While system is running.
10391 
10392      Meaning:  An unexpected fault has  occurred while the daemon
10393                user manager  was performing an operation  of type
10394 
10395 
10396 daemon_user_manager_           180            08/21/20     MR12.7^L
10397 
10398 
10399                OP  for the  named daemon  process.  An  Answering
10400                Service dump was performed and the system attempts
10401                to continue,  but the daemon process may  be in an
10402                unusable state.
10403 
10404      Action:   Contact the system programming staff.
10405 
10406 
10407                [daemon_user_manager_.pl1]
10408                daemon_user_manager_:  ERROR_MESSAGE.   Logout not
10409                permitted for message coordinator source SOURCE.
10410 
10411 
10412      Stream:   as (severity1)
10413 
10414      Time:     In response to an operator command.
10415 
10416      Meaning:  The  message  coordinator  access  control segment
10417                >system_control_1>mc_acs>SOURCE.mcacs   does   not
10418                permit   the  operator   to  logout   the  daemon.
10419                Therefore, the operator cannot logout the daemon.
10420 
10421      Action:   Contact the system programming staff._sa
10422 
10423 
10424                [daemon_user_manager_.pl1]
10425                daemon_user_manager_:   ERROR_MESSAGE.   NAME.PROJ
10426                SOURCE terminated.
10427 
10428 
10429      Stream:   as (severity1)
10430 
10431      Time:     While system is running.
10432 
10433      Meaning:  An  error in  a daemon  process has  caused it  to
10434                terminate.   A  following  message  will  indicate
10435                whether  a  new  process  has  been  automatically
10436                created.
10437 
10438      Action:   If  the  daemon  is  logged  out, reinitialize the
10439                daemon  and  continue.   Otherwise,  a  new daemon
10440                process  is  created  automatically  and  you  can
10441                continue from there.
10442 
10443 
10444 
10445                [daemon_user_manager_.pl1]
10446                daemon_user_manager_:   ERROR_MESSAGE.  No  MC ACS
10447                segment for message coordinator source SOURCE
10448 
10449 
10450      Stream:   as (severity1)
10451 
10452 
10453 
10454 daemon_user_manager_           181            08/21/20     MR12.7^L
10455 
10456 
10457      Time:     In response to an operator command.
10458 
10459      Meaning:  The  message  coordinator  access  control segment
10460                >system_control_1>mc_acs>SOURCE.mcacs    was   not
10461                found.  It must be created  and given an ACL which
10462                permits  the   operator  to  logout   the  daemon.
10463                Therefore, the operator cannot logout the daemon.
10464 
10465      Action:   Contact the system programming staff._sa
10466 
10467 
10468                [daemon_user_manager_.pl1]
10469                daemon_user_manager_:   Event  entry  called  with
10470                null ev_msg_ptr
10471 
10472 
10473      Stream:   as (severity2)
10474 
10475      Time:     While system is running.
10476 
10477      Meaning:  This indicates an error in the Answering Service.
10478 
10479      Action:   Contact the system programming staff.
10480 
10481 
10482                [daemon_user_manager_.pl1]
10483                daemon_user_manager_:   Fatal  process  error loop
10484                for NAME.PROJ SOURCE.
10485                Daemon will be logged out.
10486 
10487 
10488 
10489      Stream:   as (severity1)
10490 
10491      Time:     While system is running.
10492 
10493      Meaning:  An  error in  a daemon  process has  caused it  to
10494                terminate repeatedly within  the last few minutes.
10495                Detection  of the  loop  causes  the daemon  to be
10496                logged out.
10497 
10498      Action:   Try to login the daemon again.  If it still fails,
10499                notify your System Administrator of the problem.
10500 
10501 
10502 
10503                [daemon_user_manager_.pl1]
10504                daemon_user_manager_:   Invalid  signal  from NAME
10505                PROJ SOURCE
10506                daemon_user_manager_:    signal   was   "XXXXXXXX"
10507                YYY|ZZZZ
10508 
10509 
10510 
10511 
10512 daemon_user_manager_           182            08/21/20     MR12.7^L
10513 
10514 
10515      Stream:   as (severity2)
10516 
10517      Time:     While system is running.
10518 
10519      Meaning:  This  message  may  result  from  an  error in the
10520                Answering Service,  an error in one  of the daemon
10521                processes, or  an attempt by an  unauthorized user
10522                to signal  the daemon user manager.   If the NAME,
10523                PROJ, and SOURCE cannot be determined, the process
10524                ID  of  the  sender  is  shown  instead.   The DUT
10525                (daemon user  table) entry affected is  located at
10526                YYY|ZZZZ in the Answering Service.
10527 
10528                The  signal is  ignored and  the Answering Service
10529                attempts to  continue.  If a daemon  user is named
10530                on the  first line of the message,  this user will
10531                probably be unable to continue.
10532 
10533      Action:   Contact the system programming staff.  If the user
10534                named in the message is  a daemon user, try typing
10535                "logout NAME  PROJ SOURCE", and if  this succeeds,
10536                log the user in again if necessary.
10537 
10538 
10539 
10540                [daemon_user_manager_.pl1]
10541                daemon_user_manager_:      NAME    PROJ     SOURCE
10542                terminated.  Daemon will be logged out.
10543 
10544 
10545      Stream:   as (severity2)
10546 
10547      Time:     While system is running.
10548 
10549      Meaning:  NAME is  the Person_id of the daemon,  PROJ is the
10550                Project_id  of  the  daemon,  and  SOURCE  is  the
10551                Message Coordinator source id  of the daemon.  The
10552                daemon encountered  a fatal process error  and was
10553                logged out to prevent the system from getting into
10554                a loop.
10555 
10556      Action:   Contact the system programming staff.  You can try
10557                logging  the daemon in  again, but if  the process
10558                error is  recurrent the problem must  be corrected
10559                before the daemon will operate successfully.
10560 
10561 
10562 
10563                [daemon_user_manager_.pl1]
10564                daemon_user_manager_:  New process created.
10565 
10566 
10567      Stream:   as (severity1)
10568 
10569 
10570 daemon_user_manager_           183            08/21/20     MR12.7^L
10571 
10572 
10573      Time:     While system is running.
10574 
10575      Meaning:  An  error in  a daemon  process has  caused it  to
10576                terminate.  A new process has been created.
10577 
10578      Action:   A new daemon process  is created automatically and
10579                you can continue from there.
10580 
10581 
10582 
10583                [daemon_user_manager_.pl1]
10584                daemon_user_manager_:    premature  STOPSTOP   for
10585                NAME.PROJ SOURCE
10586 
10587 
10588      Stream:   as (severity0)
10589 
10590      Time:     While system is running.
10591 
10592      Meaning:  This indicates a logic error in the supervisor, or
10593                CPU or memory hardware problems.
10594 
10595      Action:   No operator action is required.
10596 
10597 
10598                [daemon_user_manager_.pl1]
10599                daemon_user_manager_:     process   PERSON.PROJECT
10600                SOURCE ignored trm_ signal.
10601 
10602 
10603      Stream:   as (severity 1)
10604 
10605      Time:     While system is running.
10606 
10607      Meaning:  The  daemon process  PERSON.PROJECT using  message
10608                coordinator SOURCE had been  sent a trm_ signal to
10609                cause process termination, but the process did not
10610                respond  to  the  signal.   The  answering service
10611                proceeds  with the  bump, new_proc,  log out,  etc
10612                operation.
10613 
10614      Action:   No operator action is required.
10615 
10616 
10617                [daemon_user_manager_.pl1]
10618                daemon_user_manager_:     process   PERSON.PROJECT
10619                SOURCE     ignored    wakeup     EVENT_MSG    from
10620                SENDER_PROCESS_ID
10621 
10622 
10623      Stream:   as (severity 1)
10624 
10625      Time:     While system is running.
10626 
10627 
10628 daemon_user_manager_           184            08/21/20     MR12.7^L
10629 
10630 
10631      Meaning:  The  daemon process  PERSON.PROJECT using  message
10632                coordinator  SOURCE had  been sent  a wakeup  with
10633                EVENT_MSG   by   the   process   with   process_id
10634                SENDER_PROCESS_ID.  This event  message is unknown
10635                and will be ignored.
10636 
10637      Action:   No operator action is required.
10638 
10639 
10640                [daemon_user_manager_.pl1]
10641                daemon_user_manager_:  You cannot  new_proc to the
10642                requested authorization.
10643                Cannot  new_proc to  an authorization  outside the
10644                daemon's allowed range.
10645 
10646 
10647 
10648      Stream:   as (severity1)
10649 
10650      Time:     While system is running.
10651 
10652      Meaning:  A  daemon executed  an improper  new_proc command,
10653                trying to change to  an authorization greater than
10654                its  maximum allowed  authorization, or  less than
10655                its minimum allowed authorization, as specified in
10656                the    Person    Name    Table    (PNT),    System
10657                Administrator's  Table  (SAT)  and  Project Master
10658                File  (PMF).   The  new_proc  is  performed at the
10659                original authorization of the process.
10660 
10661      Action:   Contact the system programming staff._sa
10662 
10663 
10664                [dbm_man.pl1]
10665                dbm_man:     attempt    to    initialize   already
10666                initialized map for PV on dskX_NNS
10667 
10668 
10669      Stream:   BOS Typewriter (Crashes system)
10670 
10671      Time:     While system is running.
10672 
10673      Meaning:  This indicates a logic error in the supervisor, or
10674                CPU or memory hardware problems.
10675 
10676      Action:   Follow normal recovery procedures.
10677 
10678 
10679                [dbm_man.pl1]
10680                dbm_man:  bit map  relp not set in pvte  for PV on
10681                dskX_NNS
10682 
10683 
10684 
10685 
10686 dbm_man                        185            08/21/20     MR12.7^L
10687 
10688 
10689      Stream:   BOS Typewriter (Crashes system)
10690 
10691      Time:     While system is running.
10692 
10693      Meaning:  This indicates a logic error in the supervisor, or
10694                CPU or memory hardware problems.
10695 
10696      Action:   Follow normal recovery procedures.
10697 
10698 
10699                [dbm_man.pl1]
10700                dbm_man:  Cannot get ASTE for dbm_seg
10701 
10702 
10703      Stream:   BOS Typewriter (Crashes system)
10704 
10705      Time:     System Intialization.
10706 
10707      Meaning:  The  system was unable  to create the  dbm_seg and
10708                obtain an ASTE for this segment.
10709 
10710      Action:   Contact the system programming staff._sa
10711 
10712 
10713                [dbm_man.pl1]
10714                dbm_man:  csl failure
10715 
10716 
10717      Stream:   Logged in SYSERR log.
10718 
10719      Time:     While system is running.
10720 
10721      Meaning:  The CSL instruction appears  to have failed on one
10722                of the processors.
10723 
10724      Action:   No operator action is required.
10725 
10726 
10727                [dbm_man.pl1]
10728                dbm_man:  unable to allocate dumper bit map for PV
10729                on dskX_NNS
10730 
10731 
10732      Stream:   BOS Typewriter (Crashes system)
10733 
10734      Time:     While system is running.
10735 
10736      Meaning:  The system was unable to allocate a dumper bit map
10737                in dbm_seg  for the volume on  dskX_NNS.  Too many
10738                volumes  are online,  or there  is something wrong
10739                with the volume header.
10740 
10741      Action:   Follow normal recovery procedures.
10742 
10743 
10744 dbm_man                        186            08/21/20     MR12.7^L
10745 
10746 
10747 
10748 
10749                [dbm_man.pl1]
10750                dbm_man:  unable to initialize area:  ERROR_MESS
10751 
10752 
10753      Stream:   BOS Typewriter (Crashes system)
10754 
10755      Time:     While system is running.
10756 
10757      Meaning:  This indicates a logic error in the supervisor, or
10758                CPU or memory hardware problems.
10759 
10760      Action:   Follow normal recovery procedures.
10761 
10762 
10763                [deactivate_for_demount.pl1]
10764                deactivate_for_demount:  Error  freeing vtocx OOOO
10765                on dskX_NN for UID.  ERRORMESSAGE.
10766 
10767 
10768      Stream:   Logged in SYSERR log.
10769 
10770      Time:     During system shutdown.
10771 
10772      Meaning:  The  VTOCE for  a deciduous  segment could  not be
10773                freed for the reason indicated.  The VTOCE will be
10774                freed   by   the   next   volume   salvage  or  by
10775                delete_old_pdds.
10776 
10777      Action:   No operator action is required.
10778 
10779 
10780                [deactivate_segs.pl1]
10781                deactivate_segs:  unflushed trailer
10782 
10783 
10784      Stream:   BOS Typewriter (Crashes system)
10785 
10786      Time:     While system is running.
10787 
10788      Meaning:  After destroying a process,  the system found that
10789                some system trailer (specifying connection of that
10790                process  to some  segment) still  exists for  that
10791                process  in  str_seg.   This  indicates  that some
10792                segment  was  improperly   disconnected  from  the
10793                process at some time.This  indicates a logic error
10794                in  the  supervisor,  or  CPU  or  memory hardware
10795                problems.
10796 
10797      Action:   Follow normal recovery procedures.
10798 
10799 
10800 
10801 
10802 debug_check                    187            08/21/20     MR12.7^L
10803 
10804 
10805 
10806 
10807                [debug_check.pl1]
10808                debug_check:  too many parameters on parm cards
10809 
10810 
10811      Stream:   BOS Typewriter.
10812 
10813      Time:     System Intialization.
10814 
10815      Meaning:  A  total of  14 options  may be  specified on PARM
10816                cards.   This limit   has been  exceeded.  Options
10817                after the 14th will be ignored.
10818 
10819      Action:   Correct  the configuration   deck before  the next
10820                bootload.
10821 
10822 
10823 
10824                [obs_reconfigure.pl1]
10825                delcpu:  Cannot stop CPU X.
10826 
10827 
10828      Stream:   Initializer process output.
10829 
10830      Time:     In response to an operator command.
10831 
10832      Meaning:  CPU X did not respond  to a command to stop within
10833                the expected time.  The  CPU may be malfunctioning
10834                or in STEP, or it may be in a very tight loop.
10835 
10836      Action:   Check the CPU panel.   If the processor appears to
10837                be in a  loop, it may be possible to  break it out
10838                by  placing zeros  in the  processor switches  and
10839                using  the EXECUTE  button to  cause a  fault; but
10840                this action sometimes causes  the system to crash,
10841                depending on where the loop is.
10842 
10843 
10844 
10845                [obs_reconfigure.pl1]
10846                delcpu:  CPU X is not online.
10847 
10848 
10849      Stream:   Initializer process output.
10850 
10851      Time:     In response to an operator command.
10852 
10853      Meaning:  A  delcpu X  command finds  that CPU  X is already
10854                deleted.
10855 
10856      Action:   No operator action is required.
10857 
10858 
10859 
10860 delcpu                         188            08/21/20     MR12.7^L
10861 
10862 
10863 
10864 
10865                [obs_reconfigure.pl1]
10866                delcpu:  CPU X is the only CPU.
10867 
10868 
10869      Stream:   Initializer process output.
10870 
10871      Time:     In response to an operator command.
10872 
10873      Meaning:  A  delcpu X command  attempted to delete  the last
10874                CPU.  No action was taken.
10875 
10876      Action:   No operator action is required.
10877 
10878 
10879                [obs_reconfigure.pl1]
10880                delcpu:   Illegal command or  subroutine argument.
10881                BLAH
10882 
10883 
10884      Stream:   Initializer process output.
10885 
10886      Time:     In response to an operator command.
10887 
10888      Meaning:  Invalid input was typed.
10889 
10890      Action:   Enter a corrected command line.
10891 
10892 
10893                [obs_reconfigure.pl1]
10894                delcpu:  Reconfiguration database is locked.
10895 
10896 
10897      Stream:   Initializer process output.
10898 
10899      Time:     In response to an operator command.
10900 
10901      Meaning:  Another  process   is  performing  reconfiguration
10902                currently, or  a fault during  reconfiguration has
10903                left the reconfiguration tables locked.
10904 
10905      Action:   If  it  is  certain   that  no  other  process  is
10906                reconfiguring,   and   that    the   fault   which
10907                interrupted  reconfiguration has  been cured,  the
10908                reconfigure$force_unlock  command may  be used  to
10909                clear the lock at the direction of system staff.
10910 
10911 
10912 
10913                [obs_reconfigure.pl1]
10914                delcpu:  Wrong number of arguments supplied.
10915 
10916 
10917 
10918 delcpu                         189            08/21/20     MR12.7^L
10919 
10920 
10921      Stream:   Initializer process output.
10922 
10923      Time:     In response to an operator command.
10924 
10925      Meaning:  Invalid input was typed.
10926 
10927      Action:   Enter a corrected command line.
10928 
10929 
10930                [delentry.pl1]
10931                delentry:  deleting damaged dir PATH for USERID
10932 
10933 
10934      Stream:   Logged in SYSERR log.
10935 
10936      Time:     While system is running.
10937 
10938      Meaning:  An  attempt to delete  a directory found  that the
10939                directory  header had  a zero  UID.  The directory
10940                was deleted anyway.
10941 
10942      Action:   No operator action is required.
10943 
10944 
10945                [delentry.pl1]
10946                delentry:   error  from  hash$out  on  "NAME"  for
10947                USERID.  ERROR_CODE
10948 
10949 
10950      Stream:   Logged in SYSERR log.
10951 
10952      Time:     While system is running.
10953 
10954      Meaning:  An attempt to delete the  entry name NAME from the
10955                directory  hash table   failed.  This  indicates a
10956                logic  error in the  supervisor, or CPU  or memory
10957                hardware problems.
10958 
10959      Action:   No operator action is required.
10960 
10961 
10962                [delentry.pl1]
10963                delentry:   error  from   terminate_  for  USERID.
10964                ERROR_CODE
10965 
10966 
10967      Stream:   Logged in SYSERR log.
10968 
10969      Time:     While system is running.
10970 
10971      Meaning:  An error code was returned  while trying to make a
10972                directory   unknown  while   deleting  it.    This
10973 
10974 
10975 
10976 delentry                       190            08/21/20     MR12.7^L
10977 
10978 
10979                indicates a logic error  in the supervisor, or CPU
10980                or memory hardware problems.
10981 
10982      Action:   No operator action is required.
10983 
10984 
10985                [delentry.pl1]
10986                delentry:   priv_dfile  error  deleting  vtoce for
10987                PATH for USERID.  ERROR_CODE
10988 
10989 
10990      Stream:   Logged in SYSERR log.
10991 
10992      Time:     While system is running.
10993 
10994      Meaning:  A privileged call to delete a segment discovered a
10995                branch  with not  VTOC entry.   This situation  is
10996                called  a "connection   failure."  The  branch was
10997                deleted anyway.
10998 
10999      Action:   No operator action is required.
11000 
11001 
11002                [delete_vtoce.pl1]
11003                delete_vtoce:    cannot   add   time/page  product
11004                (SEGTPP  DIRTPP) to  pvid  PPP  vtocx VVV  uid UUU
11005                ERRORMESSAGE
11006 
11007 
11008 
11009      Stream:   Logged in SYSERR log.
11010 
11011      Time:     While system is running.
11012 
11013      Meaning:  During  the deletion  of a  directory which  had a
11014                quota  account, a   difficulty was  encountered in
11015                reflecting  its time/page product  upward.  SEGTPP
11016                and DIRTPP are the  time/page product for segments
11017                and directories, respectively.
11018 
11019      Action:   Contact the system programming staff._sa
11020 
11021 
11022                [delete_vtoce.pl1]
11023                delete_vtoce:  from  quotaw, pvid PPP.   vtocx VVV
11024                ERRORMESSAGE
11025 
11026 
11027      Stream:   Logged in SYSERR log.
11028 
11029      Time:     While system is running.
11030 
11031 
11032 
11033 
11034 delete_vtoce                   191            08/21/20     MR12.7^L
11035 
11036 
11037      Meaning:  While  deleting  a  directory  which  had  a quota
11038                account, a  quota handling problem  usually record
11039                quota overflow, was encountered.
11040 
11041      Action:   No operator action is required.
11042 
11043 
11044                [obs_reconfigure.pl1]
11045                Deleted CPU X.
11046 
11047 
11048      Stream:   Initializer process output.
11049 
11050      Time:     In response to an operator command.
11051 
11052      Meaning:  This  is the  response  to  a successful  delcpu X
11053                command.
11054 
11055      Action:   No operator action is required.
11056 
11057 
11058                [obs_reconfigure.pl1]
11059                delmain:  Abs wired pages in memory.
11060 
11061 
11062      Stream:   Initializer process output.
11063 
11064      Time:     In response to an operator command.
11065 
11066      Meaning:  A delmain  command attempted to delete  a range of
11067                pages  which included  some pages  which cannot be
11068                deleted.  No action was taken.
11069 
11070      Action:   Enter a corrected command line.
11071 
11072 
11073                [obs_reconfigure.pl1]
11074                delmain:  Illegal command  or subroutine argument.
11075                BLAH
11076 
11077 
11078      Stream:   Initializer process output.
11079 
11080      Time:     In response to an operator command.
11081 
11082      Meaning:  Invalid input was typed.
11083 
11084      Action:   Enter a corrected command line.
11085 
11086 
11087                [obs_reconfigure.pl1]
11088                delmain:  Not enough main memory left.
11089 
11090 
11091 
11092 delmain                        192            08/21/20     MR12.7^L
11093 
11094 
11095      Stream:   Initializer process output.
11096 
11097      Time:     In response to an operator command.
11098 
11099      Meaning:  A  delmain  command  attempted  to  delete so much
11100                memory that the system would be unable to function
11101                correctly.  No action was taken.
11102 
11103      Action:   Enter a corrected command line.
11104 
11105 
11106                [obs_reconfigure.pl1]
11107                delmain:  Reconfiguration database is locked.
11108 
11109 
11110      Stream:   Initializer process output.
11111 
11112      Time:     In response to an operator command.
11113 
11114      Meaning:  Another  process   is  performing  reconfiguration
11115                currently, or  a fault during  reconfiguration has
11116                left the reconfiguration tables locked.
11117 
11118      Action:   If  it  is  certain   that  no  other  process  is
11119                reconfiguring,   and   that    the   fault   which
11120                interrupted  reconfiguration has  been cured,  the
11121                reconfigure$force_unlock  command may  be used  to
11122                clear the lock at the direction of system staff.
11123 
11124 
11125 
11126                [obs_reconfigure.pl1]
11127                delmain:  Request is not  within range of a single
11128                controller.  MAIN XXX
11129 
11130 
11131      Stream:   Initializer process output.
11132 
11133      Time:     In response to an operator command.
11134 
11135      Meaning:  A  delmain command must  specify a range  of pages
11136                which lies  completely within one  controller.  No
11137                action was taken.
11138 
11139      Action:   Enter a corrected command line.
11140 
11141 
11142                [obs_reconfigure.pl1]
11143                delmain:  Wrong number of arguments supplied.
11144 
11145 
11146      Stream:   Initializer process output.
11147 
11148 
11149 
11150 delmain                        193            08/21/20     MR12.7^L
11151 
11152 
11153      Time:     In response to an operator command.
11154 
11155      Meaning:  Invalid input was typed.
11156 
11157      Action:   Enter a corrected command line.
11158 
11159 
11160                [obs_reconfigure.pl1]
11161                delmem:  Abs wired pages in MEM Y.
11162 
11163 
11164      Stream:   Initializer process output.
11165 
11166      Time:     In response to an operator command.
11167 
11168      Meaning:  An  attempt  was  made  to  delete  a memory which
11169                included some  pages which cannot be  deleted.  No
11170                action was taken.
11171 
11172      Action:   The memory cannot be deleted.
11173 
11174 
11175                [obs_reconfigure.pl1]
11176                delmem:   Illegal command or  subroutine argument.
11177                BLAH
11178 
11179 
11180      Stream:   Initializer process output.
11181 
11182      Time:     In response to an operator command.
11183 
11184      Meaning:  Invalid input was typed.
11185 
11186      Action:   Enter a corrected command line.
11187 
11188 
11189                [obs_reconfigure.pl1]
11190                delmem:  MEM Y is not online.
11191 
11192 
11193      Stream:   Initializer process output.
11194 
11195      Time:     In response to an operator command.
11196 
11197      Meaning:  A delmem Y command was typed but no such memory is
11198                in use.
11199 
11200      Action:   No operator action is required.
11201 
11202 
11203                [obs_reconfigure.pl1]
11204                delmem:  Not enough main memory to remove MEM Y.
11205 
11206 
11207 
11208 delmem                         194            08/21/20     MR12.7^L
11209 
11210 
11211      Stream:   Initializer process output.
11212 
11213      Time:     In response to an operator command.
11214 
11215      Meaning:  The system  would be unable to  function correctly
11216                if SCU  Y and its memory were  deleted.  No action
11217                was taken.
11218 
11219      Action:   Try something else.
11220 
11221 
11222                [obs_reconfigure.pl1]
11223                delmem:  Reconfiguration database is locked.
11224 
11225 
11226      Stream:   Initializer process output.
11227 
11228      Time:     In response to an operator command.
11229 
11230      Meaning:  Another  process   is  performing  reconfiguration
11231                currently, or  a fault during  reconfiguration has
11232                left the reconfiguration tables locked.
11233 
11234      Action:   If  it  is  certain   that  no  other  process  is
11235                reconfiguring,   and   that    the   fault   which
11236                interrupted  reconfiguration has  been cured,  the
11237                reconfigure$force_unlock  command may  be used  to
11238                clear the lock at the direction of system staff.
11239 
11240 
11241 
11242                [add_scu.pl1]
11243                delmem:  Removed MEM X.
11244 
11245 
11246      Stream:   BOS Typewriter.
11247 
11248      Time:     In response to an operator command.
11249 
11250      Meaning:  The system control unit X has been deleted.
11251 
11252      Action:   No operator action is required.
11253 
11254 
11255                [obs_reconfigure.pl1]
11256                delmem:  Wrong number of arguments supplied.
11257 
11258 
11259      Stream:   Initializer process output.
11260 
11261      Time:     In response to an operator command.
11262 
11263      Meaning:  Invalid input was typed.
11264 
11265 
11266 delmem                         195            08/21/20     MR12.7^L
11267 
11268 
11269      Action:   Enter a corrected command line.
11270 
11271 
11272                [demount_pv.pl1]
11273                demount_pv:  ast out of sync
11274 
11275 
11276      Stream:   BOS Typewriter (Crashes system)
11277 
11278      Time:     Volume demounting or system shutdown.
11279 
11280      Meaning:  The  volume  demounter  has  detected  irreparable
11281                damage to the system segment table (SST).
11282 
11283      Action:   Emergency  shutdown  will  fail,  and  need not be
11284                attempted.  Follow normal  recovery procedures for
11285                ESD failure.
11286 
11287 
11288 
11289                [demount_pv.pl1]
11290                demount_pv:     ioi_PROGNAME     for    DRIVENAME:
11291                ERRORMESSAGE
11292 
11293 
11294      Stream:   BOS Typewriter.
11295 
11296      Time:     Volume demounting.
11297 
11298      Meaning:  In  attempting to  cycle down  drive DRIVENAME, an
11299                unexpected  error   was  received  from   the  I/O
11300                Interfacer.  The drive may not be cycled down.
11301 
11302      Action:   Notify the  system programming staff.   Cycle down
11303                the drive if it was not cycled down.
11304 
11305 
11306                [demount_pv.pl1]
11307                demount_pv:     vtoc    cleanup    of   DRIVENAME:
11308                ERRORMESSAGE
11309 
11310 
11311      Stream:   BOS Typewriter.
11312 
11313      Time:     Volume demounting or shutdown.
11314 
11315      Meaning:  An  unexpected error  was encountered  in flushing
11316                VTOC information  out to a volume  being shut down
11317                or demounted.   The volume will not  be demounted.
11318                message.
11319 
11320      Action:   Contact the system  programming staff.  Attempt to
11321                repeat the demount of  the logical volume, if this
11322 
11323 
11324 demount_pv                     196            08/21/20     MR12.7^L
11325 
11326 
11327                is  not  during  shutdown.   The  physical  volume
11328                involved may have to be salvaged.
11329 
11330 
11331 
11332                [demount_pv.pl1]
11333                demounted DRIVENAME
11334 
11335 
11336      Stream:   BOS Typewriter.
11337 
11338      Time:     Volume   demounting,  in  response   to  delete_lv
11339                command or user action.
11340 
11341      Meaning:  The disk pack on  drive DRIVENAME was successfully
11342                demounted.
11343 
11344      Action:   No operator action is required.
11345 
11346 
11347                [disk_table_.pl1]
11348                demounted lv LVNAME
11349 
11350 
11351      Stream:   Initializer process output.
11352 
11353      Time:     While system is running.
11354 
11355      Meaning:  The  demount  of  the  logical  volume  LVNAME  is
11356                complete.
11357 
11358      Action:   No operator action is required.
11359 
11360 
11361                [device_acct_.pl1]
11362                device_acct_$init:  ERROR_MESSAGE.  device_table
11363 
11364 
11365      Stream:   as (severity 2)
11366 
11367      Time:     System Intialization.
11368 
11369      Meaning:  An   error   occurred   which   initializing   the
11370                device_table.     ERROR_MESSAGE   is    the   text
11371                associated  with  the  error  code  describing the
11372                error.  Device accounting  is disabled, and system
11373                initialization fails.
11374 
11375      Action:   Contact the system programming staff.
11376 
11377 
11378                [device_acct_.pl1]
11379 
11380 
11381 
11382 device_acct_$off               197            08/21/20     MR12.7^L
11383 
11384 
11385                device_acct_$off:    device   N   (ACCT_TYPE_NAME,
11386                DEV_NAME) not in device table for PERSON.PROJECT
11387 
11388 
11389      Stream:   as (severity 0)
11390 
11391      Time:     While system is running.
11392 
11393      Meaning:  Device DEV_NAME, which  has device accounting type
11394                number  N associated with  ACCT_TYPE_NAME devices,
11395                was  not found   in PERSON.PROJECT's  device table
11396                entries.  Probable  cause is damage to  the device
11397                table.
11398 
11399      Action:   Contact the system programming staff._sa
11400 
11401 
11402                [device_acct_.pl1]
11403                device_acct_:   deve.pdtep (PTR1) not  = ute.pdtep
11404                (PTR2) for PERSON.PROJECT.
11405 
11406 
11407      Action:   as (severity 2)
11408 
11409      Time:     While system is running.
11410 
11411      Meaning:  The Project Definition  Table entry pointer (PTR1)
11412                stored  in  the  device  table  for PERSON.PROJECT
11413                differs from the PDT  entry pointer stored in that
11414                user's  User Table   Entry (UTE).This  indicates a
11415                logic  error in the  supervisor, or CPU  or memory
11416                hardware problems.
11417 
11418      Action:   Contact the system programming staff.
11419 
11420 
11421                [device_acct_.pl1]
11422                device_acct_:  ERROR_MESSAGE.   Attempting to lock
11423                PDT entry of PERSON.PROJECT
11424 
11425 
11426      Stream:   as (severity 2)
11427 
11428      Time:     While system is running.
11429 
11430      Meaning:  An attempt was made to lock the Project Definition
11431                Table  (PDT) entry   for PERSON.PROJECT  to update
11432                device  usage charges  for the  user.  Locking did
11433                not succeed within 15 seconds, so the charges were
11434                not  updated.  If  the attempt  occurred during an
11435                accounting  update, the  charges will  continue to
11436                accrue  until  the  next  update,  at  which  time
11437                locking the PDT entry  is again attempted.  If the
11438 
11439 
11440 device_acct_                   198            08/21/20     MR12.7^L
11441 
11442 
11443                original attempt  occurred as part of  a logout or
11444                new_proc operation, the device charges are lost.
11445 
11446      Action:   Contact the system programming staff._sa
11447 
11448 
11449                [page_error.alm]
11450                device_control:  invalid pvtx XX
11451 
11452 
11453      Stream:   BOS Typewriter (Crashes system)
11454 
11455      Time:     While system is running.
11456 
11457      Meaning:  An  invalid  PVT  index  XX  was  found  by device
11458                control, or an invalid device type appeared in the
11459                PVT entry  of that index.  This  indicates a logic
11460                error in the supervisor, or CPU or memory hardware
11461                problems.
11462 
11463      Action:   Follow normal recovery procedures.
11464 
11465 
11466                [page_error.alm]
11467                device_control:  invalid pvtx XX
11468 
11469 
11470      Stream:   BOS Typewriter (Crashes system)
11471 
11472      Time:     While system is running.
11473 
11474      Meaning:  An  invalid  PVT  index  XX  was  found  by device
11475                control, or an invalid device type appeared in the
11476                PVT entry  of that index.  This  indicates a logic
11477                error in the supervisor, or CPU or memory hardware
11478                problems.
11479 
11480      Action:   Follow normal recovery procedures.
11481 
11482 
11483                [dial_ctl_.pl1]
11484                dial_ctl_:   Autocall   channel  CHANNEL  declared
11485                multi-class,     but      does     not     support
11486                set_required_access_class.
11487 
11488 
11489      Stream:   as (severity2)
11490 
11491      Time:     While system is running._
11492 
11493      Meaning:  The  autocall channel   CHANNEL has  been declared
11494                multi-class  in   the  CDT,  but   the  underlying
11495                multiplexer      does     not      support     the
11496 
11497 
11498 dial_ctl_                      199            08/21/20     MR12.7^L
11499 
11500 
11501                set_required_access_class   control  order.    The
11502                channel  should be  defined as  single class.  The
11503                user's dial out request was refused.
11504 
11505      Action:   Contact the system programming staff._sa
11506 
11507 
11508                [dial_ctl_.pl1]
11509                dial_ctl_:  Can't find process WWWWWWWWWWW
11510 
11511 
11512      Stream:   as (severity0)
11513 
11514      Time:     While system is running.
11515 
11516      Meaning:  An  invalid signal  was received  by the secondary
11517                terminal manager.
11518 
11519      Action:   Note for system programmer action.
11520 
11521 
11522                [dial_ctl_.pl1]
11523                dial_ctl_:  Channel CHANNEL (AIM_CLASS, SERV_TYPE)
11524                hung up on Initializer
11525 
11526 
11527      Stream:   as (severity1)
11528 
11529      Time:     While system is running.
11530 
11531      Meaning:  The  channel CHANNEL  with access  class AIM_CLASS
11532                and  service  type  SERV_TYPE  hung  up.   It  had
11533                previously been dialed to the Initializer.
11534 
11535      Action:   No operator action is required.
11536 
11537 
11538                [dial_ctl_.pl1]
11539                dial_ctl_:  Channel CHANNEL (AIM_CLASS, SERV_TYPE)
11540                hung up on missing process WWWWWWWWWWWW
11541 
11542 
11543      Stream:   as (severity1)
11544 
11545      Time:     While system is running.
11546 
11547      Meaning:  The  channel CHANNEL  with access  class AIM_CLASS
11548                and service  type SERV_TYPE hung up.   It had been
11549                dialed  to  a  process,   but  the  system  cannot
11550                determine what  process it had been  connected to.
11551                The process may have  terminated before the hangup
11552                was detected.
11553 
11554 
11555 
11556 dial_ctl_                      200            08/21/20     MR12.7^L
11557 
11558 
11559      Action:   If  this  happens  often,  inform  the programming
11560                staff.
11561 
11562 
11563                [dial_ctl_.pl1]
11564                dial_ctl_:  Channel CHANNEL  dialed to Initializer
11565                {(PERSON.PROJECT)}
11566 
11567 
11568      Stream:   as (severity2)
11569 
11570      Time:     While system is running.
11571 
11572      Meaning:  An additional secondary terminal has been attached
11573                to the  Initializer process as a result  of a dial
11574                system command.  CHANNEL  specifies which terminal
11575                dialed Initializer.
11576 
11577      Action:   If  this  terminal  has   been  connected  to  the
11578                Initializer  by  an  authorized  operations  staff
11579                member, proceed  to use it by  issuing an "accept"
11580                command  and possibly  the "substty"  command.  If
11581                this  is  an  invalid  attempt  to  connect to the
11582                system,  type  "drop  CHANNEL"  to  disconnect the
11583                terminal.
11584 
11585 
11586 
11587                [dial_ctl_.pl1]
11588                dial_ctl_:  Channel CHANNEL hung up after dial_out
11589                for PERSON.PROJECT
11590 
11591 
11592      Stream:   as (severity0)
11593 
11594      Time:     While system is running.
11595 
11596      Meaning:  During   a   dial_out   of   channel   CHANNEL  by
11597                PERSON.PROJECT, the channel hung up.  The dial_out
11598                attempt was aborted.
11599 
11600      Action:   No operator action is required.
11601 
11602 
11603                [dial_ctl_.pl1]
11604                dial_ctl_:  Dialing channel CHANNEL (ACC_CLASS) to
11605                DESTINATION   for   PERSON.PROJECT   {using   comm
11606                privilege}
11607 
11608 
11609      Stream:   as (severity0)
11610 
11611      Time:     While system is running.
11612 
11613 
11614 dial_ctl_                      201            08/21/20     MR12.7^L
11615 
11616 
11617      Meaning:  The  user PERSON.PROJECT  is dialing  out on  dial
11618                channel CHANNEL with access class ACC_CLASS to the
11619                destination DESTINATION.  If this log message ends
11620                with  "using  comm  privilege",  then  the process
11621                dialing  out  has  used   the  comm  privilege  to
11622                circumvent AIM restrictions.
11623 
11624      Action:   No operator action is required.
11625 
11626 
11627                [dial_ctl_.pl1]
11628                dial_ctl_:            ERROR_MESSAGE           From
11629                get_required_access_class control order on channel
11630                CHANNEL.
11631 
11632 
11633      Stream:   as (severity0)
11634 
11635      Time:     While system is running.
11636 
11637      Meaning:  While attempting to  determine whether the channel
11638                CHANNEL had any  access class restrictions imposed
11639                on it by the hardcore, ERROR_MESSAGE was returned.
11640                The request in progress was aborted.
11641 
11642      Action:   Note for system programmer action.
11643 
11644 
11645                [dial_ctl_.pl1]
11646                dial_ctl_:  ERROR_MESSAGE.  Can't  find PNT entry:
11647                PERSON_ID
11648 
11649 
11650      Stream:   as (severity2)
11651 
11652      Time:     While system is running.
11653 
11654      Meaning:  An attempt was made to  find the Person Name Table
11655                entry  of  the  PERSON_ID   specified  in  a  dial
11656                preaccess  command.   However,  an  error occurred
11657                which searching in the PNT.
11658 
11659      Action:   Contact the system programming staff._sa
11660 
11661 
11662                [dial_ctl_.pl1]
11663                dial_ctl_:  ERROR_MESSAGE.   dial_out (CHANNEL for
11664                PERSON.PROJECT) failed.
11665 
11666 
11667      Stream:   as (severity0)
11668 
11669      Time:     While system is running.
11670 
11671 
11672 dial_ctl_                      202            08/21/20     MR12.7^L
11673 
11674 
11675      Meaning:  While attempting  to dial_out channel  CHANNEL for
11676                PERSON.PROJECT,  the error  ERROR_MESSAGE occured.
11677                The dial_out attempt was aborted.
11678 
11679      Action:   No operator action is required.
11680 
11681 
11682                [dial_ctl_.pl1]
11683                dial_ctl_:   ERROR_MESSAGE.  after  dial_out order
11684                (CHANNEL for PERSON.PROJECT)
11685 
11686 
11687      Stream:   as (severity0)
11688 
11689      Time:     While system is running.
11690 
11691      Meaning:  The user  PERSON.PROJECT is attempting  a dial_out
11692                of  channel CHANNEL.   The dial_out  control order
11693                produced  the error  ERROR_MESSAGE.  The  dial_out
11694                attempt is aborted.
11695 
11696      Action:   Note for system programmer action.
11697 
11698 
11699                [dial_ctl_.pl1]
11700                dial_ctl_:   ERROR_MESSAGE.  Attempting  to detach
11701                CHANNEL from PERSON.PROJECT
11702 
11703 
11704      Stream:   as (severity0)
11705 
11706      Time:     While system is running.
11707 
11708      Meaning:  An  attempt  to  disconnect  channel  CHANNEL from
11709                PERSON.PROJECT  failed.    ERROR_MESSAGE  explains
11710                why.
11711 
11712      Action:   Note for system programmer action.
11713 
11714 
11715                [dial_ctl_.pl1]
11716                dial_ctl_:       ERROR_MESSAGE.       call      to
11717                astty_$tty_new_proc of  CHANNEL for PERSON.PROJECT
11718                failed
11719 
11720 
11721      Stream:   as (severity0)
11722 
11723      Time:     While system is running.
11724 
11725      Meaning:  An  attempt  to  connect  the  channel  CHANNEL to
11726                PERSON.PROJECT  failed.   ERROR_MESSAGE  indicates
11727                why.
11728 
11729 
11730 dial_ctl_                      203            08/21/20     MR12.7^L
11731 
11732 
11733      Action:   Contact the system programming staff._sa
11734 
11735 
11736                [dial_ctl_.pl1]
11737                dial_ctl_:  ERROR_MESSAGE.  Could not check access
11738                to >sc1>admin_acs>tandd.acs for PERSON.PROJECT.
11739 
11740 
11741      Stream:   as (severity0)
11742 
11743      Time:     While system is running.
11744 
11745      Meaning:  The user PERSON.PROJECT  attempted to tandd_attach
11746                a  communications  channel.    This  operation  is
11747                controlled  by  rw  access   to  the  ACS  segment
11748                specified.   For  the  reason  ERROR_MESSAGE,  the
11749                answering  service could  not check  access to the
11750                segment.    The  user  tandd_attach   request  was
11751                refused.
11752 
11753      Action:   Contact the system programming staff._sa
11754 
11755 
11756                [dial_ctl_.pl1]
11757                dial_ctl_:          ERROR_MESSAGE.         getting
11758                dial_out_status   or   tty   info   (CHANNEL   for
11759                PERSON.PROJECT)
11760 
11761 
11762      Stream:   as (severity0)
11763 
11764      Time:     While system is running.
11765 
11766      Meaning:  During   a   dial_out   of   channel   CHANNEL  by
11767                PERSON.PROJECT,   the   error   ERROR_MESSAGE  was
11768                returned  while  attempting  to  determine  if the
11769                dial_out control order succeeded or failed.
11770 
11771      Action:   No operator action is required.
11772 
11773 
11774                [dial_ctl_.pl1]
11775                dial_ctl_:   ERROR_MESSAGE.  Issuing  tandd_attach
11776                control order for channel CHAN
11777 
11778 
11779      Stream:   as (severity0)
11780 
11781      Time:     While system is running.
11782 
11783      Meaning:  The user PERSON.PROJECT  attempted to tandd_attach
11784                a  communications  channel  which  failed  for the
11785 
11786 
11787 
11788 dial_ctl_                      204            08/21/20     MR12.7^L
11789 
11790 
11791                reason   given   by   ERROR_MESSAGE.    The   user
11792                tandd_attach request was refused.
11793 
11794      Action:   Contact the system programming staff._sa
11795 
11796 
11797                [dial_ctl_.pl1]
11798                dial_ctl_:  ndialed negative CHANNEL
11799 
11800 
11801      Stream:   as (severity0)
11802 
11803      Time:     While system is running.
11804 
11805      Meaning:  The count  of secondary consoles for a  user is in
11806                error.  A  terminal is hanging up  which claims to
11807                be attached  to a user  but his count  of attached
11808                terminals is zero.
11809 
11810      Action:   Note for system programmer action.
11811 
11812 
11813                [dial_ctl_.pl1]
11814                dial_ctl_:              Program             error.
11815                as_request_sender.version (N) not  correct in dial
11816                request.  Should be M.
11817 
11818 
11819      Stream:   as (severity1)
11820 
11821      Time:     While system is running.
11822 
11823      Meaning:  There is a mismatch in  the version number used by
11824                the the programs  as_request_server_ and dial_ctl_
11825                for the as_request_sender_ structure.
11826 
11827      Action:   Contact the system programming staff.
11828 
11829 
11830                [dial_ctl_.pl1]
11831                dial_ctl_:     Refused   unknown    request   from
11832                PERSON.PROJECT; ERROR_MESSAGE REASON
11833 
11834 
11835      Stream:   as (severity0)
11836 
11837      Time:     While system is running.
11838 
11839      Meaning:  PERSON.PROJECT send  a dial_server request  to the
11840                Initializer  of unknown  format.  It  was rejected
11841                for  the reasons   specified in  ERROR_MESSAGE and
11842                REASON.
11843 
11844 
11845 
11846 dial_ctl_                      205            08/21/20     MR12.7^L
11847 
11848 
11849 
11850 
11851                [dial_ctl_.pl1]
11852                dial_ctl_:    Rejected    unknown   request   from
11853                PERSON.PROJECT.    No   request   flags   set   in
11854                dial_server_request.
11855 
11856 
11857      Stream:   as (severity0)
11858 
11859      Time:     While system is running.
11860 
11861      Meaning:  The  user  PERSON.PROJECT  attempted  to  send  an
11862                dial_server request to the Initializer, but failed
11863                to specify what type of request he/she wanted.
11864 
11865      Action:   No operator action is required.
11866 
11867 
11868                [dial_ctl_.pl1]
11869                dial_ctl_:    sat.ht  has   PROJECT_ID,  sat   has
11870                OTHER_PROJECT_ID at LOC.
11871 
11872 
11873      Stream:   as (severity2)
11874 
11875      Time:     While system is running.
11876 
11877      Meaning:  The  System Administrator's Table  is inconsistent
11878                with the location information in its hash table.
11879 
11880      Action:   Contact the system programming staff._sa
11881 
11882 
11883                [dial_ctl_.pl1]
11884                dial_ctl_:  Tracing turned off
11885 
11886 
11887      Stream:   as (severity1)
11888 
11889      Time:     While system is running.
11890 
11891      Meaning:  A  system  administrator  has  disabled  dial_ctl_
11892                tracing.
11893 
11894      Action:   No operator action is required.
11895 
11896 
11897                [dial_ctl_.pl1]
11898                dial_ctl_:  Tracing turned on.
11899 
11900 
11901      Stream:   as (severity1)
11902 
11903 
11904 dial_ctl_                      206            08/21/20     MR12.7^L
11905 
11906 
11907      Time:     While system is running.
11908 
11909      Meaning:  A system administrator had  enabled tracing of the
11910                dial_ctl_ program.   Many status messages  will be
11911                logged and printed on the console.
11912 
11913      Action:   No operator action is required.
11914 
11915 
11916                [dial_ctl_.pl1]
11917                DIALIN  {PERSON1.PROJECT1}  CHANNEL  to  QUALIFIER
11918                {PERSON2.PROJECT2}
11919 
11920 
11921      Stream:   as (severity0)
11922 
11923      Time:     While system is running.
11924 
11925      Meaning:  A  user on  channel  CHANNEL  has used  the "dial"
11926                preaccess  command  to  dial  the  dial  qualifier
11927                QUALIFIER  owned  by   PERSON2.PROJECT2.   If  the
11928                check_acs  "slave_dial"  flags   was  on  for  the
11929                channel,   then  PERSON1.PROJECT1   specifies  the
11930                identified user.
11931 
11932      Action:   No operator action is required.
11933 
11934 
11935                [dial_ctl_.pl1]
11936                DIALIN   DENIED   {PERSON1.PROJECT1}   CHANNEL  to
11937                QUALIFIER {PERSON2.PROJECT2} REASON
11938 
11939 
11940      Stream:   as (severity0)
11941 
11942      Time:     While system is running.
11943 
11944      Meaning:  A  user on  channel CHANNEL  attempted to  use the
11945                "dial"  preaccess command   to dial  to QUALIFIER,
11946                owned   by  PERSON2.PROJECT2.   The   attempt  was
11947                rejected  for REASON.    If the  channel check_acs
11948                "slave_dial"  flag was  on, then  PERSON1.PROJECT1
11949                specifies the identified user on this channel.
11950 
11951      Action:   Note for system programmer action.
11952 
11953 
11954                [dialup_.pl1]
11955                dialup_:    answer   table    damaged   at   UTEP,
11956                tra_vec=TTTT
11957 
11958 
11959      Stream:   as (severity 2)
11960 
11961 
11962 dialup_                        207            08/21/20     MR12.7^L
11963 
11964 
11965      Time:     While system is running.
11966 
11967      Meaning:  The tra_vec  value was found to be  invalid for an
11968                answer table  wakeup.  Damage to the  answer table
11969                is indicated.
11970 
11971      Action:   Contact the system programming staff.
11972 
11973 
11974                [dialup_.pl1]
11975                dialup_:  called while ansp = null
11976 
11977 
11978      Stream:   as (severity 2)
11979 
11980      Time:     While system is running.
11981 
11982      Meaning:  A programming error in the Answering Service or an
11983                incorrect  library  installation  has  caused  the
11984                Answering  Service  to   be  called  before  being
11985                initialized.  The system will ignore the error and
11986                attempt to continue.
11987 
11988      Action:   Shut  down  the  system  and  perform  a  bootload
11989                operation.
11990 
11991 
11992                [dialup_.pl1]
11993                dialup_:   called with   bad ptr  EVENT_MSG_PTR by
11994                WWWWWWWWWWWW
11995 
11996 
11997      Stream:   as (severity 2)
11998 
11999      Time:     While system is running.
12000 
12001      Meaning:  A   programming   error    in   the   interprocess
12002                communication system, the network software, or the
12003                Answering Service itself has occurred.  An invalid
12004                message pointer  has been passed to  the Answering
12005                Service.   The  system  ignores  the  message  and
12006                attempts  to continue.   This message  may be  the
12007                result of an incorrect library installation.
12008 
12009      Action:   Shut  down  the  system  and  perform  a  bootload
12010                operation.
12011 
12012 
12013                [dialup_.pl1]
12014                dialup_:  called with null message ptr
12015 
12016 
12017      Stream:   as (severity 2)
12018 
12019 
12020 dialup_                        208            08/21/20     MR12.7^L
12021 
12022 
12023      Time:     While system is running.
12024 
12025      Meaning:  A   programming   error    in   the   interprocess
12026                communication system, the network software, or the
12027                Answering Service itself has occurred.  An invalid
12028                message pointer  has been passed to  the Answering
12029                Service.   The  system  ignores  the  message  and
12030                attempts  to continue.   This message  may be  the
12031                result of an incorrect library installation.
12032 
12033      Action:   Shut  down  the  system  and  perform  a  bootload
12034                operation.  Inform the system programming staff.
12035 
12036 
12037 
12038                [dialup_.pl1]
12039                dialup_:     cancelling    inactivity    bump   of
12040                PERSON.PROJECT
12041 
12042 
12043      Stream:   as (severity 1)
12044 
12045      Time:     While system is running.
12046 
12047      Meaning:  This  is  a  logging  message  indicating that the
12048                PERSON.PROJECT  process that  had been  previously
12049                bumped due  to inactivity has become  active.  The
12050                automatic  logout  was  therefore  cancelled.  The
12051                user will receive a message to this effect.
12052 
12053      Action:   No operator action is required.
12054 
12055 
12056                [dialup_.pl1]
12057                dialup_:  CDT damaged at CDTEP, tra_vec=TTTT
12058 
12059 
12060      Stream:   as (severity 2)
12061 
12062      Time:     While system is running.
12063 
12064      Meaning:  The tra_vec  value was found  to be invalid  for a
12065                channel wakeup.  Damage to the CDT is indicated.
12066 
12067      Action:   Contact the system programming staff.
12068 
12069 
12070                [dialup_.pl1]
12071                dialup_:  cdte CDTEP (CHANNEL) state  M in use N -
12072                notify system programmer",
12073 
12074 
12075      Stream:   as (severity 0)
12076 
12077 
12078 dialup_                        209            08/21/20     MR12.7^L
12079 
12080 
12081      Time:     While system is running.
12082 
12083      Meaning:  This indicates a logic error in the supervisor, or
12084                CPU or memory hardware problems.
12085 
12086      Action:   Contact the system programming staff.
12087 
12088 
12089                [dialup_.pl1]
12090                dialup_:  cdtep  = null and ate.active  = DDDD for
12091                UTEP
12092 
12093 
12094      Stream:   as (severity 2)
12095 
12096      Time:     While system is running.
12097 
12098      Meaning:  This indicates a logic error in the supervisor, or
12099                CPU or memory hardware problems.
12100 
12101      Action:   Contact the system programming staff.
12102 
12103 
12104                [dialup_.pl1]
12105                dialup_:    channel_error  called  with   cdte  in
12106                functional state.
12107 
12108 
12109      Stream:   as (severity 1)
12110 
12111      Time:     While system is running.
12112 
12113      Meaning:  This indicates a logic error in the supervisor, or
12114                CPU or memory hardware problems.
12115 
12116      Action:   Contact the system programming staff.
12117 
12118 
12119                [dialup_.pl1]
12120                dialup_:  error - event calls were masked
12121 
12122 
12123      Stream:   as (severity 1)
12124 
12125      Time:     While system is running.
12126 
12127      Meaning:  This  message  indicates  a  serious  error in the
12128                Initializer  programs.   The  system  attempts  to
12129                recover and keep running.
12130 
12131      Action:   Contact the system programming staff.
12132 
12133 
12134 
12135 
12136 dialup_                        210            08/21/20     MR12.7^L
12137 
12138 
12139                [dialup_.pl1]
12140                dialup_:   ERROR_MESSAGE Getting  pointer to  help
12141                file, SYS_DIR>ENTRY_NAME
12142 
12143 
12144      Stream:   as (severity 2)
12145 
12146      Time:     While system is running.
12147 
12148      Meaning:  An ERROR_MESSAGE was returned  when an attempt was
12149                made  to  find   the  login_help  or  connect_help
12150                segment in the SYS_DIR, usually >sc1.
12151 
12152      Action:   Contact the system programming staff.
12153 
12154 
12155                [dialup_.pl1]
12156                dialup_:  ERROR_MESSAGE  setting new tty  info for
12157                CHANNEL
12158 
12159 
12160      Stream:   as (severity 0)
12161 
12162      Time:     While system is running.
12163 
12164      Meaning:  An  ERROR_MESSAGE  was  returned   by  a  call  to
12165                cpg_$set_pit_tty_info  when  setting  new terminal
12166                attributes  in a   reconnected process  on channel
12167                CHANNEL.
12168 
12169      Action:   Contact the system programming staff.
12170 
12171 
12172                [dialup_.pl1]
12173                dialup_:  ERROR_MESSAGE Unable  to declare handler
12174                for ev chn EVENT_CHN for ate UTEP for CDT_CHANNEL
12175 
12176 
12177      Stream:   as (severity 2)
12178 
12179      Time:     While system is running.
12180 
12181      Meaning:  An ERROR_MESSAGE was returned  when an attempt was
12182                made  to declare  an  event  call channel  for new
12183                process   (UTEP)   on    EVENT_CHN   attached   to
12184                CDT_CHANNEL.
12185 
12186      Action:   Contact the system programming staff.
12187 
12188 
12189                [dialup_.pl1]
12190                dialup_:   ERROR_MESSAGE attempting to  allocate a
12191                user table entry for CHANNEL
12192 
12193 
12194 dialup_                        211            08/21/20     MR12.7^L
12195 
12196 
12197      Stream:   as (severity 1)
12198 
12199      Time:     While system is running.
12200 
12201      Meaning:  An  ERROR_MESSAGE  was  returned  from  a  call to
12202                asu_$attach_ate  which  allocates   a  user  table
12203                entry.
12204 
12205      Action:   Contact the system programming staff.
12206 
12207 
12208                [dialup_.pl1]
12209                dialup_:    ERROR_MESSAGE  creating   process  for
12210                PERSON.PROJECT
12211 
12212 
12213      Stream:   as (severity 2)
12214 
12215      Time:     While system is running.
12216 
12217      Meaning:  An ERROR_MESSAGE  was returned and the  system was
12218                unable    to   create    a   user    process   for
12219                PERSON.PROJECT.
12220 
12221      Action:   If possible, get in touch  with the user.  (He got
12222                a message  to contact you.)  Ask him  to try again
12223                and to tell you of any peculiarities of his login.
12224                Note all  particulars and contact  the programming
12225                staff.
12226 
12227 
12228 
12229                [dialup_.pl1]
12230                dialup_:  ERROR_MESSAGE From write_status order on
12231                CHANNEL
12232 
12233 
12234      Stream:   as (severity 1)
12235 
12236      Time:     While system is running.
12237 
12238      Meaning:  This is a debugging  message that will only appear
12239                if tracing has been  enabled.  An ERROR_MESSAGE by
12240                a call  to astty_$tty_order with  a "write_status"
12241                order.
12242 
12243      Action:   Contact the system programming staff.
12244 
12245 
12246                [dialup_.pl1]
12247                dialup_:   ERROR_MESSAGE get_required_access_class
12248                order failed for CHANNEL
12249 
12250 
12251 
12252 dialup_                        212            08/21/20     MR12.7^L
12253 
12254 
12255      Stream:   as (severity 1)
12256 
12257      Time:     While system is running.
12258 
12259      Meaning:  An  ERROR_MESSAGE  was  returned   by  a  call  to
12260                astty_$tty_order with  a get_required_access_class
12261                order for CHANNEL.  The channel will be hungup.
12262 
12263      Action:   Contact the system programming staff._ssa
12264 
12265 
12266                [dialup_.pl1]
12267                dialup_:    ERROR_MESSAGE   ttt   error,  removing
12268                channel CHANNEL COMMENT
12269 
12270 
12271      Stream:   as (severity 2)
12272 
12273      Time:     While system is running.
12274 
12275      Meaning:  An ERROR_MESSAGE resulting  from accessing the TTT
12276                has caused the CHANNEL with COMMENT to be unusable
12277                when attempting  to set the default  terminal type
12278                based  on  line-type/baud-rate.   The  channel has
12279                been removed from known channels.
12280 
12281      Action:   Contact the  system programming staff.   An attach
12282                of the CHANNEL can be tried.  If the channel is to
12283                be left detached, busy out the modem.
12284 
12285 
12286 
12287                [dialup_.pl1]
12288                dialup_:   ERROR_MESSAGE  tty_dim  error, removing
12289                channel CHANNEL COMMENT
12290 
12291 
12292      Stream:   as (severity 2)
12293 
12294      Time:     While system is running.
12295 
12296      Meaning:  An   ERROR_MESSAGE  caused   the  CHANNEL   to  be
12297                unusable.   The  CHANNEL   with  COMMENT  will  be
12298                removed from service.
12299 
12300      Action:   You may try to attach the channel.  If that fails,
12301                notify the system programmers.   If the channel is
12302                to be left detached, busy out the modem.
12303 
12304 
12305 
12306                [dialup_.pl1]
12307 
12308 
12309 
12310 dialup_                        213            08/21/20     MR12.7^L
12311 
12312 
12313                dialup_:  ERROR_MESSAGE when  attempting to notify
12314                user PERSON.PROJECT of dialup event
12315 
12316 
12317      Stream:   as (severity 0)
12318 
12319      Time:     While system is running.
12320 
12321      Meaning:  An ERROR_MESSAGE was returned  when an attempt was
12322                made to  send a message to  PERSON.PROJECT about a
12323                dialup event.
12324 
12325      Action:   Contact the system programming staff.
12326 
12327 
12328                [dialup_.pl1]
12329                dialup_:  ERROR_MESSAGE.  Trying to wakeup process
12330                after reconnection for PERSON.PROJECT.TAG
12331 
12332 
12333 
12334      Stream:   as (severity 0)
12335 
12336      Time:     Called  in response to  a user reconnecting  to an
12337                interactive process.
12338 
12339      Meaning:  A failure  occurred while sending a  wakeup to the
12340                process   being   connected   to   the   terminal.
12341                ERROR_MESSAGE  is  the  text  associated  with the
12342                error code returned by hcs_$wakeup.
12343 
12344      Action:   No operator action is required.
12345 
12346 
12347                [dialup_.pl1]
12348                dialup_:  fatal error  during process creation for
12349                PERSON.PROJECT CHANNEL
12350 
12351 
12352      Stream:   as (severity 1)
12353 
12354      Time:     While system is running.
12355 
12356      Meaning:  A fatal error occurred during process creation for
12357                PERSON.PROJECT  on CHANNEL.    Reason is  given in
12358                previous  log entry.   This may  be due  to a user
12359                error:   incorrect  segments  in  the  user's home
12360                directory  or bad  login arguments  can cause this
12361                problem.
12362 
12363      Action:   No operator action is required.
12364 
12365 
12366 
12367 
12368 dialup_                        214            08/21/20     MR12.7^L
12369 
12370 
12371                [dialup_.pl1]
12372                dialup_:      ignored     SSSS     for     CHANNEL
12373                st=DDDD,inuse=UUUU,tv=TTTT
12374 
12375 
12376      Stream:   as (severity 2)
12377 
12378      Time:     While system is running.
12379 
12380      Meaning:  A  spurious signal  SSSS has  arrived for CHANNEL.
12381                The state of the channel is DDD, inuse is UUUU and
12382                tra_vec is TTTT.
12383 
12384      Action:   This  may